Skin Patchable Sensor Surveillance for Continuous Glucose Monitoring

被引:36
|
作者
Manasa, G. [1 ]
Mascarenhas, Ronald J. [1 ]
Shetti, Nagaraj P. [2 ]
Malode, Shweta J. [2 ]
Mishra, Amit [3 ]
Basu, Soumen [4 ]
Aminabhavi, Tejraj M. [2 ]
机构
[1] St Josephs Coll Autonomous, Dept Chem, Electrochem Res Grp, Bangalore 560027, Karnataka, India
[2] KLE Technol Univ, Sch Adv Sci, Dept Chem, Hubballi 580031, Karnataka, India
[3] Inha Univ, Dept Chem Engn, Incheon 22212, South Korea
[4] Thapar Inst Engn & Technol, Sch Chem & Biochem, Patiala 147004, Punjab, India
关键词
continuous glucose monitoring; diabetes mellitus; skin patch sensors; tattoo sensors; microneedle; CARBON-PASTE ELECTRODE; DRUG-DELIVERY; BLOOD-GLUCOSE; IN-VIVO; TRANSDERMAL DELIVERY; MICRONEEDLE PATCHES; AMPEROMETRIC SENSOR; SENSITIVE VESICLES; BIOSENSORS; ARRAY;
D O I
10.1021/acsabm.1c01289
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Diabetes mellitus is a physiological and metabolic disorder affecting millions of people worldwide, associated with global morbidity, mortality, and financial expenses. Long-term complications can be avoided by frequent, continuous self-monitoring of blood glucose. Therefore, this review summarizes the current state-of-art glycemic control regimes involving measurement approaches and basic concepts. Following an introduction to the significance of continuous glucose sensing, we have tracked the evolution of glucose monitoring devices from minimally invasive to non-invasive methods to present an overview of the spectrum of continuous glucose monitoring (CGM) technologies. The conveniences, accuracy, and cost-effectiveness of the real-time CGM systems (rt-CGMs) are the factors considered for discussion. Transdermal biosensing and drug delivery routes have recently emerged as an innovative approach to substitute hypodermal needles. This work reviews skin-patchable glucose monitoring sensors for the first time, providing specifics of all the major findings in the past 6 years. Skin patch sensors and their progressive form, i.e., microneedle (MN) array sensory and delivery systems, are elaborated, covering self-powered, enzymatic, and non-enzymatic devices. The critical aspects reviewed are material design and assembly techniques focusing on flexibility, sensitivity, selectivity, biocompatibility, and user-end comfort. The review highlights the advantages of patchable MNs' multi-sensor technology designed to maintain precise blood glucose levels and administer diabetes drugs or insulin through a "sense and act" feedback loop. Subsequently, the limitations and potential challenges encountered from the MN array as rt-CGMs are listed. Furthermore, the current statuses of working prototype glucose-responsive "closed-loop" insulin delivery systems are discussed. Finally, the expected future developments and outlooks in clinical applications are discussed.
引用
收藏
页码:945 / 970
页数:26
相关论文
共 50 条
  • [21] The Benefits of Continuous Glucose Monitoring in Pregnancy
    Yoo, Jee Hee
    Kim, Jae Hyeon
    ENDOCRINOLOGY AND METABOLISM, 2023, 38 (05) : 472 - 481
  • [22] Continuous Glucose Monitoring Enabled by Fluorescent Nanodiamond Boronic Hydrogel
    Zhang, Jian
    Zheng, Yongjun
    Lee, Jimmy
    Hoover, Alex
    King, Sarah Ann
    Chen, Lifeng
    Zhao, Jing
    Lin, Qiuning
    Yu, Cunjiang
    Zhu, Linyong
    Wu, Xiaoyang
    ADVANCED SCIENCE, 2023, 10 (07)
  • [23] Technological Advances of Wearable Device for Continuous Monitoring of In Vivo Glucose
    Huang, Xinshuo
    Yao, Chuanjie
    Huang, Shuang
    Zheng, Shantao
    Liu, Zhengjie
    Liu, Jing
    Wang, Ji
    Chen, Hui-jiuan
    Xie, Xi
    ACS SENSORS, 2024, 9 (03) : 1065 - 1088
  • [24] Impedance-based polymer microneedle patch sensor for continuous interstitial fluid glucose monitoring
    Piao, Honglin
    Choi, Yong-Ho
    Kim, Jaehyun
    Park, Daerl
    Lee, Jia
    Khang, Dahl-Young
    Choi, Heon-Jin
    BIOSENSORS & BIOELECTRONICS, 2024, 247
  • [25] Clinical Evaluation of a Photonic Crystal Sensor for Glucose Monitoring in Urine
    Lan, Yunhe
    Xue, Min
    Qiu, Lili
    Meng, Zihui
    CHEMISTRYSELECT, 2019, 4 (21): : 6547 - 6551
  • [26] Evaluation of sensor sites for continuous glucose monitoring in cats with diabetes mellitus
    Hafner, Michaela
    Lutz, Thomas A.
    Reusch, Claudia E.
    Zini, Eric
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2013, 15 (02) : 117 - 123
  • [27] Continuous glucose monitoring
    Lewis, Dana M.
    Oser, Tamara K.
    Wheeler, Benjamin J.
    BMJ-BRITISH MEDICAL JOURNAL, 2023, 380
  • [28] Estimating Plasma Glucose from Interstitial Glucose: The Issue of Calibration Algorithms in Commercial Continuous Glucose Monitoring Devices
    Rossetti, Paolo
    Bondia, Jorge
    Vehi, Josep
    Fanelli, Carmine G.
    SENSORS, 2010, 10 (12) : 10936 - 10952
  • [29] Effect of Subcutaneous Glucose Sensor Implantation on Skin mRNA Expression in Pigs
    Kvist, Peter Helding
    Iburg, Tine
    Dawson, Harry Dale
    Jensen, Henrik Elvang
    DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (10) : 791 - 799
  • [30] Continuous glucose monitoring in persons with type 2 diabetes not using insulin
    Cowart, Kevin
    Updike, Wendy H.
    Franks, Rachel