Thermal Neutron SRAM Detector Characterization at the CERN Mixed-Field Facility, CHARM

被引:1
作者
Cangialosi, C. [1 ]
Danzeca, S. [1 ]
Brucoli, M. [1 ]
Brugger, M. [1 ]
Masi, A. [1 ]
机构
[1] CERN, European Org Nucl Res, CH-1211 Geneva, Switzerland
关键词
CERN High AcceleRator Mixed-field facility (CHARM); cross section; hadron; Large Hadron Collider (LHC); mixed field; protons; radiation; radiation monitoring system (RadMon); reliability; single event upset (SEU); static random access memory (SRAM); thermal neutrons; LHC;
D O I
10.1109/TNS.2018.2829631
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The radiation spectra in the CERN Large Hadron Collider (LHC) ranges from gigaelectronvolts down to thermal neutron levels. It is known that the thermal neutrons can significantly affect the electronic devices and systems exposed to the radiation environment of the tunnel and the shielded areas of the LHC. CERN's radiation monitoring (RadMon) system uses static random access memories (SRAMs) to measure the contributions to the spectrum from both the high-energy hadrons (>20 MeV) and thermal neutrons. The knowledge of the SRAM thermal neutron cross section is required for evaluating their contribution to the particle spectra and thus identifying the thermal neutron critical area. This paper describes a procedure to acquire, by means of RadMon system, the thermal neutron cross section of SRAM memories in a mixed-field environment. The capabilities of the CERN High AcceleRator Mixed-field facility (CHARM) to measure the thermal neutron sensitivity are then investigated. The procedure is evaluated by comparing the thermal neutron cross sections obtained at CHARM and the one measured using a pure thermal neutron beam. The same procedure could be applied to other devices to understand their susceptibility.
引用
收藏
页码:1887 / 1893
页数:7
相关论文
共 11 条
  • [1] [Anonymous], 2017, PROTON IRRADIATION F
  • [2] Radiation-induced soft errors in advanced semiconductor technologies
    Baumann, RC
    [J]. IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, 2005, 5 (03) : 305 - 316
  • [3] Beaucour J., 2015, 2015 15th European Conference on Radiation and its Effects on Components and Systems (RADECS), DOI 10.1109/RADECS.2015.7365616
  • [4] CERN, 2017, CHARM WEBS
  • [5] Qualification and Characterization of SRAM Memories Used as Radiation Sensors in the LHC
    Danzeca, S.
    Spiezia, G.
    Brugger, M.
    Dusseau, L.
    Foucard, G.
    Alia, R. Garcia
    Mala, P.
    Masi, A.
    Peronnard, P.
    Soltes, J.
    Thornton, A.
    Viererbl, L.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (06) : 3458 - 3465
  • [6] Danzeca S., 2014, THESIS
  • [7] LHC RadMon SRAM Detectors Used at Different Voltages to Determine the Thermal Neutron to High Energy Hadron Fluence Ratio
    Kramer, D.
    Brugger, M.
    Klupak, V.
    Pignard, C.
    Roeed, K.
    Spiezia, G.
    Viererbl, L.
    Wijnands, T.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 1117 - 1122
  • [8] CHARM: A Mixed Field Facility at CERN for Radiation Tests in Ground, Atmospheric, Space and Accelerator Representative Environments
    Mekki, J.
    Brugger, M.
    Alia, R. G.
    Thornton, A.
    Mota, N. C. Dos Santos
    Danzeca, S.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (04) : 2106 - 2114
  • [9] FLUKA Simulations for SEE Studies of Critical LHC Underground Areas
    Roed, Ketil
    Boccone, Vittorio
    Brugger, Markus
    Ferrari, Alfredo
    Kramer, Daniel
    Lebbos, Elias
    Losito, Roberto
    Mereghetti, Alessio
    Spiezia, Giovanni
    Versaci, Roberto
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 932 - 938
  • [10] Roeed K., 2011, TECH REP