Image quality of conventional images of dual-layer SPECTRAL CT: A phantom study

被引:31
|
作者
van Ommen, Fasco [1 ,2 ]
Bennink, Edwin [1 ,2 ]
Vlassenbroek, Alain [3 ]
Dankbaar, Jan Willem [1 ]
Schilham, Arnold M. R. [1 ]
Viergever, Max A. [2 ]
de Jong, Hugo W. A. M. [1 ,2 ]
机构
[1] UMC Utrecht, Radiol & Nucl Med, POB 85500, NL-3508 GA Utrecht, Netherlands
[2] UMC Utrecht, Image Sci Inst, POB 85500, NL-3508 GA Utrecht, Netherlands
[3] Philips Healthcare, CT Clin Sci, Brussels, Belgium
关键词
conventional images; dual-energy CT; dual-layer detector; image-quality; Spectral CT; ITERATIVE RECONSTRUCTION ALGORITHMS; COMPUTED-TOMOGRAPHY; DETECTOR CT;
D O I
10.1002/mp.12959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeSpectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips Healthcare) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips Healthcare), by means of phantom experiments. MethodsFor both CT scanners, conventional CT images were acquired using four adult scanning protocols: (a) body helical, (b) body axial, (c) head helical, and (d) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. ResultsThe resolution levels at 50%, 10%, and 5% MTF of the iCT and IQon showed small, but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with differences up to 0.51. Spatial resolution did not change with phantom size, but noise levels increased significantly. For head scans, IQon had a noise level that was significantly lower than the iCT, on the other hand IQon showed noise levels significantly higher than the iCT for body scans. Still, these differences were well within the specified range of performance of iCT scanners. ConclusionsAt equivalent dose levels, this study showed similar quality of conventional images acquired on iCT and IQon for medium-sized phantoms and slightly degraded image quality for (very) large phantoms at lower tube voltages on the IQon. Accordingly, it may be concluded that the introduction of a dual-layer detector neither compromises image quality of conventional images nor increases radiation dose for normal-sized patients, and slightly degrades dose efficiency for large patients at 120 kVp and lower tube voltages.
引用
收藏
页码:3031 / 3042
页数:12
相关论文
共 50 条
  • [1] Image quality evaluation of dual-layer spectral detector CT of the chest and comparison with conventional CT imaging
    Doerner, Jonas
    Hauger, Myriam
    Hickethier, Tilman
    Byrtus, Jonathan
    Wybranski, Christian
    Hokamp, Nils Grosse
    Maintz, David
    Haneder, Stefan
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 52 - 58
  • [2] Comparison of image quality between spectral photon-counting CT and dual-layer CT for the evaluation of lung nodules: a phantom study
    Si-Mohamed, Salim A.
    Greffier, Joel
    Miailhes, Jade
    Boccalini, Sara
    Rodesch, Pierre-Antoine
    Vuillod, Aurelie
    van der Werf, Niels
    Dabli, Djamel
    Racine, Damien
    Rotzinger, David
    Becce, Fabio
    Yagil, Yoad
    Coulon, Philippe
    Vlassenbroek, Alain
    Boussel, Loic
    Beregi, Jean-Paul
    Douek, Philippe
    EUROPEAN RADIOLOGY, 2022, 32 (01) : 524 - 532
  • [3] Comparison of image quality between spectral photon-counting CT and dual-layer CT for the evaluation of lung nodules: a phantom study
    Salim A. Si-Mohamed
    Joel Greffier
    Jade Miailhes
    Sara Boccalini
    Pierre-Antoine Rodesch
    Aurélie Vuillod
    Niels van der Werf
    Djamel Dabli
    Damien Racine
    David Rotzinger
    Fabio Becce
    Yoad Yagil
    Philippe Coulon
    Alain Vlassenbroek
    Loic Boussel
    Jean-Paul Beregi
    Philippe Douek
    European Radiology, 2022, 32 : 524 - 532
  • [4] Image quality characteristics for virtual monoenergetic images using dual-layer spectral detector CT: Comparison with conventional tube-voltage images
    Sakabe, Daisuke
    Funama, Yoshinori
    Taguchi, Katsuyuki
    Nakaura, Takeshi
    Utsunomiya, Daisuke
    Oda, Seitaro
    Kidoh, Masafumi
    Nagayama, Yasunori
    Yamashita, Yasuyuki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 49 : 5 - 10
  • [5] Dual-layer spectral CT improves the image quality of cerebral unenhanced CT scan in children
    Tan, Zhengwu
    Zhang, Lan
    Sun, Xiaojie
    Yang, Ming
    Wu, Hongying
    Wang, Jing
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 164
  • [6] Improved Sensitivity and Reader Confidence in CT Colonography Using Dual-Layer Spectral CT: A Phantom Study
    Obmann, Markus M.
    An, Chansik
    Schaefer, Amanda
    Sun, Yuxin
    Wang, Zhen J.
    Yee, Judy
    Yeh, Benjamin M.
    RADIOLOGY, 2020, 297 (01) : 99 - 107
  • [7] Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom
    Hyo-Jin Kang
    Jeong Min Lee
    Sang Min Lee
    Hyun Kyung Yang
    Ri Hyeon Kim
    Ju Gang Nam
    Aruna Karnawat
    Joon Koo Han
    BMC Medical Imaging, 19
  • [8] Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom
    Kang, Hyo-Jin
    Lee, Jeong Min
    Lee, Sang Min
    Yang, Hyun Kyung
    Kim, Ri Hyeon
    Nam, Ju Gang
    Karnawat, Aruna
    Han, Joon Koo
    BMC MEDICAL IMAGING, 2019, 19 (01)
  • [9] Objective Image Characterization of Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Halliburton, S.
    Dhanantwari, A.
    Wen, G.
    Utrup, S.
    Jordan, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3836 - 3836
  • [10] A Technique to Identify Isoattenuating Gallstones with Dual-Layer Spectral CT: An ex Vivo Phantom Study
    Soesbe, Todd C.
    Lewis, Matthew A.
    Xi, Yin
    Browning, Travis
    Ananthakrishnan, Lakshmi
    Fielding, Julia R.
    Lenkinski, Robert E.
    Leyendecker, John R.
    RADIOLOGY, 2019, 292 (02) : 400 - 406