Quantitative structure-(chromatographic) retention relationships

被引:347
作者
Heberger, Karoly [1 ]
机构
[1] Hungarian Acad Sci, Chem Res Ctr, POB 17, H-1525 Budapest, Hungary
关键词
QSRR; QRAR; QSERR; gas chromatography; column liquid chromatography; planar chromatography; micellar liquid chromatography; affinity chromatography; chemometrics; modeling;
D O I
10.1016/j.chroma.2007.03.108
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Since the pioneering works of Kaliszan (R. Kaliszan, Quantitative Structure-Chromatographic Retention Relationships, Wiley, New York, 1987; and R. Kaliszan, Structure and Retention in Chromatography. A Chemometric Approach, Harwood Academic, Amsterdam, 1997) no comprehensive summary is available in the field. Present review covers the period of 1996-August 2006. The sources are grouped according to the special properties of kinds of chromatography: Quantitative structure-retention relationship in gas chromatography, in planar chromatography, in column liquid chromatography, in micellar liquid chromatography, affinity chromatography and quantitative structure enantioselective retention relationships. General tendencies, misleading practice and conclusions, validation of the models, suggestions for future works are summarized for each sub-field. Some straightforward applications are emphasized but standard ones. The sources and the model compounds, descriptors, predicted retention data, modeling methods and indicators of their performance, validation of models, and stationary phases are collected in the tables. Some important conclusions are: Not all physicochernical descriptors correlate with the retention data strongly; the heat of formation is not related to the chromatographic retention. It is not appropriate to give the errors of Kovats indices in percentages. The apparently low values (1-3%) can disorient the reviewers and readers. Contemporary mean interlaboratory reproducibility of Kovats indices are about 5-10 i.u. for standard non polar phases and 10-25 i.u. for standard polar phases. The predictive performance of QSRR models deteriorates as the polarity of GC stationary phase increases. The correlation coefficient alone is not a particularly good indicator for the model performance. Residuals are more useful than plots of measured and calculated values. There is no need to give the retention data in a form of an equation if the numbers of compounds are small. The domain of model applicability of models should be given in all cases. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:273 / 305
页数:33
相关论文
共 411 条
[1]   Pre-processing of three-way data by pulse-coupled neural networks -: an imaging approach [J].
Åberg, KM ;
Jacobsson, SP .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2001, 57 (01) :25-36
[2]   Determination of sets of solute descriptors from chromatographic measurements [J].
Abraham, MH ;
Ibrahim, A ;
Zissimos, AM .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1037 (1-2) :29-47
[3]   Determination of solute lipophilicity, as log P(octanol) and log P(alkane) using poly(styrene-divinylbenzene) and immobilised artificial membrane stationary phases in reversed-phase high-performance liquid chromatography [J].
Abraham, MH ;
Chadha, HS ;
Leitao, ARE ;
Mitchell, RC ;
Lambert, WJ ;
Kaliszan, R ;
Nasal, A ;
Haber, P .
JOURNAL OF CHROMATOGRAPHY A, 1997, 766 (1-2) :35-47
[4]   Quantitative study of the structure-retention index relationship in the imine family [J].
Acevedo-Martínez, J ;
Escalona-Arranz, JC ;
Villar-Rojas, A ;
Téllez-Palmero, F ;
Pérez-Rosés, R ;
González, L ;
Carrasco-Velar, R .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) :238-244
[5]   Quantitative structure-capillary column gas chromatographic retention time relationships for natural sterols (trimethylsilyl ethers) from olive oil [J].
Acuña-Cueva, R ;
Hueso-Ureña, F ;
Cabeza, NAI ;
Jiménez-Pulido, SB ;
Moreno-Carretero, MN ;
Martos, JMM .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2000, 77 (06) :627-630
[6]   Test analytes for studies of the molecular mechanism of chromatographic separations by quantitative structure-retention relationships [J].
Al-Haj, MA ;
Kaliszan, R ;
Nasal, A .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :2976-2985
[7]   Quantitative structure-retention relationships with model analytes as a means of an objective evaluation of chromatographic columns [J].
Al-Haj, MA ;
Kaliszan, R ;
Buszewski, B .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (01) :29-38
[8]   Mechanism of separation on cholesterol-silica stationary phase for high-performance liquid chromatography as revealed by analysis of quantitative structure-retention relationships [J].
Al-Haj, MA ;
Haber, P ;
Kaliszan, R ;
Buszewski, B ;
Jezierska, M ;
Chilmonzyk, Z .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) :721-728
[9]   The molecular retention mechanism in reversed-phase liquid chromatography of meso-ionic compounds by quantitative structure - Retention relationships (QSRR) [J].
Almeida, TMG ;
Leitao, A ;
Montanari, MLC ;
Montanari, CA .
CHEMISTRY & BIODIVERSITY, 2005, 2 (12) :1691-1700
[10]  
Altomare C, 1996, CHIRALITY, V8, P556