Comparison of air-conditioning systems with bottom-supply and side-supply modes in a typical office room

被引:30
作者
Zheng, Chenxiao [1 ,2 ]
You, Shijun [1 ,2 ]
Zhang, Huan [1 ,2 ]
Zheng, Wandong [1 ,3 ]
Zheng, Xuejing [1 ]
Ye, Tianzheng [1 ]
Liu, Zeqin [4 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300350, Peoples R China
[2] Tianjin Univ, MOE, Key Lab Efficient Utilizat Low & Medium Grade Ene, Tianjin 300350, Peoples R China
[3] China Acad Bldg Res, State Key Lab Bldg Safety & Built Environm, Beijing 100013, Peoples R China
[4] Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin 300134, Peoples R China
关键词
Air-conditioning system; Air supply mode; Thermal comfort; Energy utilization efficiency; THERMAL-COMFORT; DISPLACEMENT VENTILATION; UNDER-FLOOR; OPEN-PLAN; ENERGY; PERFORMANCE; TEMPERATURE; SIMULATION; TECHNOLOGIES; ENVIRONMENT;
D O I
10.1016/j.apenergy.2017.07.078
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The growing energy consumption and thermal comfort of an air-conditioned room have attracted increasing public attention. As such, the performance of air-conditioning systems with two air supply modes for a simplified office room was studied by numerical simulation and physical experiment. An experimental investigation was developed in an environmental chamber to validate the simulation model. Numerical investigation was carried out subsequently for an office setting by the validated CFD model. The indoor thermal environment, human thermal comfort and energy utilization efficiency of two air supply modes were analyzed and compared in this study. The results showed that under both air supply modes, thermal stratification occurred in the model room, and the air flow velocity in the occupied zone was low. In addition, the results indicated that under 21 degrees C supply temperature, the air-conditioning system with bottom-supply mode provided better indoor thermal comfort of the occupied zone, but the energy consumption was higher than the side-supply mode.
引用
收藏
页码:304 / 311
页数:8
相关论文
共 37 条
  • [1] Optimized performance of displacement ventilation aided with chair fans for comfort and indoor air quality
    Abou Hweij, Walid
    Ghaddar, Nesreen
    Ghali, Kamel
    Habchi, Carine
    [J]. ENERGY AND BUILDINGS, 2016, 127 : 907 - 919
  • [2] Energy analysis of under-floor air distribution (UFAD) system: An office building case study
    Alajmi, Ali F.
    Abou-Ziyan, Hosny Z.
    El-Amer, Wid
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 73 : 78 - 85
  • [3] Experimental assessment of the energy performance of a hybrid desiccant cooling system and comparison with other air-conditioning technologies
    Angrisani, Giovanni
    Roselli, Carlo
    Sasso, Maurizio
    [J]. APPLIED ENERGY, 2015, 138 : 533 - 545
  • [4] [Anonymous], 2010, ASHRAE Standard 55-2010: Thermal Environmental Conditions for Human Occupancy
  • [5] [Anonymous], 2013, 1132013 ASHRAE
  • [6] [Anonymous], THESIS
  • [7] [Anonymous], THESIS
  • [8] [Anonymous], THERMAL COMFORT
  • [9] [Anonymous], CIVIL BUILDING AIR C
  • [10] [Anonymous], CFX HDB