Second harmonic generation imaging via nonlinear endomicroscopy

被引:55
作者
Bao, Hongchun [1 ]
Boussioutas, Alex [2 ,3 ]
Jeremy, Reynolds [2 ]
Russell, Sarah [1 ,2 ]
Gu, Min [1 ]
机构
[1] Swinburne Univ Technol, Ctr Microphoton, Fac Engn & Ind Sci, Hawthorn, Vic 3122, Australia
[2] Peter MacCallum Canc Ctr, Melbourne, Vic 3002, Australia
[3] Univ Melbourne, Dept Med RMH WH, Western Hosp, Footscray, Vic 3011, Australia
来源
OPTICS EXPRESS | 2010年 / 18卷 / 02期
基金
澳大利亚研究理事会;
关键词
PHOTONIC CRYSTAL FIBER; MICROSCOPY; COLLAGEN; COUPLER; MODULATION;
D O I
10.1364/OE.18.001255
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A compact endomicroscope is the only solution for transferring second harmonic generation (SHG) imaging into in vivo imaging and real time monitoring the content and structure of collagen. This is important for early diagnoses of different diseases associated with collagen change. A compact nonlinear endomicroscope using a double clad fiber (DCF) is newly employed in SHG imaging. The experiment shows the core of the DCF can maintain the linear polarization of the excitation laser beam in particular directions, and the degree of polarization of the excitation laser beam directly affects signal to noise ratio of SHG imaging. The nonlinear endomicroscope can display clear three dimensional (3D) SHG images of mouse tail tendon without the aid of contrast agents, which reveals the collagen fiber structure at different depths. The high resolution of SHG imaging from the endomicroscope shows that SHG imaging can reveal additional information about the orientation and degree of organisation of proteins and collagen fibers than two-photon-excited fluorescence imaging. Therefore SHG imaging offers endomicroscopy with additional channel of imaging for understanding more about biological phenomena. (C) 2010 Optical Society of America
引用
收藏
页码:1255 / 1260
页数:6
相关论文
共 18 条
[1]   Fast handheld two-photon fluorescence microendoscope with a 475 μm X 475 μm field of view for in vivo imaging [J].
Bao, Hongchun ;
Allen, John ;
Pattie, Robert ;
Vance, Rod ;
Gu, Min .
OPTICS LETTERS, 2008, 33 (12) :1333-1335
[2]   Reduction of self-phase modulation in double-clad photonic crystal fiber for nonlinear optical endoscopy [J].
Bao, Hongchun ;
Gu, Min .
OPTICS LETTERS, 2009, 34 (02) :148-150
[3]   Compact two-photon fluorescence microscope based on a single-mode fiber coupler [J].
Bird, D ;
Gu, M .
OPTICS LETTERS, 2002, 27 (12) :1031-1033
[4]   Dynamic imaging of collagen and its modulation in tumors in vivo using second-harmonic generation [J].
Brown, E ;
McKee, T ;
diTomaso, E ;
Pluen, A ;
Seed, B ;
Boucher, Y ;
Jain, RK .
NATURE MEDICINE, 2003, 9 (06) :796-800
[5]   Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms [J].
Campagnola, PJ ;
Loew, LM .
NATURE BIOTECHNOLOGY, 2003, 21 (11) :1356-1360
[6]   Uniform polarity microtubule assemblies imaged in native brain tissue by second-harmonic generation microscopy [J].
Dombeck, DA ;
Kasischke, KA ;
Vishwasrao, HD ;
Ingelsson, M ;
Hyman, BT ;
Webb, WW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (12) :7081-7086
[7]   Polarisation characteristics of a 1x2 fibre coupler under femtosecond pulsed and continuous wave illumination [J].
Fu, L ;
Gan, XS ;
Bird, D ;
Gu, M .
OPTICS AND LASER TECHNOLOGY, 2005, 37 (06) :494-497
[8]   Use of a single-mode fiber coupler for second-harmonic-generation microscopy [J].
Fu, L ;
Gan, XS ;
Gu, M .
OPTICS LETTERS, 2005, 30 (04) :385-387
[9]   Polarization anisotropy in fiber-optic second harmonic generation microscopy [J].
Fu, Ling ;
Gu, Min .
OPTICS EXPRESS, 2008, 16 (07) :5000-5006
[10]   Double-clad photonic crystal fiber coupler for compact nonlinear optical microscopy imaging [J].
Fu, Ling ;
Gu, Min .
OPTICS LETTERS, 2006, 31 (10) :1471-1473