Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study

被引:61
作者
van Hamersvelt, Robbert W. [1 ]
Eijsvoogel, Nienke G. [2 ]
Mihl, Casper [2 ]
de Jong, Pim A. [1 ]
Schilham, Arnold M. R. [1 ]
Buls, Nico [3 ]
Das, Marco [2 ]
Leiner, Tim [1 ]
Willemink, Martin J. [1 ]
机构
[1] Univ Utrecht, Dept Radiol, Univ Med Ctr Utrecht, POB 85500, NL-3508 GA Utrecht, Netherlands
[2] Maastricht Univ, Dept Radiol, Med Ctr, Maastricht, Netherlands
[3] Vrije Univ Brussel, Radiol, UZ Brussel, Brussels, Belgium
关键词
Iodinated contrast media; Dual-energy CT; Thoracic aorta; Low kVp; Image quality; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; REDUCED IODINE LOAD; CORONARY-ANGIOGRAPHY; IMAGE-RECONSTRUCTION; CIRCULATION PHANTOM; ABDOMINAL CT; MEDIA; REDUCTION; ACCURACY; TRIAL;
D O I
10.1007/s10554-018-1329-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigated the feasibility and extent to which iodine concentration can be reduced in computed tomography angiography imaging of the aorta and coronary arteries using low tube voltage and virtual monochromatic imaging of 3 major dual-energy CT (DECT) vendors. A circulation phantom was imaged with dual source CT (DSCT), gemstone spectral imaging (GSI) and dual-layer spectral detector CT (SDCT). For each scanner, a reference scan was acquired at 120 kVp using routine iodine concentration (300 mg I/ml). Subsequently, scans were acquired at lowest possible tube potential (70, 80, 80 kVp, respectively), and DECT-mode (80/150Sn, 80/140 and 120 kVp, respectively) in arterial phase after administration of iodine (300, 240, 180, 120, 60, 30 mg I/ml). Objective image quality was evaluated using attenuation, CNR and dose corrected CNR (DCCNR) measured in the aorta and left main coronary artery. Average DCCNR at reference was 227.0, 39.7 and 60.2 for DSCT, GSI and SDCT. Maximum iodine concentration reduction without loss of DCCNR was feasible down to 180 mg I/ml (40% reduced) for DSCT (DCCNR 467.1) and GSI (DCCNR 46.1) using conventional CT low kVp, and 120 mg I/ml (60% reduced) for SDCT (DCCNR 171.5) using DECT mode. Low kVp scanning and DECT allows for 40-60% iodine reduction without loss in image quality compared to reference. Optimal scan protocol and to which extent varies per vendor. Further patient studies are needed to extend and translate our findings to clinical practice.
引用
收藏
页码:1265 / 1275
页数:11
相关论文
共 31 条
[1]   Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease [J].
Budoff, Matthew J. ;
Dowe, David ;
Jollis, James G. ;
Gitter, Michael ;
Sutherland, John ;
Halamert, Edward ;
Scherer, Markus ;
Bellinger, Raye ;
Martin, Arthur ;
Benton, Robert ;
Delago, Augustin ;
Min, James K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (21) :1724-1732
[2]   Contrast agent and radiation dose reduction in abdominal CT by a combination of low tube voltage and advanced image reconstruction algorithms [J].
Buls, Nico ;
Van Gompel, Gert ;
Van Cauteren, Toon ;
Nieboer, Koenraad ;
Willekens, Inneke ;
Verfaillie, Guy ;
Evans, Paul ;
Macholl, Sven ;
Newton, Ben ;
de Mey, Johan .
EUROPEAN RADIOLOGY, 2015, 25 (04) :1023-1031
[3]   Monochromatic image reconstruction by dual energy imaging allows half iodine load computed tomography coronary angiography [J].
Carrascosa, Patricia ;
Leipsic, Jonathon A. ;
Capunay, Carlos ;
Deviggiano, Alejandro ;
Vallejos, Javier ;
Goldsmit, Alejandro ;
Rodriguez-Granillo, Gaston A. .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (10) :1915-1920
[4]   Abdominal rapid-kVp-switching dual-energy MDCT with reduced IV contrast compared to conventional MDCT with standard weight-based IV contrast: an intra-patient comparison [J].
Clark, Zachary E. ;
Bolus, David N. ;
Little, Mark D. ;
Morgan, Desiree E. .
ABDOMINAL IMAGING, 2015, 40 (04) :852-858
[5]   New Applications of Cardiac Computed Tomography Dual-Energy, Spectral, and Molecular CT Imaging [J].
Danad, Ibrahim ;
Fayad, Zahi A. ;
Willemink, Martin J. ;
Min, James K. .
JACC-CARDIOVASCULAR IMAGING, 2015, 8 (06) :710-723
[6]   Spectral Optimization of Chest CT Angiography with Reduced Iodine Load: Experience in 80 Patients Evaluated with Dual-Source, Dual-Energy CT [J].
Delesalle, Marie-Aurelie ;
Pontana, Francois ;
Duhamel, Alain ;
Faivre, Jean-Baptiste ;
Flohr, Thomas ;
Tacelli, Nunzia ;
Remy, Jacques ;
Remy-Jardin, Martine .
RADIOLOGY, 2013, 267 (01) :256-266
[7]   Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media [J].
Grant, Katharine L. ;
Flohr, Thomas G. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Thomas, Christoph ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2014, 49 (09) :586-592
[8]   Low-Contrast and Low-Radiation Dose Protocol in Cardiac Computed Tomography: Usefulness of Low Tube Voltage and Knowledge-Based Iterative Model Reconstruction Algorithm [J].
Iyama, Yuji ;
Nakaura, Takeshi ;
Yokoyama, Koichi ;
Kidoh, Masafumi ;
Harada, Kazunori ;
Oda, Seitaro ;
Tokuyasu, Shinichi ;
Yamashita, Yasuyuki .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) :941-947
[9]  
Johnson TRC, 2011, MED RADIOL DIAGN IMA, P1, DOI 10.1007/978-3-642-01740-7
[10]   Image Fusion in Dual Energy Computed Tomography for Detection of Hypervascular Liver Hepatocellular Carcinoma Phantom and Preliminary Studies [J].
Kim, Kyung Su ;
Lee, Jeong Min ;
Kim, Seung Ho ;
Kim, Kyung Won ;
Kim, Soo Jin ;
Cho, Seung Hyun ;
Han, Joon Koo ;
Choi, Byung Ihn .
INVESTIGATIVE RADIOLOGY, 2010, 45 (03) :149-157