Evaluation of Reproducibility of Diffusion Tensor Imaging in the Brachial Plexus at 3.0 T

被引:29
作者
Ho, Michael J. [1 ]
Manoliu, Andrei [1 ]
Kuhn, Felix Pierre [1 ]
Stieltjes, Bram [2 ]
Klarhofer, Markus [3 ]
Feiweier, Thorsten [3 ]
Marcon, Magda [1 ]
Andreisek, Gustav [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Zurich, Switzerland
[2] Univ Basel, Dept Radiol, Basel, Switzerland
[3] Siemens Healthcare AG, Zurich, Switzerland
关键词
MRN; DTI peripheral nerves; brachial plexus; CERVICAL-SPINAL-CORD; MR-NEUROGRAPHY; MEDIAN NERVE; WHITE-MATTER; TRACTOGRAPHY; AGREEMENT; ROOTS; INTRA; DTI;
D O I
10.1097/RLI.0000000000000363
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to evaluate the reproducibility of 3 T magnetic resonance imaging diffusion tensor imaging (DTI) of the brachial plexus in healthy subjects. Methods: Ten healthy volunteers were included, and morphological and DTI sequences of the nerve roots of the brachial plexus from C5 to T1 of both sides were repeatedly acquired on a 3 T magnetic resonance system (MAGNETOM Skyra; Siemens Healthcare, Erlangen, Germany). A prototype diffusion-weighted single-shot echo-planar imaging sequence-enabling slice-specific shim adjustments was performed with b-values of 0 and 800 s/mm(2) in 30 gradient directions, resulting in an acquisition time of about 6 minutes each in axial orientation. Between scans, subjects were moved and repositioned in the scanner, coils were reinserted, and new localizers were acquired. Image analysis was performed using MITK Diffusion software toolkit. Two independent readers performed diffusion data postprocessing, and regions of interest (ROIs) were set on the proximal postganglionic trunk at each spinal level, bilaterally to obtain values for fractional anisotropy (FA) and mean diffusivity (MD). Interreader and intrareader agreement as well as test-retest reproducibility of DTI metrics were assessed. Results: Intraclass correlation coefficients (ICCs) for interreader and intrareader agreement did not differ significantly between measurements for FA and MD. In particular, ICCs for interreader agreement of FA ranged from 0.741 to 0.961 and that of MD ranged from 0.802 to 0.998, and ICCs for intrareader agreement of FA ranged from 0.759 to 0.949 and that ofMD ranged from 0.796 to 0.998. The test-retest reproducibility of DTI metrics showed an overall moderate to strong correlation (r > 0.707), with few minor exceptions, for both FA and MD values. Conclusions: Diffusion tensor imaging metrics in the brachial plexus are reproducible. Future applications of DTI for a possible clinical use should be further investigated.
引用
收藏
页码:482 / 487
页数:6
相关论文
共 27 条
  • [1] Inter- and intra-rater reliability of diffusion tensor imaging parameters in the normal pediatric spinal cord
    Barakat, Nadia
    Shah, Pallav
    Faro, Scott H.
    Gaughan, John P.
    Middleton, Devon
    Mulcahey, M. J.
    Mohamed, Feroze B.
    [J]. WORLD JOURNAL OF RADIOLOGY, 2015, 7 (09): : 279 - 285
  • [2] The basis of anisotropic water diffusion in the nervous system - a technical review
    Beaulieu, C
    [J]. NMR IN BIOMEDICINE, 2002, 15 (7-8) : 435 - 455
  • [3] Dynamic shim updating: A new approach towards optimized whole brain shimming
    Blamire, AM
    Rothman, DL
    Nixon, T
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) : 159 - 165
  • [4] Establishing the reproducibility of two approaches to quantify white matter tract integrity in stroke
    Borich, Michael R.
    Wadden, Katie P.
    Boyd, Lara A.
    [J]. NEUROIMAGE, 2012, 59 (03) : 2393 - 2400
  • [5] Diffusion tensor imaging of the cervical spinal cord in healthy adult population: normative values and measurement reproducibility at 3T MRI
    Brander, Antti
    Koskinen, Eerika
    Luoto, Teemu M.
    Hakulinen, Ullamari
    Helminen, Mika
    Savilahti, Sirpa
    Ryymin, Pertti
    Dastidar, Prasun
    Ohman, Juha
    [J]. ACTA RADIOLOGICA, 2014, 55 (04) : 478 - 485
  • [6] Diffusion Tensor Imaging of Symptomatic Nerve Roots in Patients with Cervical Disc Herniation
    Chen, Yue-Yao
    Lin, Xiao-Feng
    Zhang, Fang
    Zhang, Xiang
    Hu, Hui-Jun
    Wang, Dong-Ye
    Lu, Lie-Jing
    Shen, Jun
    [J]. ACADEMIC RADIOLOGY, 2014, 21 (03) : 338 - 344
  • [7] High-Resolution 3T MR Neurography of the Brachial Plexus and Its Branches, with Emphasis on 3D Imaging
    Chhabra, A.
    Thawait, G. K.
    Soldatos, T.
    Thakkar, R. S.
    Del Grande, F.
    Chalian, M.
    Carrino, J. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (03) : 486 - 497
  • [8] MR Neurography: Past, Present, and Future
    Chhabra, Avneesh
    Andreisek, Gustav
    Soldatos, Theodoros
    Wang, Kenneth C.
    Flammang, Aaron J.
    Belzberg, Allan J.
    Carrino, John A.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : 583 - 591
  • [9] Magnetic resonance neurography for the evaluation of peripheral nerve, brachial plexus, and nerve root disorders Clinical article
    Du, Rose
    Auguste, Kurtis I.
    Chin, Cynthia T.
    Engstrom, John W.
    Weinstein, Philip R.
    [J]. JOURNAL OF NEUROSURGERY, 2010, 112 (02) : 362 - 371
  • [10] Feiweier T, 2014, US patent, Patent No. [8 633 690 B2, 8633690]