Interleukin-10 appearance following thoraco-abdominal and abdominal aortic aneurysm repair is associated with the duration of visceral ischaemia

被引:16
|
作者
Oldenburg, HSA [1 ]
Welborn, MB [1 ]
Pruitt, JH [1 ]
Boelens, PG [1 ]
Seeger, JM [1 ]
Martin, TD [1 ]
Wesdorp, RIC [1 ]
Rauwerda, JA [1 ]
van Leeuwen, PAM [1 ]
Moldawer, LL [1 ]
机构
[1] Vrije Univ Hosp, Dept Surg, NL-1081 HV Amsterdam, Netherlands
关键词
IL-10; visceral ischaemia; aortic aneurysm;
D O I
10.1053/ejvs.2000.1147
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: to evaluate the plasma IL-10 levels during elective operative repair of thoraco-abdominal and abdominal aortic aneurysm repair. To study whether IL-10 plasma levels ae associated wit the duration of cross-clamping (ischaemia) and clinical outcome. Materials: fifteen consecutive patients undergoing surgery for TAAA and 10 consecutive patients undergoing surgical repair of AAA were included. Methods: plasma concentrations of IL-10 were measured by ELISA technique. Clinical outcome of the TAAA patients was prospectively analysed. Results: during aortic clamping IL-10 was produced in both populations. The plasm IL-10 peak (934 +/- 172 pg/ml) of the TAAA group was seen at 4 h after declamping and remained detectable after 48 h. The plasma IL-10 peak (212 +/- 32 pg/ml) of the AAA group was seen 30 min after declamping and fell to undetectable levels by 24 h. These data show that the peak IL-10 plasma levels in TAAA repair are significantly (p < 0.05) higher compared to the peak IL-10 plasma levels as seen during AAA repair. A positive correlation was seen between cross-clamping and peak plasma IL-10 and organ dysfunction. Conclusions: IL-10 plasma concentrations appear higher, later and are longer detectable in patients undergoing TAAA. Correlations were seen with duration of cross-clamping and MSOD.
引用
收藏
页码:169 / 172
页数:4
相关论文
共 50 条
  • [41] The use of direct thrombin injection to treat a type II endoleak following endovascular repair of abdominal aortic aneurysm
    Ellis, PK
    Kennedy, PT
    Collins, AJ
    Blair, PH
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 26 (05) : 482 - 484
  • [42] Survival Disparity Following Abdominal Aortic Aneurysm Repair Highlights Inequality in Ethnic and Socio-economic Status
    Khashram, Manar
    Pitama, Suzanne
    Williman, Jonathan A.
    Jones, Gregory T.
    Roake, Justin A.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2017, 54 (06) : 689 - 696
  • [43] The Use of Direct Thrombin Injection to Treat a Type II Endoleak Following Endovascular Repair of Abdominal Aortic Aneurysm
    Peter K. Ellis
    Peter T. Kennedy
    Anton J. Collins
    Paul H. Blair
    CardioVascular and Interventional Radiology, 2003, 26 (5) : 482 - 484
  • [44] Outcomes of off-the-shelf preloaded inner branch device for urgent endovascular thoraco-abdominal aortic repair in the ItaliaN Branched Registry of E-nside EnDograft
    Piazza, Michele
    Squizzato, Francesco
    Ferri, Michelangelo
    Pratesi, Giovanni
    Gatta, Emanuele
    Orrico, Matteo
    Giudice, Rocco
    Antonello, Michele
    JOURNAL OF VASCULAR SURGERY, 2024, 80 (05)
  • [45] Changes in platelet count, coagulation and fibrinogen associated with elective repair of asymptomatic abdominal aortic aneurysm and aortic reconstruction for occlusive disease
    Bradbury, A
    Adam, D
    Garrioch, M
    Brittenden, J
    Gillies, T
    Ruckley, CV
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 13 (04) : 375 - 380
  • [46] Transabdominal open abdominal aortic aneurysm repair is associated with higher rates of late reintervention and readmission compared with the retroperitoneal approach
    Deery, Sarah E.
    Zettervall, Sara L.
    O'Donnell, Thomas F. X.
    Goodney, Philip P.
    Weaver, Fred A.
    Teixeira, Pedro G.
    Patel, Virendra I.
    Schermerhorn, Marc L.
    JOURNAL OF VASCULAR SURGERY, 2020, 71 (01) : 39 - +
  • [47] Filling of the aneurysmal sac with DEAC-glucosamine in an animal model of abdominal aortic aneurysm following stent-graft repair
    Uflacker, R.
    Brothers, T.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2006, 47 (04) : 425 - 436
  • [48] Early inflammatory response following elective abdominal aortic aneurysm repair: a comparison between endovascular procedure and conventional, open surgery
    Marjanovic, Ivan
    Jevtic, Miodrag
    Misovic, Sidor
    Vojvodic, Danilo
    Zoranovic, Uros
    Rusovic, Sinisa
    Sarac, Momir
    Stanojevic, Ivan
    VOJNOSANITETSKI PREGLED, 2011, 68 (11) : 948 - 955
  • [49] Adverse outcome following transfemoral endovascular stent-graft repair of an abdominal aortic aneurysm in a patient with severe liver dysfunction: Report of a case
    Nobusuke Ohara
    Tetsuro Miyata
    Hidemi Oshiro
    Hiroshi Shigematsu
    Takao Ohki
    Surgery Today, 2000, 30 : 764 - 767
  • [50] The effect of male-donor-only fresh frozen plasma on the incidence of acute lung injury following ruptured abdominal aortic aneurysm repair
    S Wright
    S Athey
    A Leaver
    C Snowden
    D Roberts
    J Clarkson
    C Chapman
    J Wallis
    Critical Care, 11 (Suppl 2):