Monte Carlo characterization of the M-19 high dose rate Iridium-192 brachytherapy source

被引:26
|
作者
Medich, David C.
Munro, John J., III
机构
[1] Univ Massachusetts, Radiat Lab, Lowell, MA 01854 USA
[2] Source Prod & Equipment Co Inc, St Rose, LA 70087 USA
关键词
brachytherapy; iridium-192; radiation dosimetry; Monte Carlo; MCNP;
D O I
10.1118/1.2733809
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The MCNP5 Monte Carlo code was used to simulate the dosimetry of an M-19 iridium-192 high dose rate brachytherapy source in both air/vacuum and water environments with the in-air photon spectrum filtered to remove low-energy photons below delta= 10 keV. Dosimetric data was organized into an away-along table and was used to derive the updated AAPM Task Group Report No. 43 (TG-43U1) parameters including S-K, D(r, theta), Lambda, g(L)(r), F(r, theta), phi(an)(r), and (phi) over bar (an) and their respective statistical uncertainties. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1999 / 2006
页数:8
相关论文
共 50 条
  • [1] Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
    Gadhi, M. A.
    Buzdar, S. A.
    Afzal, M.
    Fatmi, Sh.
    Akhtar, M. S.
    Nizamani, A. H.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2013, 11 (03): : 189 - 193
  • [2] Determination of the tissue inhomogeneity correction in high dose rate Brachytherapy for Iridium-192 source
    Ravikumar, Barlanka
    Lakshminarayana, S.
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (01) : 27 - 31
  • [3] The Dose Distribution from Iridium-192 Source on Cervical Cancer Brachytherapy by Manchester System Using Monte Carlo Simulation
    Kurniati, F.
    Krisna, F. P.
    Junios, J.
    Haryanto, F.
    ATOM INDONESIA, 2021, 47 (03) : 205 - 211
  • [4] Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom
    Mowlavi, A. A.
    Cupardo, F.
    Severgnini, M.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2008, 6 (01): : 37 - 41
  • [5] Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Sarabiasl, Akbar
    Ayoobian, Navid
    Jabbari, Iraj
    Poorbaygi, Hossein
    Javanshir, Mohammad Reza
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (02) : 413 - 422
  • [6] Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Karaiskos, P
    Sandilos, P
    MEDICAL PHYSICS, 2000, 27 (11) : 2521 - 2527
  • [7] A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Sandilos, P
    Dardoufas, K
    Vlachos, L
    MEDICAL PHYSICS, 1999, 26 (08) : 1498 - 1502
  • [8] Monte Carlo dosimetry of a new 192Ir pulsed dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Pantelis, E
    Papagiannis, P
    Sakelliou, L
    Kouwenhoven, E
    Baltas, D
    MEDICAL PHYSICS, 2003, 30 (01) : 9 - 16
  • [9] Effect of inhomogeneities and source position on dose distribution of nucletron high dose rate Ir-192 brachytherapy source by Monte Carlo simulation
    Chandola, R. M.
    Tiwari, S.
    Kowar, M. K.
    Choudhary, V.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2010, 6 (01) : 54 - 57
  • [10] Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Sakelliou, L
    Sandilos, P
    Antypas, C
    Vlachos, L
    Koutsouveli, E