Flexible operation of CSIRO's post-combustion CO2 capture pilot plantat the AGL Loy Yang power station

被引:44
作者
Bui, Mai [1 ]
Gunawan, Indra [2 ]
Verheyen, Vincent [3 ]
Feron, Paul [4 ]
Meuleman, Erik [5 ]
机构
[1] Monash Univ, Fac Sci, Sch Appl Sci & Engn, Clayton, Vic 3800, Australia
[2] Univ Adelaide, Entrepreneurship Commercialisat & Innovat Ctr, Adelaide, SA 5005, Australia
[3] Federat Univ Australia, Sch Appl & Biomed Sci, Churchill, Vic 3842, Australia
[4] CSIRO Energy Flagship Newcastle, Mayfield West, NSW 2304, Australia
[5] CSIRO Energy Flagship Melbourne, Clayton, Vic 3168, Australia
关键词
Post-combustion CO2 capture; Flexible operation; Pilot plant; Transient; Dynamic modelling; MODEL-PREDICTIVE CONTROL; MEA ABSORPTION PROCESSES; SOLVENT REGENERATION; CONTROL STRATEGIES; PLANTWIDE CONTROL; OPTIMIZATION; DEGRADATION; ELECTRICITY; SIMULATION; DESIGN;
D O I
10.1016/j.ijggc.2015.12.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Flexible operation has the potential to significantly improve the economic viability of post-combustion CO2 capture (PCC). However, the impact of disturbances from flexible operation of the PCC process is unclear. The purpose of this study was to investigate the effects of flexible operation in a PCC pilot plant by implementing step-changes for improved dynamic data reliability. The flexible operation campaign was conducted at the CSIRO PCC pilot plant at AGL Loy Yang using monoethanolamine (MEA) absorbent. The pilot plant was operated under a broad range of transient conditions (changing flue gas flow, liquid absorbent flow and steam pressure) to capture the dynamics of a PCC process during flexible operation. The study demonstrated that the dynamics of flue gas flow rate was faster than absorbent flow rate. The greatest CO2 removal% was achieved at the lowest flue gas flow rate or at the highest absorbent flow rate; however, the latter provided improved energy efficiency. The steam pressure parameter could adjust the temperature of all columns simultaneously which can be used to compensate for effects from ambient conditions or heat losses. These results verify the technical feasibility of flexible PCC operation and provide a suitable dataset for dynamic model validation. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:188 / 203
页数:16
相关论文
共 60 条
  • [51] UT/SRP CO2 Capture Pilot Plant - Operating Experience and Procedures
    Seibert, F.
    Chen, E.
    Perry, M.
    Briggs, S.
    Montgomery, R.
    Rochelle, G.
    [J]. 10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 1616 - 1623
  • [52] Catalysts and inhibitors for oxidative degradation of monoethanolamine
    Sexton, Andrew J.
    Rochelle, Gary T.
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2009, 3 (06) : 704 - 711
  • [53] Rate based modeling and validation of a carbon-dioxide pilot plant absorbtion column operating on monoethanolamine
    Simon, Levente L.
    Elias, Yannick
    Puxty, Graeme
    Artanto, Yuli
    Hungerbuhler, Konrad
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (09) : 1684 - 1692
  • [54] Smith C.L., 2002, CHEM ENG
  • [55] Start-Up of World's First Commercial Post-Combustion Coal Fired CCS Project: Contribution of Shell Cansolv to SaskPower Boundary Dam ICCS Project
    Stephenne, Karl
    [J]. 12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 : 6106 - 6110
  • [56] Inline Monitoring of CO2 Absorption Processes Using Simple Analytical Techniques and Multivariate Modeling
    van der Ham, Leen V.
    Bakker, Daphne E.
    Geers, Leon F. G.
    Goetheer, Earl L. V.
    [J]. CHEMICAL ENGINEERING & TECHNOLOGY, 2014, 37 (02) : 221 - 228
  • [57] Benefits of coal-fired power generation with flexible CCS in a future northwest European power system with large scale wind power
    van der Wijk, Pieter Cornelis
    Brouwer, Anne Sjoerd
    van den Broek, Machteld
    Slot, Thijs
    Stienstra, Gerard
    van der Veen, Wim
    Faaij, Andre P. C.
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2014, 28 : 216 - 233
  • [58] Online Monitoring of the Solvent and Absorbed Acid Gas Concentration in a CO2 Capture Process Using Monoethanolamine
    van Eckeveld, Andries C.
    van der Ham, Leen V.
    Geers, Leon F. G.
    van den Broeke, Leo J. P.
    Boersma, Bendiks J.
    Goetheer, Earl L. V.
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (13) : 5515 - 5523
  • [59] Investigating flexible carbon capture opportunities in the Australian electricity market
    Zhang, Yuanfei
    Ho, Minh T.
    Wiley, Dianne E.
    [J]. GHGT-11, 2013, 37 : 2746 - 2753
  • [60] Optimum Design and Control of Amine Scrubbing in Response to Electricity and CO2 prices
    Ziaii, Sepideh
    Rochelle, Gary T.
    Edgar, Thomas F.
    [J]. 10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 1683 - 1690