Ultrasensitive label-free electrochemical immunosensor based on PVA-co-PE nanofibrous membrane for the detection of chloramphenicol residues in milk

被引:70
作者
El-Moghazy, Ahmed Y. [1 ,2 ]
Zhao, Cunyi [1 ]
Istamboulie, Georges [3 ,4 ,5 ]
Amaly, Noha [1 ,2 ]
Si, Yang [1 ]
Noguer, Thierry [3 ,4 ,5 ]
Sun, Gang [1 ]
机构
[1] Univ Calif Davis, Fiber & Polymer Sci, Davis, CA 95616 USA
[2] City Sci Res & Technol Applicat SRTA City, Adv Technol & New Mat Res Inst, Polymer Mat Res Dept, Alexandria 21934, Egypt
[3] Univ Perpignan, Biocapteurs Anal Environm, Via Domitia, Perpignan, France
[4] Sorbonne Univ UPMC Paris 6, Lab Biodivers & Biotechnol Microbiennes, USR 3579, F-66650 Banyuls Sur Mer, France
[5] CNRS, Observ Oceanol, F-66650 Banyuls Sur Mer, France
关键词
Electrochemical immunosensor; Label-free; PVA-co-PE; Nanofibers; Chloramphenicol; Milk; GENETICALLY-ENGINEERED ACETYLCHOLINESTERASE; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; VOLTAMMETRIC DETERMINATION; AMPEROMETRIC IMMUNOSENSOR; CARBON NANOTUBES; OLIVE OIL; BIOSENSOR; NANOPARTICLES; IMMUNOASSAY;
D O I
10.1016/j.bios.2018.07.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An ultrasensitive label-free amperometric immunosensor for the detection of chloramphenicol (CAP) residues in milk has been developed by using a screen-printed carbon electrode laminated with a layer of poly (vinyl alcohol -co-ethylene) (PVA-co-PE) nanofibrous membrane that is covalently immobilized with a CAP antibody (anti-CAP). The performance of the PVA-co-PE nanofiber membrane (PVA-co-PE NFM) on the electrode was compared with a PVA-co-PE casted membrane (PVA-co-PE CM), necessary fabrication steps and performance of the sensors were investigated by electrochemical impedance spectroscopy (EIS). The application of the PVA-co-PE NFM decreased the electron-transfer-resistance by about 4 times compared with a conventional PVA-co-PE casted membrane. Under the optimal conditions, the established immunosensor exhibited high sensitivity for determination of CAP in a range 0.01-10 ng in L-1, with a limit of detection of 0.0047 ng mL(-1). In addition to the good selectivity, reusability and stability over time, the prepared immunosensor was successfully used in the detection of CAP in milk samples without any pretreatment.
引用
收藏
页码:838 / 844
页数:7
相关论文
共 54 条
[1]   Reusable anionic sulfonate functionalized nanofibrous membranes for cellulase enzyme adsorption and separation [J].
Amaly, Noha ;
Si, Yang ;
Chen, Yike ;
El-Moghazy, Ahmed Y. ;
Zhao, Cunyi ;
Zhang, Ruihong ;
Sun, Gang .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2018, 170 :588-595
[2]  
[Anonymous], 2017, SENSORS
[3]   Development and validation of screening and confirmatory methods for the detection of chloramphenicol and chloramphenicol glucuronide using SPR biosensor and liquid chromatography-tandem mass spectrometry [J].
Ashwin, HM ;
Stead, SL ;
Taylor, JC ;
Startin, JR ;
Richmond, SF ;
Homer, V ;
Bigwood, T ;
Sharman, M .
ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) :103-108
[4]   Synthesis of nitrogen-doped graphene nanosheets decorated with gold nanoparticles as an improved sensor for electrochemical determination of chloramphenicol [J].
Borowiec, Joanna ;
Wang, Rui ;
Zhu, Lihua ;
Zhang, Jingdong .
ELECTROCHIMICA ACTA, 2013, 99 :138-144
[5]   Capacity Fade Mechanism of Li4Ti5O12 Nanosheet Anode [J].
Chiu, Hsien-Chieh ;
Lu, Xia ;
Zhou, Jigang ;
Gu, Lin ;
Reid, Joel ;
Gauvin, Raynald ;
Zaghib, Karim ;
Demopoulos, George P. .
ADVANCED ENERGY MATERIALS, 2017, 7 (05)
[6]   Liquid chromatographic-mass spectrometric methods for analyzing antibiotic and antibacterial agents in animal food products [J].
Di Corcia, A ;
Nazzari, M .
JOURNAL OF CHROMATOGRAPHY A, 2002, 974 (1-2) :53-89
[7]   Development of an Immunoassay for Chloramphenicol Based on the Preparation of a Specific Single-Chain Variable Fragment Antibody [J].
Du, Xin-jun ;
Zhou, Xiao-nan ;
Li, Ping ;
Sheng, Wei ;
Ducancel, Frederic ;
Wang, Shuo .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (14) :2971-2979
[8]   Alternating current (AC) impedance imaging with combined atomic force scanning electrochemical microscopy (AFM-SECM) [J].
Eckhard, K. ;
Shin, H. ;
Mizaikoff, B. ;
Schuhmann, W. ;
Kranz, C. .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (06) :1311-1315
[9]   Biosensor based on electrospun blended chitosan-poly (vinyl alcohol) nanofibrous enzymatically sensitized membranes for pirimiphosmethyl detection in olive oil [J].
El-Moghazy, A. Y. ;
Soliman, E. A. ;
Ibrahim, H. Z. ;
Marty, J. -L. ;
Istamboulie, G. ;
Noguer, T. .
TALANTA, 2016, 155 :258-264
[10]   Ultra-sensitive biosensor based on genetically engineered acetylcholinesterase immobilized in poly (vinyl alcohol)/Fe-Ni alloy nanocomposite for phosmet detection in olive oil [J].
El-Moghazy, A. Y. ;
Soliman, E. A. ;
Ibrahim, H. Z. ;
Noguer, T. ;
Marty, J. -L. ;
Istamboulie, G. .
FOOD CHEMISTRY, 2016, 203 :73-78