Nanostructured electrodes for biocompatible CMOS integrated circuits

被引:10
作者
Graham, Anthony H. D. [1 ]
Bowen, Chris R. [2 ]
Robbins, Jon [3 ]
Lalev, Georgi [4 ]
Marken, Frank [5 ]
Taylor, John [1 ]
机构
[1] Univ Bath, Dept Elect & Elect Engn, Bath BA2 7AY, Avon, England
[2] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
[3] Kings Coll London, Receptors & Signalling Wolfson CARD, Higher Educ Acad Teaching Practice, London SE1 1UL, England
[4] Cardiff Univ, Mfg Engn Ctr, Nanomfg Technol Lab, Cardiff CF24 3AA, S Glam, Wales
[5] Univ Bath, Dept Chem, Bath BA2 7AY, Avon, England
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2010年 / 147卷 / 02期
基金
英国工程与自然科学研究理事会;
关键词
Electrode; CMOS; Anodic aluminum oxide (AAO); Biocompatibility; Impedance; Biosensor; POROUS ANODIC ALUMINA; PULSED ELECTRODEPOSITION; NANOWIRE ARRAYS; BARRIER LAYER; CU ALLOY; SILICON; GROWTH; OXIDE; FABRICATION; TEMPLATE;
D O I
10.1016/j.snb.2010.03.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports on the adaptation of standard complementary metal oxide semiconductor (CMOS) integrated circuit (IC) technology for biocompatibility, enabling a low-cost solution for drug discovery pharmacology, neural interface systems, cell-based biosensors and electrophysiology. The basis for the process is the anodisation of IC aluminium electrodes to form nanoporous alumina. The porous alumina was electrochemically thinned to reduce the alumina electrode impedance. For applications where a porous electrode surface is either preferred or acceptable, we demonstrated that porosity can be manipulated at room temperature by modifying the anodising electrolyte to include up to 40% polyethylene glycol and reducing the phosphoric acid concentration from 4% (w/v) to 1%. For applications requiring a planar microelectrode surface, a noble metal was electrodeposited into the pores of the alumina film. Limited success was achieved with a pH 7 platinum and pH 5 gold cyanide bath but good results were demonstrated with a pH 0.5 gold chloride bath which produced planar biocompatible electrodes. A further reduction in impedance was produced by deposition of platinum-black, which may be a necessary additional step for demanding applications such as neuronal recording. During this work a capability for real-time electrochemical impedance spectroscopy (EIS) was developed to study anodisation, barrier oxide thinning, oxide breakdown and electrodeposition processes. To study the pore morphology, focused ion beam (FIB) was employed to produce cross-sectional cuts of the IC features which were inspected by SEM with an 'In-lens' detector. The anodisation process and the optional electrodeposition steps require only simple bench equipment operated at room temperature and is therefore a viable route for manufacturing low-cost biocompatible electrodes from standard CMOS ICs. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:697 / 706
页数:10
相关论文
共 50 条
  • [21] Light Emitting Devices in Si CMOS and RF Bipolar Integrated Circuits
    Xu, Kaikai
    Ogudo, Kingsley A.
    Polleux, Jean-Luc
    Viana, Carlos
    Ma, Zhengfei
    Li, Zebin
    Yu, Qi
    Li, Guannpyng
    Snyman, Lukas W.
    LEUKOS, 2016, 12 (04) : 203 - 212
  • [22] Bendable CMOS Digital and Analog Circuits Monolithically Integrated with a Temperature Sensor
    Honda, Wataru
    Arie, Takayuki
    Akita, Seiji
    Takei, Kuniharu
    ADVANCED MATERIALS TECHNOLOGIES, 2016, 1 (05):
  • [23] Implementation of CMOS fuzzy controllers as mixed-signal integrated circuits
    Baturone, I
    SanchezSolano, S
    Barriga, A
    Huertas, JL
    IEEE TRANSACTIONS ON FUZZY SYSTEMS, 1997, 5 (01) : 1 - 19
  • [24] Laser attacks on integrated circuits: from CMOS to FD-SOI
    Dutertre, Jean-Max
    De Castro, Stephan
    Sarafianos, Alexandre
    Boher, Noemie
    Rouzeyre, Bruno
    Lisart, Mathieu
    Damiens, Joel
    Candelier, Philippe
    Flottes, Marie-Lise
    Di Natale, Giorgio
    2014 9TH IEEE INTERNATIONAL CONFERENCE ON DESIGN & TECHNOLOGY OF INTEGRATED SYSTEMS IN NANOSCALE ERA (DTIS 2014), 2014,
  • [25] Millimeter-wave integrated circuits in 65-nm CMOS
    Varonen, Mikko
    Karkkainen, Mikko
    Kantanen, Mikko
    Halonen, Kari A. I.
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2008, 43 (09) : 1991 - 2002
  • [26] Review of CMOS Millimeter-wave Radio Frequency Integrated Circuits
    Wang, Huei
    2015 IEEE MTT-S INTERNATIONAL MICROWAVE AND RF CONFERENCE (IMARC), 2015, : 239 - 242
  • [27] Flexible CMOS integrated circuits based on carbon nanotubes with sub-10 ns stage delays
    Tang, Jianshi
    Cao, Qing
    Tulevski, George
    Jenkins, Keith A.
    Nela, Luca
    Farmer, Damon B.
    Han, Shu-Jen
    NATURE ELECTRONICS, 2018, 1 (03): : 191 - 196
  • [28] Phase-Change Nanophotonic Circuits With Crossbar Electrodes and Integrated Microheaters
    Lian, Xiaojuan
    Jiang, Jiyuan
    Fu, Jinke
    Wan, Xiang
    Liu, Xiaoyan
    Cai, Zhikuang
    Wang, Lei
    IEEE ELECTRON DEVICE LETTERS, 2022, 43 (12) : 2192 - 2195
  • [29] Integrated Bias Circuits of RF CMOS Cascode Power Amplifier for Linearity Enhancement
    Koo, Bonhoon
    Na, Yoosam
    Hong, Songcheol
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2012, 60 (02) : 340 - 351
  • [30] Confocal imaging by turning antennas with CMOS integrated circuits for breast cancer detection
    Song, Hang
    Kono, Hayato
    Seo, Yuji
    Azhari, Afreen
    Xiao, Xia
    Kikkawa, Takamaro
    2016 INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP), 2016, : 920 - 921