Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible

被引:0
作者
Cochran, DL
Schenk, RK
Lussi, A
Higginbottom, FL
Buser, D
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Periodont, San Antonio, TX 78284 USA
[2] Univ Bern, Dept Pathophysiol, CH-3012 Bern, Switzerland
[3] Univ Bern, Sch Dent Med, Dept Operat Dent, CH-3012 Bern, Switzerland
[4] Baylor Coll Dent, Dept Oral & Maxillofacial Surg & Pharmacol, Dallas, TX 75246 USA
[5] Univ Bern, Sch Dent Med, Dept Oral Surg, CH-3012 Bern, Switzerland
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1998年 / 40卷 / 01期
关键词
surface characteristics; titanium implants; osseointegration; bone response; loaded implants;
D O I
10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO;2-Q
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Many dental clinical implant studies have focused on the success of endosseous implants with a variety of surface characteristics. Most of the surface alterations have been aimed at achieving greater bone-to-implant contact as determined histometrically at the light microscopic level. A previous investigation in non-oral bone under shortterm healing periods (3 and 6 weeks) indicated that a sandblasted and acid-etched titanium (SLA) implant had a greater bone-to-implant contact than did a comparably-shaped implant with a titanium plasma-sprayed (TPS) surface. In this canine mandible study, nonsubmerged implants with a SLA surface were compared to TPS-coated implants under loaded and nonloaded conditions for up to 15 months. Six foxhound dogs had 69 implants placed in an alternating pattern with six implants placed bilaterally in each dog. Gold crowns that mimicked the natural occlusion were fabricated for four dogs. Histometric analysis of bone contact with the implants was made for two dogs after 3 months of healing (unloaded group), 6 months of healing (3 months loaded), and after 15 months of healing (12 months loaded). The SLA implants had a significantly higher (p < 0.001) percentage of bone-to-implant contact than did the TPS implants after 3 months of healing (72.33 +/- 7.16 versus 52.15 +/- 9.19; mean +/- SD). After 3 months of loading (6 months of healing) no significant difference was found between the SLA and TPS surfaced implants (68.21 +/- 10.44 and 78.18 +/- 6.81, respectively). After 12 months of loading (15 months of healing) the SLA implants had a significantly greater percentage (p < 0.001) of bone-to-implant contact than did the TPS implants (71.68 +/- 6.64 and 58.88 +/- 4.62, respectively). No qualitative differences in bone tissue were observed between the two groups of implants nor was there any difference between the implants at the clinical level. These results are consistent with earlier studies on SLA implants and suggest that this surface promotes greater osseous contact at earlier time points compared to TPS-coated implants. (C) 1998 John Wiley & Sons, Inc.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 28 条
[1]  
BEHNEKE A, 1992, Z ZAHNARZTLICHE IMPL, V8, P97
[2]  
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[3]  
BRANEMARK P I, 1969, Scandinavian Journal of Plastic and Reconstructive Surgery, V3, P81
[4]   Tissue integration of non-submerged implants 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants [J].
Buser, D. ;
Weber, H-P ;
Lang, N. P. .
CLINICAL ORAL IMPLANTS RESEARCH, 1990, 1 (01) :33-40
[5]  
Buser D, 1991, Int J Oral Maxillofac Implants, V6, P405
[6]   INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS [J].
BUSER, D ;
SCHENK, RK ;
STEINEMANN, S ;
FIORELLINI, JP ;
FOX, CH ;
STICH, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :889-902
[7]   Long-term evaluation of non-submerged ITI implants .1. 8-year life table analysis of a prospective multi-center study with 2359 implants [J].
Buser, D ;
MericskeStern, R ;
Bernard, JP ;
Behneke, A ;
Behneke, N ;
Hirt, HP ;
Belser, UC ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) :161-172
[8]  
Carlsson L, 1988, Int J Oral Maxillofac Implants, V3, P21
[9]   Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: Radiographic results [J].
Cochran, DL ;
Nummikoski, PV ;
Higginbottom, FL ;
Hermann, JS ;
Makins, SR ;
Buser, D .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) :240-252
[10]   Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible [J].
Cochran, DL ;
Hermann, JS ;
Schenk, RK ;
Higginbottom, FL ;
Buser, D .
JOURNAL OF PERIODONTOLOGY, 1997, 68 (02) :186-197