EFFECT OF MICROBUBBLE SIZE ON FUNDAMENTAL MODE HIGH FREQUENCY ULTRASOUND IMAGING IN MICE

被引:138
作者
Sirsi, Shashank [1 ]
Feshitan, Jameel [1 ]
Kwan, James [1 ]
Homma, Shunichi [2 ]
Borden, Mark [1 ]
机构
[1] Columbia Univ, Dept Chem Engn, New York, NY 10027 USA
[2] Columbia Univ, Med Ctr, Div Cardiol, New York, NY 10027 USA
关键词
Contrast agent; Diameter; Circulation persistence; Scattering cross-section; Absorption; Kidney; CONTRAST AGENTS; FILLED MICROBUBBLES; STANDARD PROPERTIES; TUMOR XENOGRAFTS; DRUG-DELIVERY; BUBBLE-SIZE; ATTENUATION; QUANTIFICATION; MICROSPHERES; INFLAMMATION;
D O I
10.1016/j.ultrasmedbio.2010.03.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
High-frequency ultrasound imaging using microbubble (MB) contrast agents is becoming increasingly popular in pre-clinical and small animal studies of anatomy, flow and vascular expression of molecular epitopes. Currently, in vivo imaging studies rely on highly polydisperse microbubble suspensions, which may provide a complex and varied acoustic response. To study the effect of individual microbubble size populations, microbubbles of 1-2 mu m, 4-5 mu m and 6-8 mu m diameter were isolated using the technique of differential centrifugation. Size-selected microbubbles were imaged in the mouse kidney over a range of concentrations using a Visualsonics Vevo 770 ultrasound imaging system (Visualsonics, Toronto, Ontario, Canada) with a 40-MHz probe in fundamental mode. Results demonstrate that contrast enhancement and circulation persistence are strongly dependent on microbubble size and concentration. Large microbubbles (4-5 and 6-8 mu m) strongly enhanced the ultrasound image with positive contrast, while 1-2 ?m microbubbles showed little enhancement. For example, the total integrated contrast enhancement, measured by the area under the time-intensity curve (AUC), increased 16-fold for 6-8 mu m diameter microbubbles at 5 x 10(7) MB/bolus compared with 4-5 mu m microbubbles at the same concentration. Interestingly, 1-2 mu m diameter microbubbles, at any concentration, did not measurably enhance the integrated ultrasound signal at tissue depth, but did noticeably attenuate the signal, indicating that they had a low scattering-to-attenuation ratio. When concentration matched, larger microbubbles were more persistent in circulation. However, when volume matched, all microbubble sizes had a similar circulation half-life. These results indicated that dissolution of the gas core plays a larger role in contrast elimination than filtering by the lungs and spleen. The results of this study show that microbubbles can be tailored for optimal contrast enhancement in fundamental mode imaging. (E-mail: mb2910@columbia.edu) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:935 / 948
页数:14
相关论文
共 47 条
  • [1] Oxygen permeability of fully condensed lipid monolayers
    Borden, MA
    Longo, ML
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2004, 108 (19) : 6009 - 6016
  • [2] Dissolution behavior of lipid monolayer-coated, air-filled microbubbles: Effect of lipid hydrophobic chain length
    Borden, MA
    Longo, ML
    [J]. LANGMUIR, 2002, 18 (24) : 9225 - 9233
  • [3] Standard properties of ultrasound contrast agents
    Bouakaz, A
    De Jong, N
    Cachard, C
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (03) : 469 - 472
  • [4] On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent
    Bouakaz, A
    de Jong, N
    Cachard, C
    Jouini, K
    [J]. ULTRASONICS, 1998, 36 (1-5) : 703 - 708
  • [5] CHAN M, 1997, JPN J APPL PHYS, V36, P3
  • [6] Ultrasound attenuation in encapsulated microbubble suspensions: The multiple scattering effects
    Chen, Jiusheng
    Zhu, Zhemin
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (06) : 961 - 969
  • [7] Coatney R W, 2001, ILAR J, V42, P233
  • [8] Targeted imaging using ultrasound
    Dayton, PA
    Ferrara, KW
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (04) : 362 - 377
  • [9] ULTRASOUND SCATTERING PROPERTIES OF ALBUNEX MICROSPHERES
    DEJONG, N
    HOFF, L
    [J]. ULTRASONICS, 1993, 31 (03) : 175 - 181
  • [10] ABSORPTION AND SCATTER OF ENCAPSULATED GAS FILLED MICROSPHERES - THEORETICAL CONSIDERATIONS AND SOME MEASUREMENTS
    DEJONG, N
    HOFF, L
    SKOTLAND, T
    BOM, N
    [J]. ULTRASONICS, 1992, 30 (02) : 95 - 103