Evaluation of canine red blood cell quality after processing with an automated cell salvage device

被引:8
作者
Hofbauer, Nina [1 ]
Windberger, Ursula [4 ]
Schwendenwein, Ilse [2 ]
Tichy, Alexander [3 ]
Eberspaecher, Eva [1 ]
机构
[1] Univ Vet Med, Dept Anesthesiol & Perioperat Intens Care, A-1210 Vienna, Austria
[2] Univ Vet Med, Dept Pathobiol, Cent Lab, A-1210 Vienna, Austria
[3] Univ Vet Med, Dept Biomed Sci, A-1210 Vienna, Austria
[4] Med Univ Vienna, Decentralized Biomed Facil, Vienna, Austria
关键词
autologous transfusion; autotransfusion; dog; hemoabdomen; packed RBC; erythrocytes; MULTIPLE ORGAN FAILURE; MYELOPEROXIDASE DEFICIENCY; NORMAL SALINE; BANKED BLOOD; TRANSFUSION; DOGS; AUTOTRANSFUSION; AGGREGATION; FLOW; DEFORMABILITY;
D O I
10.1111/vec.12472
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo evaluate the properties of RBC concentrate harvested after processing fresh whole blood units from healthy dogs with an automated cell salvage device. DesignProspective, in vitro, experimental study. SettingUniversity teaching hospital. AnimalsSixteen healthy, privately owned dogs of various breeds. InterventionsFresh canine whole blood collected in bags with citrate phosphate dextrose adenine solution was processed with an automated cell salvage device and analyzed in vitro. Laboratory values determined before (baseline, from a catheter sample) and after processing RBCs (procRBCs) included a complete blood count, selected blood chemistry analytes, erythrocyte osmotic resistance, whole blood viscosity, RBC aggregation, and RBC deformability. Measurements and Main ResultsTotal recovery of RBCs was 80% 12%. Hematocrit of the procRBCs yielded by the device was 77% +/- 3.7% (mean +/- standard deviation). Gross morphology of the RBCs remained unchanged. The mean corpuscular volume, erythrocyte osmotic resistance, RBC deformability, RBC aggregation, and the activity of lactate dehydrogenase showed minor but statistically significant changes from baseline. No differences in the concentrations of free hemoglobin were observed. Whole blood viscosity was less in the procRBCs. Seventy-seven percent (mean) of the platelets were washed out, while a mean of 57% of the leukocytes remained in the procRBCs. ConclusionsAlthough processing canine blood with this automated cell salvage device leads to slight changes in some properties of RBCs, most of these changes are comparable to changes seen in human blood after processing. Present data indicate that the use of this cell salvage device does not induce changes in canine RBC concentrate that would preclude its use for transfusion.
引用
收藏
页码:373 / 383
页数:11
相关论文
共 48 条
[21]  
Jain NC, 1986, SCHALMS VET HEMATOLO, P69
[22]   Effect of Blood Products Transfusion on the Development of Postinjury Multiple Organ Failure [J].
Johnson, Jeffrey L. ;
Moore, Ernest E. ;
Kashuk, Jeffry L. ;
Banerjee, Anirban ;
Cothren, C. Clay ;
Biffl, Walter L. ;
Sauaia, Angela .
ARCHIVES OF SURGERY, 2010, 145 (10) :973-977
[23]   Autologous canine red blood cell transfusion using cell salvage devices [J].
Kellett-Gregory, Lindsay M. ;
Seth, Mayank ;
Adamantos, Sophie ;
Chan, Daniel L. .
JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2013, 23 (01) :82-86
[24]  
Kirkpatrick UJ, 1998, BRIT J HAEMATOL, V101, P364
[25]  
Klenner S, 2010, TIERAERZTL PRAX K H, V38, P139
[26]   Clinical manifestation of myeloperoxidase deficiency [J].
Lanza, F .
JOURNAL OF MOLECULAR MEDICINE-JMM, 1998, 76 (10) :676-681
[27]   Effect of Leukoreduction on Transfusion-Induced Inflammation in Dogs [J].
McMichael, M. A. ;
Smith, S. A. ;
Galligan, A. ;
Swanson, K. S. ;
Fan, T. M. .
JOURNAL OF VETERINARY INTERNAL MEDICINE, 2010, 24 (05) :1131-1137
[28]   AUTOTRANSFUSION - QUALITY OF BLOOD PREPARED WITH A RED-CELL PROCESSING DEVICE [J].
MCSHANE, AJ ;
POWER, C ;
JACKSON, JF ;
MURPHY, DF ;
MACDONALD, A ;
MORIARTY, DC ;
OTRIDGE, BW .
BRITISH JOURNAL OF ANAESTHESIA, 1987, 59 (08) :1035-1039
[29]  
Mezger T. G., 2006, RHEOLOGY HDB USERS R, P33
[30]  
Milnor WR, 1989, HEMODYNAMICS, P55