An LC-MS/MS method for creatine and creatinine analysis in paraquat-intoxicated patients

被引:6
作者
Sukhang, Mukdawan [1 ]
Junkuy, Anongphan [1 ]
Buckley, Nicholas [2 ,3 ]
Mohamed, Fahim [2 ,3 ,4 ]
Wunnapuk, Klintean [1 ]
机构
[1] Chiang Mai Univ, Fac Med, Dept Forens Med, Toxicol Unit, Chiang Mai 50200, Thailand
[2] Univ Peradeniya, South Asian Clin Toxicol Res Collaborat, Peradeniya, Sri Lanka
[3] Univ Sydney, Fac Med & Hlth, Discipline Pharmacol, Clin Pharmacol & Toxicol Res Grp, Sydney, NSW, Australia
[4] Univ Peradeniya, Fac Allied Hlth Sci, Peradeniya, Sri Lanka
基金
澳大利亚国家健康与医学研究理事会;
关键词
Liquid chromatography tandem mass spectrometry; creatine; creatinine; paraquat; poisoning; method validation; method comparison; matrix effect; acute kidney injury; kidney function; nephrotoxicity; TANDEM MASS-SPECTROMETRY; SERUM CREATININE; KIDNEY INJURY; PLASMA; URINE; KINETICS; HPLC; GUANIDINOACETATE; VALIDATION; ACID;
D O I
10.1080/03601234.2019.1690342
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A sudden increase in serum creatinine after paraquat intoxication has been reported in several clinical studies. However, this dramatic change of creatinine may be possibly due to an interconversion of creatine-creatinine in relation to paraquat toxicity. In order to investigate the creatine-creatinine relationship, a liquid chromatography tandem mass spectrometry in combination with electrospray ionization was developed and validated for simultaneous determination of creatine and creatinine in the serum. The chromatographic separation was achieved on a Gemini (R) C-6-Phenyl column with a gradient elution consisting of 0.1% formic acid in ultrapure water and methanol as the mobile phase. The method yielded suitable levels of specificity and selectivity, and calibration curves of creatine and creatinine in serum were linear over the concentration range of 0.5-200 mu g mL(-1). The limit of quantification of both compounds was 0.5 mu g mL(-1), and the method was accurate within the recovery range of 96.23-102.75%, indicating the robustness of the method. The method was successfully applied to toxicological samples from paraquat-intoxicated patients, and the concentrations of creatine and creatinine were quantified. High creatine concentrations in serum samples were observed which may lead to high serum creatinine despite normal kidney function as creatine is converted to creatinine in proportion to its concentration.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 43 条
  • [1] HIGH SERUM CONCENTRATIONS OF PARAQUAT INCREASE APPARENT CREATININE CONCENTRATIONS
    AITKEN, RG
    NORTHALL, H
    YORK, GA
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1994, 31 : 198 - 199
  • [3] [Anonymous], 2001, GUID IND BIOAN METH
  • [4] [Anonymous], 1996, Guidance for industry: Q2b validation of analytical procedures: Methodology
  • [5] [Anonymous], 2011, Science Medicines Health, Guideline on bioanalytical method validation.
  • [6] A comparison of observed versus estimated baseline creatinine for determination of RIFLE class in patients with acute kidney injury
    Bagshaw, Sean M.
    Uchino, Shigehiko
    Cruz, Dinna
    Bellomo, Rinaldo
    Morimatsu, Hiroshi
    Morgera, Stanislao
    Schetz, Miet
    Tan, Ian
    Bouman, Catherine
    Macedo, Etienne
    Gibney, Noel
    Tolwani, Ashita
    Oudemans-van Straaten, Heleen M.
    Ronco, Claudio
    Kellum, John A.
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2009, 24 (09) : 2739 - 2744
  • [7] PARAQUAT POISONING - PROLONGED EXCRETION
    BEEBEEJAUN, AR
    BEEVERS, G
    ROGERS, WN
    [J]. CLINICAL TOXICOLOGY, 1971, 4 (03) : 397 - +
  • [8] Predictive performance of renal function equations for patients with chronic kidney disease and normal serum creatinine levels
    Bostom, AG
    Kronenberg, F
    Ritz, E
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 (08): : 2140 - 2144
  • [9] Simultaneous determination of guanidinoacetate, creatine and creatinine in urine and plasma by un-derivatized liquid chromatography-tandem mass spectrometry
    Carling, R. S.
    Hogg, S. L.
    Wood, T. C.
    Calvin, J.
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 : 575 - 584
  • [10] Determination of guanidinoacetate and creatine in urine and plasma by liquid chromatography-tandem mass spectrometry
    Cognat, SB
    Cheillan, D
    Piraud, M
    Roos, B
    Jakobs, C
    Viany-Saban, C
    [J]. CLINICAL CHEMISTRY, 2004, 50 (08) : 1459 - 1461