Real-time immunoassay of ferritin using surface plasmon resonance biosensor

被引:47
作者
Cui, XQ [1 ]
Yang, F [1 ]
Sha, YF [1 ]
Yang, XR [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
surface plasmon resonance; immunoassay; ferritin; sandwich enhancement;
D O I
10.1016/S0039-9140(03)00043-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A surface plasmon resonance (SPR) biosensor was used for the first time to determine the concentration of ferritin in both HBS-EP buffer and serum. The monoclonal antibody was immobilized on the carboxymethyl dextran-modified gold surface by an amine coupling method. The interaction of antibody with antigen was monitored in real-time. The signal was enhanced by sandwich amplification strategy to improve the sensitivity and specificity of the immunoassay, especially in serum. The linear range of the assay in serum is over 30-200 ng ml with the detection limit of 28 ng ml(-1). The sensitivity, specificity, and reproducibility of the assay are satisfactory. The analyte and enhancement antibody-binding surface could be regenerated by pH 2.0 glycine-HCl buffer and the same antibody-immobilized surface could be used for more than 50 cycles of ferritin binding and regeneration. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 50 条
  • [21] Real-time monitoring of odorant-induced cellular reactions using surface plasmon resonance
    Lee, Sang Hun
    Ko, Hwi Jin
    Park, Tai Hyun
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (01) : 55 - 60
  • [22] Immunoassay for the determination of morphine-3-glucuronide using a surface plasmon resonance-based biosensor
    Dillon, PP
    Daly, SJ
    Manning, BM
    O'Kennedy, R
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) : 217 - 227
  • [23] Real-time monitoring of lead ion interaction on gold/chitosan surface using surface plasmon resonance spectroscopy
    Fen, Y. W.
    Yunus, W. M. M.
    Talib, Z. A.
    INDIAN JOURNAL OF PHYSICS, 2012, 86 (07) : 619 - 623
  • [24] Real-time monitoring of lead ion interaction on gold/chitosan surface using surface plasmon resonance spectroscopy
    Y. W. Fen
    W. M. M. Yunus
    Z. A. Talib
    Indian Journal of Physics, 2012, 86 : 619 - 623
  • [25] Surface plasmon resonance biosensor using heterodyne interferometry
    Joe, SF
    Wu, CM
    Chang, LB
    Hsieh, LZ
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS II PT 1AND 2, 2004, 5634 : 166 - 173
  • [26] Real-time Detection of Single Immobilized Nanoparticles by Surface Plasmon Resonance Imaging
    Alexander Zybin
    Yurii A. Kuritsyn
    Evgeny L. Gurevich
    Vladimir V. Temchura
    Klaus Überla
    Kay Niemax
    Plasmonics, 2010, 5 : 31 - 35
  • [27] Real-time Detection of Single Immobilized Nanoparticles by Surface Plasmon Resonance Imaging
    Zybin, Alexander
    Kuritsyn, Yurii A.
    Gurevich, Evgeny L.
    Temchura, Vladimir V.
    Ueberla, Klaus
    Niemax, Kay
    PLASMONICS, 2010, 5 (01) : 31 - 35
  • [28] Immunoassay for the determination of 7-hydroxycoumarin in serum using 'real-time' biosensor analysis
    Keating, GJ
    Quinn, JG
    O'Kennedy, R
    ANALYTICAL LETTERS, 1999, 32 (11) : 2163 - 2176
  • [29] Real-time analysis of antibody interactions with whole enveloped human cytomegalovirus using surface plasmon resonance
    Chenail, Gregg
    Brown, Nathan E.
    Shea, Ashley
    Feire, Adam L.
    Deng, Gejing
    ANALYTICAL BIOCHEMISTRY, 2011, 411 (01) : 58 - 63
  • [30] Real-time composition and deposition depth profile of metal alloys using electrochemical surface plasmon resonance
    Bin, Yannan
    Fu, Qingli
    Hou, Yuting
    Xiang, Juan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 699 : 10 - 13