Image quality of conventional images of dual-layer SPECTRAL CT: A phantom study

被引:31
|
作者
van Ommen, Fasco [1 ,2 ]
Bennink, Edwin [1 ,2 ]
Vlassenbroek, Alain [3 ]
Dankbaar, Jan Willem [1 ]
Schilham, Arnold M. R. [1 ]
Viergever, Max A. [2 ]
de Jong, Hugo W. A. M. [1 ,2 ]
机构
[1] UMC Utrecht, Radiol & Nucl Med, POB 85500, NL-3508 GA Utrecht, Netherlands
[2] UMC Utrecht, Image Sci Inst, POB 85500, NL-3508 GA Utrecht, Netherlands
[3] Philips Healthcare, CT Clin Sci, Brussels, Belgium
关键词
conventional images; dual-energy CT; dual-layer detector; image-quality; Spectral CT; ITERATIVE RECONSTRUCTION ALGORITHMS; COMPUTED-TOMOGRAPHY; DETECTOR CT;
D O I
10.1002/mp.12959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeSpectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips Healthcare) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips Healthcare), by means of phantom experiments. MethodsFor both CT scanners, conventional CT images were acquired using four adult scanning protocols: (a) body helical, (b) body axial, (c) head helical, and (d) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. ResultsThe resolution levels at 50%, 10%, and 5% MTF of the iCT and IQon showed small, but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with differences up to 0.51. Spatial resolution did not change with phantom size, but noise levels increased significantly. For head scans, IQon had a noise level that was significantly lower than the iCT, on the other hand IQon showed noise levels significantly higher than the iCT for body scans. Still, these differences were well within the specified range of performance of iCT scanners. ConclusionsAt equivalent dose levels, this study showed similar quality of conventional images acquired on iCT and IQon for medium-sized phantoms and slightly degraded image quality for (very) large phantoms at lower tube voltages on the IQon. Accordingly, it may be concluded that the introduction of a dual-layer detector neither compromises image quality of conventional images nor increases radiation dose for normal-sized patients, and slightly degrades dose efficiency for large patients at 120 kVp and lower tube voltages.
引用
收藏
页码:3031 / 3042
页数:12
相关论文
共 50 条
  • [31] Principles and Applications of Dual-Layer Spectral CT in Gastrointestinal Imaging
    Franco, Paolo Niccolo
    Spasiano, Chiara Maria
    Maino, Cesare
    De Ponti, Elena
    Ragusi, Maria
    Giandola, Teresa
    Terrani, Simone
    Peroni, Marta
    Corso, Rocco
    Ippolito, Davide
    DIAGNOSTICS, 2023, 13 (10)
  • [32] Ultra-low dose dual-layer detector spectral CT for pulmonary nodule screening: image quality and diagnostic performance
    Ding, Li
    Chen, Mingwang
    Li, Xiaomei
    Wu, Yuting
    Li, Jingxu
    Deng, Shuting
    Xu, Yikai
    Chen, Zhao
    Yan, Chenggong
    INSIGHTS INTO IMAGING, 2025, 16 (01):
  • [33] Improvement of Image Quality in Unenhanced Dual-Layer CT of the Head Using Virtual Monoenergetic Images Compared With Polyenergetic Single-Energy CT
    Neuhaus, Victor
    Abdullayev, Nuran
    Hokamp, Nils Grosse
    Pahn, Gregor
    Kabbasch, Christoph
    Mpotsaris, Anastasios
    Maintz, David
    Borggrefe, Jan
    INVESTIGATIVE RADIOLOGY, 2017, 52 (08) : 470 - 476
  • [34] Utilisation of virtual non-contrast images and virtual mono-energetic images acquired from dual-layer spectral CT for renal cell carcinoma: image quality and radiation dose
    Zhang, Xiaoxiao
    Zhang, Gumuyang
    Xu, Lili
    Bai, Xin
    Lu, Xiaomei
    Yu, Shenghui
    Sun, Hao
    Jin, Zhengyu
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [35] Utilisation of virtual non-contrast images and virtual mono-energetic images acquired from dual-layer spectral CT for renal cell carcinoma: image quality and radiation dose
    Xiaoxiao Zhang
    Gumuyang Zhang
    Lili Xu
    Xin Bai
    Xiaomei Lu
    Shenghui Yu
    Hao Sun
    Zhengyu Jin
    Insights into Imaging, 13
  • [36] The Application of Dual-layer Spectral Detector CT in Abdominal Vascular Imaging
    Lai, Lu-Yao
    Jiang, Ying
    Shu, Jian
    CURRENT MEDICAL IMAGING, 2023, 19 (14) : 1609 - 1615
  • [37] Noninvasive assessment of liver fibrosis by dual-layer spectral detector CT
    Morita, Koichiro
    Nishie, Akihiro
    Ushijima, Yasuhiro
    Takayama, Yukihisa
    Fujita, Nobuhiro
    Kubo, Yuichiro
    Ishimatsu, Keisuke
    Yoshizumi, Tomoharu
    Maehara, Junki
    Ishigami, Kousei
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136
  • [38] Improvement of Breast Cancer Detection Using Dual-Layer Spectral CT
    Hasse, Felix Christian
    Giannakis, Athanasios
    Wehrse, Eckhard
    Stiller, Wolfram
    Wallwiener, Markus
    Kauczor, Hans-Ulrich
    Weber, Tim F.
    Heil, Jorg
    Mokry, Theresa
    DIAGNOSTICS, 2024, 14 (14)
  • [39] Acute infarction after mechanical thrombectomy is better delineable in virtual non-contrast compared to conventional images using a dual-layer spectral CT
    Riederer, Isabelle
    Fingerle, Alexander A.
    Baum, Thomas
    Kirschke, Jan S.
    Rummeny, Ernst J.
    Noel, Peter B.
    Pfeiffer, Daniela
    SCIENTIFIC REPORTS, 2018, 8
  • [40] Acute infarction after mechanical thrombectomy is better delineable in virtual non-contrast compared to conventional images using a dual-layer spectral CT
    Isabelle Riederer
    Alexander A. Fingerle
    Thomas Baum
    Jan S. Kirschke
    Ernst J. Rummeny
    Peter B. Noël
    Daniela Pfeiffer
    Scientific Reports, 8