Preprocedural Albumin Levels and Risk of In-Stent Restenosis After Coronary Stenting With Bare-Metal Stent

被引:28
|
作者
Celik, Ibrahim Etem [1 ]
Yarlioglues, Mikail [1 ]
Kurtul, Alparslan [1 ]
Duran, Mustafa [1 ]
Koseoglu, Cemal [1 ]
Oksuz, Fatih [1 ]
Aksoy, Ozlem [1 ]
Murat, Sani Namik [1 ]
机构
[1] Ankara Educ & Res Hosp, Dept Cardiol, Ankara, Turkey
关键词
serum albumin level; in-stent restenosis; coronary artery disease; SERUM-ALBUMIN; ASSOCIATION; MORTALITY; INFLAMMATION; SURVIVAL; DISEASE; INJURY;
D O I
10.1177/0003319715598084
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
In-stent restenosis (ISR) remains a significant clinical problem in patients with coronary artery disease treated with percutaneous coronary intervention. Decreased serum albumin (SA) level is related to an increased risk of cardiovascular events. The aim of the present study was to assess whether SA levels at admission are an independent predictor of ISR in patients undergoing bare-metal stent (BMS) implantation. A total of 341 patients (aged 61 +/- 11, 65.4% men) with a history of BMS implantation and a further control coronary angiography due to stable angina pectoris (SAP) were included. The study population was classified into 2 groups: patients with and without ISR. The ISR was observed in 140 (41.1%) patients. We found significantly lower SA levels in patients who developed ISR than in those who did not (3.69 +/- 0.41 vs 4.07 +/- 0.35 mg/dL, P < .001). Multivariate analysis revealed that SA level (odds ratio 0.109, 95% confidence interval 0.017-0.700, P = .020), stent diameter, reason for stent implantation, and body mass index were independent risk factors for the development of ISR. The SA level at admission is inversely associated with ISR in patients with SAP.
引用
收藏
页码:478 / 483
页数:6
相关论文
共 50 条
  • [11] Long-Term Outcomes after Intracoronary β-irradiation for In-Stent Restenosis in Bare-Metal Stents
    Maeder, Micha T.
    Pfisterer, Matthias E.
    Buser, Peter T.
    Roser, Hans W.
    Roth, Jakob
    Weilenmann, Daniel
    Nietlispach, Fabian P.
    Zellweger, Michael J.
    Amsler, Beat
    Kaiser, Christoph A.
    JOURNAL OF INVASIVE CARDIOLOGY, 2008, 20 (04) : 179 - 184
  • [12] Clinical Outcomes of Drug-Eluting Versus Bare-Metal In-Stent Restenosis
    Singh, Inder M.
    Filby, Steven J.
    El Sakr, Fredy
    Gorodeski, Eiran Z.
    Lincoff, A. Michael
    Ellis, Stephen G.
    Shishehbor, Mehdi H.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (03) : 338 - 342
  • [13] Effect of shuxinyin on in-stent restenosis after coronary artery stenting
    Xian Wang
    Zhong-xiang Lin
    Jun-bo Ge
    Xu Liu
    Yan He
    Zhen-xian Zhang
    lin Shen
    Chinese Journal of Integrated Traditional and Western Medicine, 2002, 8 (3): : 167 - 171
  • [14] An increase of interleukin-33 serum levels after coronary stent implantation is associated with coronary in-stent restenosis
    Demyanets, Svitlana
    Tentzeris, Ioannis
    Jarai, Rudolf
    Katsaros, Katharina M.
    Farhan, Serdar
    Wonnerth, Anna
    Weiss, Thomas W.
    Wojta, Johann
    Speidl, Walter S.
    Huber, Kurt
    CYTOKINE, 2014, 67 (02) : 65 - 70
  • [15] Bare metal stent implantation for in-stent restenosis with a drug-eluting stent
    Matsuoka, Hiroshi
    Kawakami, Hideo
    Ohshita, Akira
    Kohno, Tamami
    Shigemi, Susumu
    Okayama, Hideki
    Higaki, Jitsuo
    JOURNAL OF CARDIOLOGY, 2010, 55 (01) : 135 - 138
  • [16] Preventable effects of bare-metal stent on restenosis after everolimus-eluting stent deployment
    Shirakabe, Akihiro
    Takano, Masamichi
    Yamamoto, Masanori
    Kurihara, Osamu
    Kobayashi, Nobuaki
    Matsushita, Masato
    Tsurumi, Masafumi
    Okazaki, Hirotake
    Hata, Noritake
    Shimizu, Wataru
    HEART AND VESSELS, 2016, 31 (03) : 434 - 437
  • [17] Preventable effects of bare-metal stent on restenosis after everolimus-eluting stent deployment
    Akihiro Shirakabe
    Masamichi Takano
    Masanori Yamamoto
    Osamu Kurihara
    Nobuaki Kobayashi
    Masato Matsushita
    Masafumi Tsurumi
    Hirotake Okazaki
    Noritake Hata
    Wataru Shimizu
    Heart and Vessels, 2016, 31 : 434 - 437
  • [18] Sirolimus-eluting stent implantation for bare-metal in-stent restenosis:: is there any evidence for a late catch-up phenomenon?
    Sheiban, Imad
    Chiribiri, Amedeo
    Galli, Stefano
    Biondi-Zoccai, Giuseppe
    Montorsi, Piero
    Beninati, Serena
    Fabbiocchi, Franco
    Moretti, Claudio
    Omede, Pierluigi
    Trabattoni, Daniela
    Lotrionte, Marzia
    Trevi, Gian Paolo
    Bartorelli, Antonio L.
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2008, 9 (08) : 783 - 788
  • [19] Usefulness of the platelet-to-lymphocyte ratio in predicting bare-metal stent restenosis
    Yilmaz, Samet
    Sen, Fatih
    Unal, Sefa
    Yayla, Cagri
    Ozeke, Ozcan
    Aras, Dursun
    Topaloglu, Serkan
    Aydogdu, Sinan
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2015, 49 (01) : 39 - 44
  • [20] The association of preprocedural C-reactive protein/albumin ratio with in-stent restenosis in patients undergoing iliac artery stenting
    Calik, Ali Nazmi
    Inan, Duygu
    Karatas, Mehmet Baran
    Akdeniz, Evliya
    Gen, Duygu
    Canga, Yigit
    Cinar, Tufan
    Emre, Ayse
    JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, 2020, 12 (03) : 179 - 184