A comparison of Monte-Carlo simulated and measured dose distributions in oblique electron beams

被引:1
作者
Schweizer, Frederic [1 ]
Christ, Gunter [1 ]
机构
[1] Univ Klinikum Tubingen, Klin Radioonkol, D-72076 Tubingen, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2010年 / 20卷 / 01期
关键词
Electron beams; oblique incidence; treatment planning; Monte-Carlo algorithms;
D O I
10.1016/j.zemedi.2009.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Oblique incidence of electron beams is a rare clinical application which can be used e.g. at the irradiation of the internal mammary lymph nodes in the case of mamma carcinoma. 3-D treatment planning systems are accepted standard for photon beams but not for electron beams. The in for measuring, implementing and testing basic data seems many customers not to be worthwhile when considering the well known inaccuracies of conventional algorithms. From Monte-Carlo (MC) based algorithms however higher accuracies can be expected. It was the aim of this paper to test the MC algorithm of the treatment planning system Oncentra Treatment Planning (OTP, Theranostic) in the application for oblique incidence of electron beams. Measured and simulated values are compared for electron energies from 4 MeV up to 18 Me V. For standard electron applicators, even at extended source-surface distances, satisfying results are achieved. However, the agreement gets lost with increasing oblique incidence, especially for small individual and asymmetrical cut outs. We therefore still use measured values instead of simulated dose distributions.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 37 条
  • [31] A virtual-acceterator-based verification of a Monte Carlo dose calculation algorithm for electron beam treatment planning in clinical situations
    Wieslander, Elinore
    Knoos, Tommy
    RADIOTHERAPY AND ONCOLOGY, 2007, 82 (02) : 208 - 217
  • [32] Practical methods for improving dose distributions in Monte Carlo-based IMRT planning of lung wall-seated tumors treated with SBRT
    Altman, Michael B.
    Jin, Jian-Yue
    Kim, Sangroh
    Wen, Ning
    Liu, Dezhi
    Siddiqui, M. Salim
    Ajlouni, Munther I.
    Movsas, Benjamin
    Chetty, Indrin J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (06): : 112 - 125
  • [33] Exposure dose dependence on line edge roughness of a latent image in electron beam/extreme ultraviolet lithographies studied by Monte Carlo technique
    Saeki, Alkinori
    Kozawa, Takahiro
    Tagawa, Seiichi
    Cao, Heidi B.
    Deng, Hai
    Leeson, Michael J.
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2007, 6 (04):
  • [34] Evaluation of lens dose from anterior electron beams: comparison of Pinnacle and Gafchromic EBT3 film
    Sonier, Marcus
    Wronski, Matt
    Yeboah, Collins
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 304 - 314
  • [35] On the Perturbation Factor P_cav of the Markus Parallel Plate Ion Chambers in Clinical Electron Beams, Monte Carlo Based Reintegration of An Historical Experiment
    von Voigts-Rhetz, P.
    Zink, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 329 - +
  • [36] A comparison of Monte Carlo dropout and bootstrap aggregation on the performance and uncertainty estimation in radiation therapy dose prediction with deep learning neural networks
    Nguyen, Dan
    Sadeghnejad Barkousaraie, Azar
    Bohara, Gyanendra
    Balagopal, Anjali
    McBeth, Rafe
    Lin, Mu-Han
    Jiang, Steve
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05)
  • [37] Comparison of pencil beam-based homogeneous vs inhomogeneous target dose planning for stereotactic body radiotherapy of peripheral lung tumors through Monte Carlo-based recalculation
    Ohtakara, Kazuhiro
    Hoshi, Hiroaki
    MEDICAL DOSIMETRY, 2015, 40 (03) : 248 - 255