Systematic error in automated in-tube solid-phase microextraction

被引:8
作者
Raghani, AR [1 ]
Schultz, KN [1 ]
机构
[1] Global Chem Proc R&D, Pharmacia Corp, Skokie, IL 60077 USA
关键词
solid-phase microextraction; in-tube solid-phase microextraction; automation; systematic errors; instrumentation; ranitidine;
D O I
10.1016/S0021-9673(03)00499-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The widely employed configuration for automated in-tube solid-phase microextraction (SPME) involves modification of a commercial liquid chromatographic autosampler into an automated extraction device. This popular configuration is demonstrated to result in an inherent systematic error in the quantitation of analyte in a given matrix. The source of error is traced to the accumulation of analyte in the extraction and the pre-extraction segment (i.e., sample loop, metering valve and tubing prior to the metering valve) of the autosampler where the analyte comes in contact with the residual mobile phase. This results in cross-contamination due to sample/mobile phase mixing. The quantity of analyte accumulated in these segments is shown to consistently increase with the increasing number of draw/eject cycles. As a result of the accumulation, the amount of analyte recorded leads to inaccurate quantitative information, leading to overestimation of the limit of detection and limit of quantitation, when automated in-tube SPME is employed as an approach for sample enrichment. Insertion of a 100-mul air plug prior to extraction step was able to significantly minimize sample/mobile phase mixing of analyte with the residual mobile phase in the pre-extraction and extraction step, thus minimizing the systematic error. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 15 条
[1]   Advances in sample preparation in electromigration, chromatographic and mass spectrometric separation methods [J].
Gilar, M ;
Bouvier, ESP ;
Compton, BJ .
JOURNAL OF CHROMATOGRAPHY A, 2001, 909 (02) :111-135
[2]  
GUO Y, 2000, J MICROCOLUMN SEP, V12, P125
[3]   Automated in-tube solid-phase microextraction-liquid chromatography-electrospray ionization mass spectrometry for the determination of ranitidine [J].
Kataoka, H ;
Lord, HL ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY B, 1999, 731 (02) :353-359
[4]  
Kataoka H, 2002, J SEP SCI, V25, P77, DOI 10.1002/1615-9314(20020101)25:1/2<77::AID-JSSC77>3.0.CO
[5]  
2-3
[7]  
KATAOKA H, 1999, CHROMATOGRAPHY, V20, P142
[8]   Bio-compatible in-tube solid-phase microextraction capillary for the direct extraction and high-performance liquid chromatographic determination of drugs in human serum [J].
Mullett, WM ;
Levsen, K ;
Lubda, D ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :325-334
[9]   In-tube molecularly imprinted polymer solid-phase microextraction for the selective determination of propranolol [J].
Mullett, WM ;
Martin, P ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2383-2389
[10]   Verapamil drug metabolism studies by automated in-tube solid phase microextraction [J].
Walles, M ;
Mullett, WM ;
Levsen, K ;
Borlak, J ;
Wünsch, G ;
Pawliszyn, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (02) :307-319