Monte Carlo characterization of the M-19 high dose rate Iridium-192 brachytherapy source

被引:26
作者
Medich, David C.
Munro, John J., III
机构
[1] Univ Massachusetts, Radiat Lab, Lowell, MA 01854 USA
[2] Source Prod & Equipment Co Inc, St Rose, LA 70087 USA
关键词
brachytherapy; iridium-192; radiation dosimetry; Monte Carlo; MCNP;
D O I
10.1118/1.2733809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The MCNP5 Monte Carlo code was used to simulate the dosimetry of an M-19 iridium-192 high dose rate brachytherapy source in both air/vacuum and water environments with the in-air photon spectrum filtered to remove low-energy photons below delta= 10 keV. Dosimetric data was organized into an away-along table and was used to derive the updated AAPM Task Group Report No. 43 (TG-43U1) parameters including S-K, D(r, theta), Lambda, g(L)(r), F(r, theta), phi(an)(r), and (phi) over bar (an) and their respective statistical uncertainties. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1999 / 2006
页数:8
相关论文
共 50 条
  • [21] Dosimetric investigation of high dose rate Ir-192 source with Monte Carlo method
    Acun, H.
    Bozkurt, A.
    Kemikler, G.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2017, 15 (03): : 241 - 249
  • [22] Monte Carlo characterization of a new Yb-169 high dose rate source for brachytherapy application
    Cazeca, Mario J.
    Medich, David C.
    Munro, John J., III
    MEDICAL PHYSICS, 2010, 37 (03) : 1129 - 1136
  • [23] Monte Carlo characterization of 169Yb as a high-dose-rate source for brachytherapy application by FLUKA code
    Anjomrouz, Marzieh
    Sadeghi, Mahdi
    Haddadi, Asghar
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 196 - 205
  • [24] Dosimetry of indigenously developed Ir-192 high-dose rate brachytherapy source: An EGSnrc Monte Carlo study
    Sahoo, Sridhar
    Selvam, T. Palani
    Sharma, S. D.
    Das, Trupti
    Dey, A. C.
    Patil, B. N.
    Sastri, K. V. S.
    JOURNAL OF MEDICAL PHYSICS, 2016, 41 (02) : 115 - 122
  • [25] High-dose rate iridium-192 brachytherapy and external beam radiation therapy for prostate cancer with or without androgen ablation
    Chiang, PH
    Fang, FM
    Jong, WC
    Yu, TJ
    Chuang, YC
    Wang, HJ
    INTERNATIONAL JOURNAL OF UROLOGY, 2004, 11 (03) : 152 - 158
  • [26] Monte Carlo dosimetry of high dose rate gynecologic interstitial brachytherapy
    Desbiens, Maxime
    D'Amours, Michel
    Afsharpour, Hossein
    Verhaegen, Frank
    Lavallee, Marie-Claude
    Thibault, Isabelle
    Vigneault, Eric
    Beaulieu, Luc
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 425 - 429
  • [27] High dose-rate brachytherapy of prostate cancer utilising Iridium-192 after-loading technique:: Technical and methodological aspects
    Edgren, M.
    Ekelund, A. M.
    Albertsson, P.
    Lundberg, L. M.
    Ullen, A.
    Levitt, S.
    Nilsson, S.
    Lennernas, B.
    INTERNATIONAL JOURNAL OF ONCOLOGY, 2006, 29 (06) : 1517 - 1524
  • [28] Treatment of non-melanoma superficial skin cancer with custom-made wax moulds using Iridium-192 high-dose-rate brachytherapy source
    Shah, Kamran Ali
    Ahmad, Habib
    Khattak, Muhammad Rauf
    Ahmad, Misbah
    Javed, Nabila
    Shah, Syed Jawad Ali
    Shaheen, Wajeeha
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 53 - 59
  • [29] Radiation exposure to the kidney with interstitial iridium-192 high-dose-rate brachytherapy: Extent and rare morphologic changes of radiation nephropathy
    March, Christine
    Thormann, Maximilian
    Hass, Peter
    Seidensticker, Max
    Gross, Christian
    Omari, Jazan
    Pech, Maciej
    Damm, Robert
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2022, 14 (06) : 512 - 518
  • [30] Three-year results of treatment for prostate cancer with low-dose rate temporary iridium-192 brachytherapy
    Momma, T
    Saito, S
    Toya, K
    Yorozu, A
    Dokiya, T
    Murai, M
    INTERNATIONAL JOURNAL OF UROLOGY, 2006, 13 (03) : 218 - 223