Heart rate and blood pressure variability in patients implanted with rate-responsive pacemaker

被引:0
作者
Censi, F [1 ]
Calcagnini, G [1 ]
D'Alessandro, A [1 ]
Malavasi, A [1 ]
Quaglione, R [1 ]
Critelli, G [1 ]
Bartolini, P [1 ]
Barbaro, V [1 ]
机构
[1] Ist Super Sanita, Dept Technol & Hlth, Rome, Italy
来源
PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7 | 2004年 / 26卷
关键词
cardiovascular signal processing; heart rate variability; rate responsive pacemakers;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Rate-responsive pacemakers (PMs) aim at having pacing rates as similar to physiological cardiac rhythms as possible. The pacemaker INOS2+-CLS (Biotronik, Germany) implements a closed loop strategy (CLS) based on indirect measures of right ventricle contractility using intracardiac impedance signal. The contractility is, in turn, related to the autonomic nervous system control to the heart. Aim of this study was to evaluate the 24h beat-to-beat heart rate and blood pressure profiles in patients implanted with CLS rate adaptive PM. 24h ECG and arterial pressure waveform acquisition were performed by a digital HOLTER system by the Portapres equipment, respectively. A proper-designed algorithm was developed to classify PM pacing modalities. For each beat we estimated the heart rate (HR), and the systolic and diastolic pressure values (SP, DP). So far, 6 patients have been studied: 4 patients have been analyzed both with and without rate responsive modalities (DDD-R and DDD, respectively); 2 patients have been studied only with rate-responsive modality. Results obtained in 6 patients show that this rate adaptive PM accurately preserve the heart rate and blood pressure variability throughout the 24h. In particular, the rate adaptation of PM based on impedance measurements succeeds in maintaining the spontaneous HR, SP and DP on a beat-to-beat basis.
引用
收藏
页码:3949 / 3952
页数:4
相关论文
共 10 条
[1]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[2]   Interindividual comparison of different sensor principles for rate adaptive pacing [J].
Malinowski, K .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2209-2213
[3]  
MENEZES AS, 1999, PROGR BIOMEDICAL RES, P190
[4]   A REAL-TIME QRS DETECTION ALGORITHM [J].
PAN, J ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (03) :230-236
[5]   AUTONOMIC NERVOUS-SYSTEM CONTROLLED CLOSED-LOOP CARDIAC PACING [J].
PICHLMAIER, AM ;
BRAILE, D ;
EBNER, E ;
GRECO, OT ;
HUTTEN, H ;
VONKNORRE, GH ;
NIEDERLAG, W ;
RENTSCH, W ;
VOLKMANN, H ;
WEBER, D ;
WUNDERLICH, E ;
SCHALDACH, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1787-1791
[6]   Effect of autonomic stressors on rate control in pacemakers using ventricular impedance signal [J].
Santini, M ;
Ricci, R ;
Pignalberi, C ;
Biancalana, G ;
Censi, F ;
Calcagnini, G ;
Bartolini, P ;
Barbaro, V .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (01) :24-32
[7]   AUTOMATIC ADJUSTMENT OF PACING PARAMETERS BASED ON INTRACARDIAC IMPEDANCE MEASUREMENTS [J].
SCHALDACH, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12) :1702-1710
[8]  
SCHALDACH M, 1988, BIOMED TECH, V33, P286
[9]   INTRACARDIAC IMPEDANCE TO DETERMINE SYMPATHETIC ACTIVITY IN RATE RESPONSIVE PACING [J].
SCHALDACH, M ;
HUTTEN, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1778-1786
[10]   A NEW MULTISENSOR PACING SYSTEM USING STROKE VOLUME, RESPIRATORY RATE, MIXED VENOUS OXYGEN-SATURATION, AND TEMPERATURE, RIGHT ATRIAL PRESSURE, RIGHT VENTRICULAR PRESSURE, AND DP DT [J].
STANGL, K ;
WIRTZFELD, A ;
HEINZE, R ;
LAULE, M ;
SEITZ, K ;
GOBL, G .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (06) :712-724