Object. The purpose of this study was to investigate whether thicker-core-diameter screws increase fixation strength in the cervical spine. Methods. Bone mineral density (BMD) was determined for each vertebral body (VB) obtained in six human C4-7 segments. Based on their BMD, the specimens were assigned to one of two groups in which torque and pullout force were tested. Two initial pilot holes were drilled into the VBs and tests were first performed using a standard screw. The test was repeated using a thicker rescue screw inserted into the same initial pilot hole. The mean value of peak torque and pullout force resulting from the single left/right measurements was used for statistical analysis. A t-test was performed to determine the effect of screw design on peak torque and pullout force. Moment correlation coefficients were calculated to determine the effect of BMD on peak torque and pullout force. Mean insertional peak torque for the standard screw was 82.1 N/cm and that for the rescue screw was 47.6 Ncm (p < 0.001). There was a strong correlation between insertional peak torque and BMD for both standard screws (r = 0.71, p = 0.02) and rescue screws (r = 0.59, p = 0.07). The mean pullout force for standard screws was 464.7 N, whereas it was 164.5 N for rescue screws (p < 0.001). There was a strong correlation between pullout force and BMD for both standard (r = 0.75, p = 0.0081) and rescue screws (r = 0.7, p = 0.025). Conclusions. Uncemented rescue screws that have been inserted into a fatigued hole in the cervical VB do not strengthen the screw-bone interface compared with the strength initially conferred by a standard screw.
机构:
Univ Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, BrazilUniv Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, Brazil
Defino, Helton L. A.
Rosa, Rodrigo Cesar
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, BrazilUniv Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, Brazil
Rosa, Rodrigo Cesar
Silva, Patricia
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, BrazilUniv Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, Brazil
Silva, Patricia
Shimano, Antonio Carlos
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, BrazilUniv Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, Brazil
Shimano, Antonio Carlos
Volpon, Jose Batista
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, BrazilUniv Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, Brazil
Volpon, Jose Batista
Albuquerque de Paula, Francisco Jose
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Dept Internal Med, Sao Paulo, BrazilUniv Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, Brazil
Albuquerque de Paula, Francisco Jose
Schleicher, Philipp
论文数: 0引用数: 0
h-index: 0
机构:
Charite Univ Med Berlin, Ctr Musculoskeletal Surg, Berlin, GermanyUniv Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, Brazil
Schleicher, Philipp
Schnake, Klaus
论文数: 0引用数: 0
h-index: 0
机构:
Charite Univ Med Berlin, Ctr Musculoskeletal Surg, Berlin, GermanyUniv Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, Brazil
Schnake, Klaus
Kandziora, Frank
论文数: 0引用数: 0
h-index: 0
机构:
Charite Univ Med Berlin, Ctr Musculoskeletal Surg, Berlin, GermanyUniv Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, Brazil