Transretinal electrical stimulation by an intrascleral multichannel electrode array in rabbit eyes

被引:75
作者
Nakauchi, K
Fujikado, T
Kanda, H
Morimoto, T
Choi, JS
Ikuno, Y
Sakaguchi, H
Kamei, M
Ohji, M
Yagi, T
Nishimura, S
Sawai, H
Fukuda, Y
Tano, Y
机构
[1] Osaka Univ, Grad Sch Med, Dept Visual Sci, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Ophthalmol, Suita, Osaka 5650871, Japan
[3] Osaka Univ, Grad Sch Med, Dept Physiol, Suita, Osaka 5650871, Japan
[4] NIDEK Co, Gamagori, Japan
关键词
D O I
10.1007/s00417-004-1060-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: A new method of stimulating the retina electrically, called suprachoroidal transretinal stimulation (STS), was shown to be effective in eliciting electrically evoked cortical potentials (EEPs) in Royal College of Surgeons (RCS) rats. Before extending this technique to patients, it is important to determine its safety and feasibility in eliciting EEPs from medium-size animal (rabbits). The purpose of this study was to determine the safety and efficacy of the surgical procedures used to implant an multichannel electrode array into a scleral pocket, and to determine whether the implanted electrodes can stimulate the retina effectively. Methods: These acute experiments were conducted on six rabbits. An array of eight gold microelectrodes, embedded in polyimide, was implanted into a scleral pocket over the visual streak area. The size of the microarray was 2x4x0.180 mm. The reference electrode was implanted into the vitreous. The electrode array and reference electrodes were connected to a stimulator to deliver monophasic current pulses. Cortical responses were recorded with a stainless steel electrode implanted into each rabbit's skull over the visual cortex. After the experiment, the eyes and electrodes were examined histologically. Results: The surgical procedures for electrode implantation were accomplished without serious complications. EEPs were recorded after monophasic electrical pulse stimulation from each electrode. The mean threshold for EEPs was 55.0+/-10.0 muA with a 0.5-ms duration inward current pulse. The charge delivered at threshold was about 27.5 nC, and the charge density was about 56.0 muC/cm(2). Histopathological examination of the retinal tissue around the area of stimulation did not show damage at the light microscope level with the electrical parameters used. Conclusions: Our technique for STS with an intrascleral microelectrode array is safe in rabbit eyes, and EEPs were elicited by current densities that did not induce tissue damage. These results suggest that STS via intrascleral multichannel electrodes is a feasible method for stimulating the retina.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 18 条
  • [1] VISUAL-FIELD REPRESENTATION IN NEWBORN RABBITS CORTEX
    CHOUDHURY, BP
    [J]. BRAIN RESEARCH, 1978, 153 (01) : 27 - 37
  • [2] Subretinal electrical stimulation of the rabbit retina
    Chow, AY
    Chow, VY
    [J]. NEUROSCIENCE LETTERS, 1997, 225 (01) : 13 - 16
  • [3] Chow AY, 2002, J REHABIL RES DEV, V39, P313
  • [4] DAWSON WW, 1977, INVEST OPHTH VIS SCI, V16, P249
  • [5] Learning retina implants with epiretinal contacts
    Eckmiller, R
    [J]. OPHTHALMIC RESEARCH, 1997, 29 (05) : 281 - 289
  • [6] Humayun M S, 2001, Trans Am Ophthalmol Soc, V99, P271
  • [7] Visual perception elicited by electrical stimulation of retina in blind humans
    Humayun, MS
    deJuan, E
    Dagnelie, G
    Greenberg, RJ
    Prost, RH
    Phillips, DH
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (01) : 40 - 46
  • [8] INOUE J, 1971, NIPPON GANKA GAKKAI, V20, P765
  • [9] Electrophysiological studies of the feasibility of suprachoroidal-transretinal stimulation for artificial vision in normal and RCS rats
    Kanda, H
    Morimoto, T
    Fujikado, T
    Tano, Y
    Fukuda, Y
    Sawai, H
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (02) : 560 - 566
  • [10] Majji AB, 1999, INVEST OPHTH VIS SCI, V40, P2073