Development and Validation of a Method for Simultaneous Estimation of Sitagliptin and Ertugliflozin in Rat Plasma by LC-MS method

被引:3
作者
Rao, Pallepogu Venkateswara [1 ]
Rao, Atmakuri Lakshmana [2 ]
Prasad, Sahini Venkata Uma Maheswara [1 ]
机构
[1] Jawaharlal Nehru Technol Univ, Sch Pharm, Kakinada 533003, AP, India
[2] Vallabhaneni Venkatadri Inst Pharmaceut Sci, Gudlavalleru 521356, AP, India
关键词
Development; validation; sitagliptin; ertugliflozin; rat plasma; LC-MS; MS; TANDEM MASS-SPECTROMETRY; ALPHA-HYDROXYMETOPROLOL; LIQUID-CHROMATOGRAPHY; O-DESMETHYLMETOPROLOL; PHARMACOKINETICS; METFORMIN; INHIBITOR; METABOLITES; METOPROLOL; EXCRETION;
D O I
10.2174/1573412916999200630123120
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: The development of sound bioanalytical LC-MS (liquid chromatography-mass spectroscopy) method(s) is of paramount importance during the process of drug discovery, development and culminating in a marketing approval. The use of oral antidiabetic agents has been increased significantly from the last decades and till now no bioanalytical method is available for quantitation of sitagliptin (SG) and ertugliflozin (EG) in biological matrix which can be applied to pharmacokinetic studies using LC-MS/MS. Objective: To develop a new, rapid and sensitive LC-MS/MS method for the simultaneous estimation of sitagliptin (SG) and ertugliflozin (EG) in rat plasma by Liquid-Liquid Extraction method (LLE) using deutereated sitagliptin (SGd6) and ertugliflozin (EGd6). Methods: Chromatographic separation was carried out on a reverse phase Waters, Xetrra C18 (150mm x 4.6mm, 2 mu m) column using a mixture of acetonitrile and OPA buffer (50:50v/v) at a flow rate of 1ml/min in isocratic mode. Quantification was achieved using an electrospray ion interface operating in positive mode, under Multiple Reaction Monitoring (MRM) conditions. Results: The method showed excellent linearity over the concentration range of 5.00- 75.00pg/mL for sitagliptin and 0.75- 11.35pg/mL ertugliflozin. The intra-batch and inter batch precision (%CV) was <= 4.3% and matrix effect (%CV) was 0.02% and 0.12% for sitagliptin at HQC and LQC, respectively. Matrix effect (%CV) was 0.08% and 0.33% for ertugliflozin at HQC and LQC, respectively. Conclusion: The simplicity of the method allows for application in laboratories, presents a valuable tool for pharmacokinetic studies. The particular assay has been proficiently put on pharmacokinetic study in rats subjects.
引用
收藏
页码:1060 / 1074
页数:15
相关论文
共 50 条
  • [21] Design of experiment-based LC-MS/MS method development for simultaneous estimation of nateglinide and metformin hydrochloride in rat plasma
    Patel, Dhrumi
    Vora, Amisha
    Wairkar, Sarika
    Mayur, Y. C.
    JOURNAL OF MASS SPECTROMETRY, 2021, 56 (11):
  • [22] Development and validation of an LC-MS/MS method for the simultaneous quantification of seven constituents in rat plasma and application in a pharmacokinetic study of the Zaoren Anshen prescription
    Zhao, Ajing
    Zhang, Li
    Li, Rong
    Shang, Jiao
    Yi, Huihui
    Wang, Yuan
    Zhang, Dian
    Wang, Shixiang
    Fang, Minfeng
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (02)
  • [23] A simple and sensitive LC-MS/MS method for the determination of sotalol in rat plasma
    Feng, Zhiping
    Yu, Siyuan
    Liu, Wei
    Yang, Li
    Liu, Yang
    Zhai, Suodi
    Wang, Fang
    Zhang, Xianhua
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (08) : 1167 - 1172
  • [24] Development and Validation of a Method for Simultaneous Estimation of Metformin and Sitagliptin in Human Plasma by LC-MS-MS and Its Application in a Bioequivalence Study
    Reddy, Srinivasa
    Ahmed, Imran
    Ahmad, Iqbal
    Mukhopadhyay, Arindam
    Thangam, Saral
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (09) : 1549 - 1556
  • [25] Validated LC-MS/MS method for simultaneous determination of Dasatinib and Sitagliptin in rat plasma and its application to pharmacokinetic study
    Patel, Prinesh N.
    Samanthula, Gananadhamu
    Sridhar, Veeraraghavan
    Arla, Rambabu
    Varanasi, Kanthi Kiran V. S.
    Kumar, Swaroop V. V. S.
    ANALYTICAL METHODS, 2014, 6 (02) : 433 - 439
  • [26] Development and Application of a LC-MS/MS Method for the Determination of Fentanyl in Rat Plasma
    Chen, Sheng-yang
    Wang, Geng-fu
    Zhang, Yong-qiang
    Zhang, Xiao-ran
    Liu, Jun
    Tian, Jian-min
    Hu, Jie
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (01): : 51 - 55
  • [27] Development and Validation of an LC-MS/MS Method for Simultaneous Determination of Canagliflozin and Metformin HCl in Rat Plasma and its Application
    Nalawade, Vivek
    Dixit, Vaibhav A.
    Vora, Amisha
    Zade, Himashu
    CURRENT PHARMACEUTICAL ANALYSIS, 2020, 16 (06) : 752 - 762
  • [28] Simultaneous estimation of amlodipine and atenolol in human plasma: a sensitive LC-MS/MS method validation and its application to a clinical PK study
    Kallem, Raja Reddy
    Mullangi, Ramesh
    Hotha, Kishore Kumar
    Ravindranath, L. K.
    Spoorthy, Y. N.
    Seshagirirao, J. V. L. N.
    BIOANALYSIS, 2013, 5 (07) : 827 - 837
  • [29] Validation of an LC-MS/MS method for simultaneous quantification of abiraterone, enzalutamide and darolutamide in human plasma
    Buck, Stefan A. J.
    de Bruijn, Peter
    Ghobadi-Moghaddam-Helmantel, Inge M.
    Lam, Mei H.
    de Wit, Ronald
    Koolen, Stijn L. W.
    Mathijssen, Ron H. J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1225
  • [30] Development and validation of an LC-MS/MS method for simultaneous quantification of hesperidin and hesperetin in rat plasma for pharmacokinetic studies
    Lee, Jr-Ting
    Pao, Li-Heng
    Hsieh, Chang-Da
    Huang, Pei-Wei
    Hu, Oliver Yoa-Pu
    ANALYTICAL METHODS, 2017, 9 (22) : 3329 - 3337