The improved fault location method based on natural frequency in MMC-HVDC grid by combining FFT and MUSIC algorithms

被引:22
作者
He, Jiawei [1 ]
Li, Bin [1 ]
Sun, Qiang [1 ]
Li, Ye [1 ]
Lyu, Huijie [1 ]
Wang, Wenbo [1 ]
Xie, Zhongrun [1 ]
机构
[1] Tianjin Univ, Minist Educ, Key Lab Smart Grid, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
MMC-HVDC grid; Fault location; Short data window; Second natural frequency; MUSIC false frequency phenomenon; INJECTION;
D O I
10.1016/j.ijepes.2021.107816
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The fast and accurate fault location is extremely important for effective fault clearance in the power system. And in HVDC grid, the natural-frequency based fault location method is quite promising. Therefore, in this paper, the applicability of the traditional natural-frequency based method in MMC-HVDC grid is analyzed. Then the improved method suitable for MMC-HVDC grid is proposed. In the proposed method, the second natural frequency is discriminated and extracted to calculate the fault distance, because the first natural frequency is very low and used data window is very short in MMC-HVDC grid. In addition, the scheme combinedly utilizing FFT and MUSIC algorithms is designed, to avoid influence of traditional MUSIC false frequency phenomenon. A four terminal meshed dc grid model is built based on PSCAD/EMTDC, and the simulation cases are carried out to verify the correctness of theoretical analysis and superiorities of proposed method. Compared with traditional method, the proposed one calculates fault distance based on a shorter data window, thus being more suitable for MMC-HVDC grid. And the influence of the MUSIC false frequency phenomenon is avoided, further guaranteeing the fault location accuracy.
引用
收藏
页数:10
相关论文
共 22 条
[1]   Fault location on multi-terminal DC systems using synchronized current measurements [J].
Azizi, Sadegh ;
Afsharnia, Saeed ;
Sanaye-Pasand, Majid .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 63 :779-786
[2]   Single pole-to-ground fault location method for MMC-HVDC system using active pulse [J].
Bi, Tianshu ;
Wang, Shuai ;
Jia, Ke .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (02) :272-278
[3]   VSC-Based HVDC Power Transmission Systems: An Overview [J].
Flourentzou, Nikolas ;
Agelidis, Vassilios G. ;
Demetriades, Georgios D. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (3-4) :592-602
[4]  
Hafner J., 2011, P CIGRE BOL S, P13
[5]   Technical Assessment of Load Commutation Switch in Hybrid HVDC Breaker [J].
Hassanpoor, Arman ;
Haefner, Juergen ;
Jacobson, Bjoern .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (10) :5393-5400
[6]  
He J. W., 2021, INT J ELEC POWER, V134
[7]   Natural Frequency-Based Line Fault Location in HVDC Lines [J].
He, Zheng-You ;
Liao, Kai ;
Li, Xiao-Peng ;
Lin, Sheng ;
Yang, Jian-Wei ;
Mai, Rui-Kun .
IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (02) :851-859
[8]  
Li B., ELECTR POW SYST RES, V192, P2021
[9]   A novel restart control strategy for the MMC-based HVDC transmission system [J].
Li, Bin ;
He, Jiawei ;
Li, Ye ;
Hong, Chao ;
Zhang, Ye .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 99 :465-473
[10]   A Pole-to-Pole Short-Circuit Fault Current Calculation Method for DC Grids [J].
Li, Chengyu ;
Zhao, Chengyong ;
Xu, Jianzhong ;
Ji, Yuke ;
Zhang, Fan ;
An, Ting .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (06) :4943-4953