Monte Carlo characterization of the M-19 high dose rate Iridium-192 brachytherapy source

被引:26
作者
Medich, David C.
Munro, John J., III
机构
[1] Univ Massachusetts, Radiat Lab, Lowell, MA 01854 USA
[2] Source Prod & Equipment Co Inc, St Rose, LA 70087 USA
关键词
brachytherapy; iridium-192; radiation dosimetry; Monte Carlo; MCNP;
D O I
10.1118/1.2733809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The MCNP5 Monte Carlo code was used to simulate the dosimetry of an M-19 iridium-192 high dose rate brachytherapy source in both air/vacuum and water environments with the in-air photon spectrum filtered to remove low-energy photons below delta= 10 keV. Dosimetric data was organized into an away-along table and was used to derive the updated AAPM Task Group Report No. 43 (TG-43U1) parameters including S-K, D(r, theta), Lambda, g(L)(r), F(r, theta), phi(an)(r), and (phi) over bar (an) and their respective statistical uncertainties. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1999 / 2006
页数:8
相关论文
共 50 条
[41]   Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE [J].
Almansa, Julio F. ;
Guerrero, Rafael ;
Torres, Javier ;
Lallena, Antonio M. .
BRACHYTHERAPY, 2017, 16 (05) :1073-1080
[42]   Verification of evaluation accuracy of absorbed dose in the dose-evaluation system for iridium-192 brachytherapy for treatment of keloids [J].
Ohta, M. ;
Nakao, N. ;
Kuribayashi, S. ;
Hayashizaki, N. .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (02)
[43]   Combined treatment with temporary short-term high dose rate Iridium-192 brachytherapy and external beam radiotherapy for irradiation of localized prostatic carcinoma [J].
Borghede, G ;
Hedelin, H ;
Holmang, S ;
Johansson, KA ;
Aldenborg, F ;
Pettersson, S ;
Sernbo, G ;
Wallgren, A ;
Mercke, C .
RADIOTHERAPY AND ONCOLOGY, 1997, 44 (03) :237-244
[44]   Monte Carlo Evaluation for the Effect of Positional Inaccuracy of Source on Patient's Dose in High-Dose-Rate Brachytherapy [J].
Lee, Kyung Ja ;
An, So Hyun ;
Lee, Rena .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (06) :2361-2365
[45]   Efficacy of Nanoparticles in dose enhancement with high dose rate of Iridium-192 and Cobalt-60 radionuclide sources in the Treatment of Cancer: A systematic review [J].
Gebremariam, Tsige Y. ;
Geraily, Ghazale ;
Arero, Amanuel G. ;
Gholami, Somayeh .
JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 :S477-S484
[46]   High dose-rate afterloading 192Iridium prostate brachytherapy:: Feasibility report [J].
Mate, TP ;
Gottesman, JE ;
Hatton, J ;
Gribble, M ;
Van Hollebeke, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (03) :525-533
[47]   ENDOBRONCHIAL BRACHYTHERAPY IN THE TREATMENT OF LUNG AND PRIMARY TRACHEAL CANCER: ELEVEN YEARS' EXPERIENCE WITH IRIDIUM-192 HIGH-DOSE RADIATION [J].
Grazziotin, Rachele Z. ;
Reisner, Marcio L. ;
Toscano, Edson ;
Sousa, Aureliano ;
Viegas, Celia M. P. ;
Araujo, Carlos M. M. ;
Zamboni, Mauro .
JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) :S835-S836
[48]   Dose rate table for a 32P intravascular brachytherapy source from Monte Carlo calculations [J].
Bohm, TD ;
Mourtada, FA ;
Das, RK .
MEDICAL PHYSICS, 2001, 28 (08) :1770-1775
[49]   Irradiation of localized prostatic carcinoma with a combination of high dose rate iridium-192 brachytherapy and external beam radiotherapy with three target definitions and dose levels inside the prostate gland [J].
Borghede, G ;
Hedelin, H ;
Holmang, S ;
Johansson, KA ;
Sernbo, G ;
Mercke, C .
RADIOTHERAPY AND ONCOLOGY, 1997, 44 (03) :245-250
[50]   Monte Carlo characterization of high atomic number inorganic scintillators for in vivo dosimetry in 192Ir brachytherapy [J].
Kaveckyte, Vaiva ;
Jorgensen, Erik B. ;
Kertzscher, Gustavo ;
Johansen, Jacob G. ;
Carlsson Tedgren, Asa .
MEDICAL PHYSICS, 2022, 49 (07) :4715-4730