Kinematic Analysis of Healthy Hips during Weight-Bearing Activities by 3D-to-2D Model-to-Image Registration Technique

被引:39
作者
Hara, Daisuke [1 ]
Nakashima, Yasuharu [1 ]
Hamai, Satoshi [1 ]
Higaki, Hidehiko [2 ]
Ikebe, Satoru [2 ]
Shimoto, Takeshi [3 ]
Hirata, Masanobu [1 ]
Kanazawa, Masayuki [1 ]
Kohno, Yusuke [1 ]
Iwamoto, Yukihide [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
[2] Kyushu Sangyo Univ, Fac Engn, Dept Med Engn, Higashi Ku, Fukuoka 8130004, Japan
[3] Fukuoka Inst Technol, Fac Engn, Dept Mech Engn, Higashi Ku, Fukuoka 8110295, Japan
基金
日本学术振兴会;
关键词
KNEE-JOINT; 3-DIMENSIONAL MOTION; MOVEMENT; FLUOROSCOPY; GAIT;
D O I
10.1155/2014/457573
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Dynamic hip kinematics during weight-bearing activities were analyzed for six healthy subjects. Continuous X-ray images of gait, chair-rising, squatting, and twisting were taken using a flat panel X-ray detector. Digitally reconstructed radiographic images were used for 3D-to-2D model-to-image registration technique. The root-mean-square errors associated with tracking the pelvis and femur were less than 0.3mm and 0.3 degrees for translations and rotations. For gait, chair-rising, and squatting, the maximum hip flexion angles averaged 29.6 degrees, 81.3 degrees, and 102.4 degrees, respectively. The pelvis was tilted anteriorly around 4.4 degrees on average during full gait cycle. For chair-rising and squatting, the maximum absolute value of anterior/posterior pelvic tilt averaged 12.4 degrees /11.7 degrees and 10.7 degrees/10.8 degrees, respectively. Hip flexion peaked on the way of movement due to further anterior pelvic tilt during both chair-rising and squatting. For twisting, the maximum absolute value of hip internal/external rotation averaged 29.2 degrees /30.7 degrees. This study revealed activity dependent kinematics of healthy hip joints with coordinated pelvic and femoral dynamic movements. Kinematics' data during activities of daily living may provide important insight as to the evaluating kinematics of pathological and reconstructed hips.
引用
收藏
页数:8
相关论文
共 23 条
[1]   Position and orientation in space of bones during movement: Experimental artefacts [J].
Cappozzo, A ;
Catani, F ;
Leardini, A ;
Benedetti, MG ;
DellaCroce, U .
CLINICAL BIOMECHANICS, 1996, 11 (02) :90-100
[2]   Comparison of Pelvic Complex Kinematics During Treadmill and Overground Walking [J].
Chockalingam, Nachiappan ;
Chatterley, Faye ;
Healy, Aoife C. ;
Greenhalgh, Andrew ;
Branthwaite, Helen R. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (12) :2302-2308
[3]   Femoroacetabular impingement -: A cause for osteoarthritis of the hip [J].
Ganz, R ;
Parvizi, J ;
Beck, M ;
Leunig, M ;
Nötzli, H ;
Siebenrock, KA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :112-120
[4]   Video task analysis of turning during activities of daily living [J].
Glaister, Brian C. ;
Bernatz, Greta C. ;
Klute, Glenn K. ;
Orendurff, Michael S. .
GAIT & POSTURE, 2007, 25 (02) :289-294
[5]   Three-Dimensional Knee Joint Kinematics during Golf Swing and Stationary Cycling after Total Knee Arthroplasty [J].
Hamai, Satoshi ;
Miura, Hiromasa ;
Higaki, Hidehiko ;
Shimoto, Takeshi ;
Matsuda, Shuichi ;
Okazaki, Ken ;
Iwamoto, Yukihide .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (12) :1556-1561
[6]   Kinematic analysis of kneeling in cruciate-retaining and posterior-stabilized total knee arthroplasties [J].
Hamai, Satoshi ;
Miura, Hiromasa ;
Higaki, Hidehiko ;
Matsuda, Shuichi ;
Shimoto, Takeshi ;
Sasaki, Kousuke ;
Yoshizumi, Masaaki ;
Okazaki, Ken ;
Tsukamoto, Nobuaki ;
Iwamoto, Yukihide .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (04) :435-442
[7]   In Vivo Healthy Knee Kinematics during Dynamic Full Flexion [J].
Hamai, Satoshi ;
Moro-oka, Taka-aki ;
Dunbar, Nicholas J. ;
Miura, Hiromasa ;
Iwamoto, Yukihide ;
Banks, Scott A. .
BIOMED RESEARCH INTERNATIONAL, 2013, 2013
[8]   Hip, knee, and ankle kinematics of high range of motion activities of daily living [J].
Hemmerich, A ;
Brown, H ;
Smith, S ;
Marthandam, SSK ;
Wyss, UP .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (04) :770-781
[9]   Three-Dimensional Motion Analysis of the Patellar Component in Total Knee Arthroplasty by the Image Matching Method Using Image Correlations [J].
Ishimaru, Masami ;
Shiraishi, Yoshitaka ;
Ikebe, Satoru ;
Higaki, Hidehiko ;
Hino, Kazunori ;
Onishi, Yoshio ;
Miura, Hiromasa .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (05) :619-626
[10]   In vivo fluoroscopic analysis of the normal human knee [J].
Komistek, RD ;
Dennis, DA ;
Mahfouz, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :69-81