Acoustic properties of dialysed kidney by scanning acoustic microscopy

被引:17
|
作者
Sasaki, H [1 ]
Saijo, Y [1 ]
Tanaka, M [1 ]
Nitta, S [1 ]
Terasawa, Y [1 ]
Yambe, T [1 ]
Taguma, Y [1 ]
机构
[1] SENDAI SHAKAIHOKEN HOSP,KIDNEY CTR,SENDAI,MIYAGI,JAPAN
关键词
acoustic microscopy; attenuation constant; sound speed; haemodialysis; renal-cell carcinoma; acquired renal cyst;
D O I
10.1093/ndt/12.10.2151
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background, A correlation between acquired renal cysts in the dialysed kidney and renal cancer has long been debated, but no changes in the physical properties of kidneys at the microscopic level have been reported. The purpose of the present study was to classify the physical properties of the kidneys of patients undergoing haemodialysis at several stages of pathology by use of the scanning acoustic microscope. Methods, Sixteen surgically excised kidneys of dialysis patients were investigated. Tissues were fixed in 10% formalin, frozen in acetone, and cut 10 mu m thick on a cryostat. We used a scanning acoustic microscope operated in the frequency range of 100-200 MHz. Attenuation constant and sound speed were measured on a two-dimensional distribution. Results, The attenuation constant for inflammatory granulation tissue was significantly higher than that for hyaline degeneration tissue (P<0.001). Sound speed was high for granulation tissue, but tended to diminish gradually for hyaline degeneration. Sound speed increased again with progression to cystic degeneration (P<0.001), but the attenuation constant remained low. When a cystic kidney contained a malignant lesion, the previously low attenuation constant rose at that site (P<0.001), and the previously high sound speed was diminished (P<0.001). Conclusion, Our data suggest that the physical properties of dialysed kidneys at different stages of pathology can be classified by their acoustic properties. Simultaneous evaluation of attenuation constant and sound speed is considered applicable to determining whether tissues contain malignant elements.
引用
收藏
页码:2151 / 2154
页数:4
相关论文
共 50 条
  • [1] Acoustic properties of aortic aneurysm obtained with scanning acoustic microscopy
    Saijo, Y
    Miyakawa, T
    Sasaki, H
    Tanaka, M
    Nitta, S
    ULTRASONICS, 2004, 42 (1-9) : 695 - 698
  • [2] Scanning acoustic Doppler microscopy and scanning acoustic correlation microscopy
    Kojro, Z
    Jahny, J
    Kim, TJ
    Ndop, J
    Schmachtl, M
    Grill, W
    ULTRASONICS, 2002, 40 (1-8) : 67 - 71
  • [3] SCANNING ELECTRON ACOUSTIC MICROSCOPY AND SCANNING ACOUSTIC MICROSCOPY - A FAVORABLE COMPARISON
    BRIGGS, GAD
    SCANNING ELECTRON MICROSCOPY, 1984, : 1041 - 1052
  • [4] Acoustic and mechanical properties of aortic aneurysms assessed by scanning acoustic microscopy
    Saijo, Y
    Miyakawa, T
    Sasaki, H
    Tanaka, M
    Nitta, SI
    ACOUSTICAL IMAGING, VOL 27, 2004, 27 : 479 - 483
  • [5] Scanning acoustic microscopy
    Nelson, TM
    Smith, RW
    ADVANCED MATERIALS & PROCESSES, 2004, 162 (12): : 29 - 32
  • [6] SCANNING ACOUSTIC MICROSCOPY
    KHURIYAKUB, BT
    ULTRASONICS, 1993, 31 (05) : 361 - 372
  • [7] SCANNING ACOUSTIC MICROSCOPY
    BALK, LJ
    SURFACE AND INTERFACE ANALYSIS, 1986, 9 (1-6) : 47 - 54
  • [8] SCANNING ELECTRON ACOUSTIC MICROSCOPY
    DAVIES, G
    HOWIE, A
    STAVELEYSMITH, L
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 368 : 58 - 65
  • [9] Scanning acoustic microscopy: SAM
    Gremaud, G.
    2001, Trans Tech Publications Ltd (366-368)
  • [10] Scanning acoustic microscopy: SAM
    Gremaud, G
    MECHANICAL SPECTROSCOPY Q-1 2001, 2001, 366-3 : 676 - 683