The effect of tibial insert design on rising from a chair;: motion analysis after total knee replacement

被引:18
作者
Saari, T [1 ]
Tranberg, R
Zügner, R
Uvehammer, J
Kärrholm, J
机构
[1] Sahlgrens Univ Hosp, Dept Orthopaed, S-41345 Gothenburg, Sweden
[2] Univ Gothenburg, S-41345 Gothenburg, Sweden
[3] Lundberg Lab Mot Anal, S-41267 Gothenburg, Sweden
关键词
motion analysis; total knee arthroplasty; sit-to-stand movement; polyethylene tibial insert; posterior cruciate retention; posterior cruciate resection;
D O I
10.1016/j.clinbiomech.2004.06.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. There are few previous studies of sit-to-stand movement following total knee arthroplasty. Aim of the study was to test the hypotheses that total knee replacement alters the maximum trunk, hip, knee and ankle flexion-extension movements during chair rising, and that the design of the tibial plateau has small influence on the kinematics. Methods. A motion analysis system was used to evaluate kinematics of the trunk, hip, knee and ankle when rising from one chair and sitting down on another. Patients with 5degrees varus/valgus alignment or less received either a flat or a concave tibial insert with retention of the posterior cruciate ligament. Patients who had more malalignment and/or extension defect of 10 or more were randomized to receive the concave or a posterior-stabilized tibial component with resection of the posterior cruciate ligament. The two groups of patients operated with and without resection of the posterior cruciate ligament were analysed separately and compared with a control group. 28 patients (29 knees) and 16 controls were in the final analysis. Findings. Decreased hip and knee extension compared to the controls was seen, but there were no statistically significant differences in kinematics between the designs. Interpretation. Choice of implant design in total knee arthroplasty had no detectable effects on kinematics of hip and knee joints during sit-to-stand movement. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:951 / 956
页数:6
相关论文
共 21 条
[1]  
[Anonymous], 1991, PHYSIOTHERAPY, DOI DOI 10.1016/S0031-9406(10)61866-4
[3]  
DENNIS DA, 1998, CLIN ORTHOP RELAT R, V356, P7
[4]   Quantitative gait analysis after bilateral total knee arthroplasty with two different systems within each subject [J].
deQuervain, IAK ;
Stussi, E ;
Muller, R ;
Drobny, T ;
Munzinger, U ;
Gschwend, N .
JOURNAL OF ARTHROPLASTY, 1997, 12 (02) :168-179
[5]  
DORR LD, 1988, CLIN ORTHOP RELAT R, V236, P36
[6]  
Ellis M. I., 1979, Engineering in Medicine, V8, P33, DOI 10.1243/EMED_JOUR_1979_008_009_02
[7]   FORCES IN THE KNEE-JOINT WHILE RISING FROM A SEATED POSITION [J].
ELLIS, MI ;
SEEDHOM, BB ;
WRIGHT, V .
JOURNAL OF BIOMEDICAL ENGINEERING, 1984, 6 (02) :113-120
[8]  
HAGSTEDT B, 1980, ACTA ORTHOP SCAND, V51, P963, DOI 10.3109/17453678008990901
[9]   CONTACT PRESSURES FROM AN INSTRUMENTED HIP ENDOPROSTHESIS [J].
HODGE, WA ;
CARLSON, KL ;
FIJAN, RS ;
BURGESS, RG ;
RILEY, PO ;
HARRIS, WH ;
MANN, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (09) :1378-1386
[10]   AN INVESTIGATION INTO THE PROBLEMS OF EASY CHAIRS USED BY THE ARTHRITIC AND THE ELDERLY [J].
MUNTON, JS ;
ELLIS, MI ;
CHAMBERLAIN, MA ;
WRIGHT, V .
RHEUMATOLOGY AND REHABILITATION, 1981, 20 (03) :164-173