Flexible operation of CSIRO's post-combustion CO2 capture pilot plantat the AGL Loy Yang power station

被引:43
|
作者
Bui, Mai [1 ]
Gunawan, Indra [2 ]
Verheyen, Vincent [3 ]
Feron, Paul [4 ]
Meuleman, Erik [5 ]
机构
[1] Monash Univ, Fac Sci, Sch Appl Sci & Engn, Clayton, Vic 3800, Australia
[2] Univ Adelaide, Entrepreneurship Commercialisat & Innovat Ctr, Adelaide, SA 5005, Australia
[3] Federat Univ Australia, Sch Appl & Biomed Sci, Churchill, Vic 3842, Australia
[4] CSIRO Energy Flagship Newcastle, Mayfield West, NSW 2304, Australia
[5] CSIRO Energy Flagship Melbourne, Clayton, Vic 3168, Australia
关键词
Post-combustion CO2 capture; Flexible operation; Pilot plant; Transient; Dynamic modelling; MODEL-PREDICTIVE CONTROL; MEA ABSORPTION PROCESSES; SOLVENT REGENERATION; CONTROL STRATEGIES; PLANTWIDE CONTROL; OPTIMIZATION; DEGRADATION; ELECTRICITY; SIMULATION; DESIGN;
D O I
10.1016/j.ijggc.2015.12.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Flexible operation has the potential to significantly improve the economic viability of post-combustion CO2 capture (PCC). However, the impact of disturbances from flexible operation of the PCC process is unclear. The purpose of this study was to investigate the effects of flexible operation in a PCC pilot plant by implementing step-changes for improved dynamic data reliability. The flexible operation campaign was conducted at the CSIRO PCC pilot plant at AGL Loy Yang using monoethanolamine (MEA) absorbent. The pilot plant was operated under a broad range of transient conditions (changing flue gas flow, liquid absorbent flow and steam pressure) to capture the dynamics of a PCC process during flexible operation. The study demonstrated that the dynamics of flue gas flow rate was faster than absorbent flow rate. The greatest CO2 removal% was achieved at the lowest flue gas flow rate or at the highest absorbent flow rate; however, the latter provided improved energy efficiency. The steam pressure parameter could adjust the temperature of all columns simultaneously which can be used to compensate for effects from ambient conditions or heat losses. These results verify the technical feasibility of flexible PCC operation and provide a suitable dataset for dynamic model validation. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:188 / 203
页数:16
相关论文
共 50 条
  • [31] Flexible operation of Post-combustion CO2 capture process enabled by NARX-MPC using neural network
    Jung, Howoun
    Lee, Jay H.
    COMPUTERS & CHEMICAL ENGINEERING, 2023, 179
  • [32] Dynamic modelling and control strategies for flexible operation of amine-based post-combustion CO2 capture systems
    Minh Tri Luu
    Manaf, Norhuda Abdul
    Abbas, Ali
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2015, 39 : 377 - 389
  • [33] Flexible operation of coal-fired power plant integrated with post combustion CO2 capture
    Liao, Peizhi
    Wu, Xiao
    Li, Yiguo
    Wang, Meihong
    Shen, Jiong
    Sun, Bo
    Pan, Lei
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 4810 - 4815
  • [34] Thermal degradation of morpholine in CO2 post-combustion capture
    Ogidi, Michael O.
    Thompson, Warren A.
    Maroto-Valer, M. Mercedes
    13TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-13, 2017, 114 : 1033 - 1037
  • [35] Highly efficient absorbents for post-combustion CO2 capture
    Shim, Jae-Goo
    Kim, Jun-Han
    Lee, Ji Hyun
    Jang, Kyung-Ryong
    GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01): : 779 - 782
  • [36] New solvent blends for post-combustion CO2 capture
    Hanna K.Knuutila
    Rune Rennemo
    Arlinda F.Ciftja
    GreenEnergy&Environment, 2019, 4 (04) : 439 - 452
  • [37] Advancement in porous adsorbents for post-combustion CO2 capture
    Modak, Arindam
    Jana, Subhra
    MICROPOROUS AND MESOPOROUS MATERIALS, 2019, 276 : 107 - 132
  • [38] Analysis and status of post-combustion CO2 capture technologies
    Bhown, Abhoyjit S.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [39] Cascaded Membrane Processes for Post-Combustion CO2 Capture
    Zhao, Li
    Riensche, Ernst
    Weber, Michael
    Stolten, Detlef
    CHEMICAL ENGINEERING & TECHNOLOGY, 2012, 35 (03) : 489 - 496
  • [40] SOLID SORBENT POST-COMBUSTION CO2 CAPTURE IN SUBCRITICAL PC POWER PLANT
    Chen, Qin
    Rao, Ashok
    Samuelsen, Scott
    PROCEEDINGS OF THE ASME 9TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2015, VOL 1, 2016,