Adhesion and mechanical properties of nanocrystalline hydroxyapatite coating obtained by conversion of atomic layer-deposited calcium carbonate on titanium substrate

被引:19
作者
Avila, Inari [1 ]
Pantchev, Konstantin [1 ]
Holopainen, Jani [2 ]
Ritala, Mikko [2 ]
Tuukkanen, Juha [1 ]
机构
[1] Univ Oulu, Inst Canc Res & Translat Med, Med Res Ctr, Dept Anat & Cell Biol, Oulu, Finland
[2] Univ Helsinki, Dept Chem, POB 55, FI-00014 Helsinki, Finland
关键词
PULSED-LASER DEPOSITION; RESIDUAL-STRESS; BOND STRENGTH; THIN-FILMS; PLASMA; FUNDAMENTALS; IMPLANT; SPRAY; TESTS; PHASE;
D O I
10.1007/s10856-018-6121-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to evaluate the mechanical properties of nanocrystalline hydroxyapatite coating by tensile adhesion testing and scratch testing. The coating was manufactured on titanium substrate by converting atomic layer-deposited (ALD) calcium carbonate thin film in dilute phosphate solution. The tensile adhesion testing was performed with hydraulic testing device in accordance with ISO 4624 and ISO 16276-1. Scratch testing was done according to SFS-EN 13523-12 with spherical 10 A mu m scratching tip. Characterization of the samples was done with light and electron microscopy after which they were stained with alizarin red and the failure modes and loadings were analyzed. The highest obtained tensile adhesion value was 6.71 MPa produced with 4000 ALD cycles, converted to hydroxyapatite in alkaline solution, and annealed for 30 min in 700 A degrees C. The annealing improved the adhesion values by approximately 0.8 MPa, but examining the samples with electron microscopy showed intact coating in both annealed and non-annealed samples. Samples produced with 4000 cycles performed better in testing than 2000 cycle samples, and better adhesion was also achieved with alkaline conversion solution compared to neutral solution. [GRAPHICS] .
引用
收藏
页数:8
相关论文
共 47 条
[1]  
[Anonymous], 2014, STAND SPEC COMP HYDR
[2]   A comparative study of three adhesion tests (EN 5829 similar to ASTM C633, LASAT (LASer Adhesion Test), and bulge and blister test) performed on plasma sprayed copper deposited on aluminium 2017 substrates [J].
Arrigoni, M. ;
Barradas, S. ;
Braccini, A. ;
Dupeux, M. ;
Jeandin, M. ;
Boustie, M. ;
Bolis, C. ;
Berthe, L. .
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2006, 20 (05) :471-487
[3]   Bonding strength of fluoridated hydroxyapatite coatings: A comparative study on pull-out and scratch analysis [J].
Cheng, Kui ;
Ren, Changbao ;
Weng, Wenjian ;
Du, Piyi ;
Shen, Ge ;
Han, Gaorong ;
Zhang, Sam .
THIN SOLID FILMS, 2009, 517 (17) :5361-5364
[4]   A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem [J].
Coathup, MJ ;
Blunn, GW ;
Flynn, N ;
Williams, C ;
Thomas, NP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (01) :118-123
[5]  
de Sena LA, 2002, J BIOMED MATER RES, V60, P1
[6]   Pulsed laser deposition of hydroxyapatite thin films on Ti-6Al-4V: Effect of heat treatment on structure and properties [J].
Dinda, G. P. ;
Shin, J. ;
Mazumder, J. .
ACTA BIOMATERIALIA, 2009, 5 (05) :1821-1830
[7]   Morphology and immersion behavior of plasma-sprayed hydroxyapatite/bioactive glass coatings [J].
Ding, SJ ;
Ju, CP ;
Lin, JHC .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2000, 11 (03) :183-190
[8]   Hydroxyapatite coatings: a comparative study between plasma-spray and pulsed laser deposition techniques [J].
GarciaSanz, FJ ;
Mayor, MB ;
Arias, JL ;
Pou, J ;
Leon, B ;
PerezAmor, M .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (12) :861-865
[9]   Ti based biomaterials, the ultimate choice for orthopaedic implants - A review [J].
Geetha, M. ;
Singh, A. K. ;
Asokamani, R. ;
Gogia, A. K. .
PROGRESS IN MATERIALS SCIENCE, 2009, 54 (03) :397-425
[10]   Atomic Layer Deposition: An Overview [J].
George, Steven M. .
CHEMICAL REVIEWS, 2010, 110 (01) :111-131