Immediate and Long-Term Echocardiographic Findings after Transcatheter Aortic Valve Implantation for the Treatment of Aortic Stenosis: The Cribier-Edwards/Edwards-Sapien Valve Experience

被引:36
|
作者
Bauer, Fabrice [1 ,2 ]
Lemercier, Mathieu [1 ]
Zajarias, Alan
Tron, Christophe
Eltchaninoff, Helene
Cribier, Alain [1 ,2 ]
机构
[1] Rouen Univ Hosp, Div Cardiol, Rouen, France
[2] INSERM, U644, Rouen Med Sch, Res Lab, Rouen, France
关键词
Aortic stenosis; Doppler; Prosthesis; Surgery; Transcatheter heart valve implantation; PERCUTANEOUS BALLOON VALVULOPLASTY; PROSTHETIC HEART-VALVE; FOLLOW-UP; REPLACEMENT; REGURGITATION; IMPROVEMENT; IMPACT;
D O I
10.1016/j.echo.2010.01.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The role of transcatheter aortic valve implantation in the treatment of calcific aortic stenosis is evolving. Immediate and long-term echocardiographic findings are poorly reported. Methods: Eighty-eight patients in whom surgical aortic valve replacement was contraindicated were studied before and 1 and 7 days, 1 month, and 1 and 2 years after the transcatheter procedure by echocardiography for hemodynamic. Transaortic pressure gradient, permeability index, and aortic valve area were measured, and aortic regurgitation was estimated from a multiparametric approach. A subset group of 36 patients (23-mm valve, n = 18; 26-mm valve, n = 18) with optimal ultrasound window were investigated for valve geometry at 7 days. We measured the sphericity index (anteroposterior to sagittal diameter ratio) and the angulation of the prosthesis with the ascending aorta. Results: By analysis of variance, transaortic pressure gradient significantly decreased and aortic valve area increased after the procedure (P < .0001 and P < .0001 respectively). Aortic regurgitation severity tended to decline at follow-up (P = .20) and was unaffected by valve size (P = .35). Leaks were paraprosthetic in 77% of cases, intraprosthetic in 6% of cases, and both in 17% of cases. Overall, the sphericity index was 1.03 +/- 0.07 and the angulation was 2.9 +/- 1.1 degrees. Conclusion: Echocardiography aids in the demonstration of appropriate prosthesis function and positioning after transcatheter aortic valve implantation. (J Am Soc Echocardiogr 2010;23:370-6.)
引用
收藏
页码:370 / 376
页数:7
相关论文
共 50 条
  • [21] Ventricular Embolization of Edwards SAPIEN Prosthesis Following Transcatheter Aortic Valve Implantation
    Gul, Mehmet
    Erkanli, Korhan
    Erol, Mustafa Kemal
    Bakir, Ihsan
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (10) : 537 - 538
  • [22] Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access
    Greif, Martin
    Lange, Philipp
    Mair, Helmut
    Becker, Christoph
    Schmitz, Christoph
    Steinbeck, Gerhard
    Kupatt, Christian
    CLINICAL RESEARCH IN CARDIOLOGY, 2012, 101 (12) : 993 - 1001
  • [23] Periprocedural and Short-Term Outcomes of Transfemoral Transcatheter Aortic Valve Implantation With the Sapien XT as Compared With the Edwards Sapien Valve
    Mussardo, Marco
    Latib, Azeem
    Chieffo, Alaide
    Godino, Cosmo
    Ielasi, Alfonso
    Cioni, Micaela
    Takagi, Kensuke
    Davidavicius, Giedrius
    Montorfano, Matteo
    Maisano, Francesco
    Carlino, Mauro
    Franco, Annalisa
    Covello, Remo D.
    Spagnolo, Pietro
    Grimaldi, Antonio
    Alfieri, Ottavio
    Colombo, Antonio
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (07) : 743 - 750
  • [24] Transcatheter Aortic Valve Implantation Experience with SAPIEN 3
    Ohno, Y.
    Tamburino, C.
    Barbanti, M.
    MINERVA CARDIOANGIOLOGICA, 2015, 63 (03): : 205 - 216
  • [25] Transcatheter Aortic and Mitral Valve-in-Valve Implantation Using the Edwards Sapien 3 Heart Valve
    Shivaraju, Anupama
    Michel, Jonathan
    Frangieh, Antonio H.
    Ott, Ilka
    Thilo, Christian
    Schunkert, Heribert
    Kastrati, Adnan
    Leon, Martin B.
    Dvir, Danny
    Kodali, Susheel
    Bapat, Vinayak
    Guerrero, Mayra
    Kasel, Albert M.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (14):
  • [26] Evaluation of Multislice Computed Tomography Early After Transcatheter Aortic Valve Implantation With the Edwards SAPIEN Bioprosthesis
    Caudron, Jerome
    Fares, Jeannette
    Hauville, Camille
    Cribier, Alain
    Dacher, Jean-Nicolas
    Tron, Christophe
    Bauer, Fabrice
    Litzler, Pierre-Yves
    Bessou, Jean-Paul
    Eltchaninoff, Helene
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (06) : 873 - 881
  • [27] Transfemoral aortic valve implantation is more successful with the Edwards Sapien 3 compared with the Edwards XT for the treatment of symptomatic severe aortic stenosis
    Gonska, Birgid
    Seeger, Julia
    Junker, Alexander
    Rodewald, Christoph
    Trepte, Ulrike
    Scharnbeck, Dominik
    Rottbauer, Wolfgang
    Woehrle, Jochen
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2018, 111 (8-9) : 470 - 479
  • [28] Comparison of Edwards SAPIEN 3 versus SAPIEN XT in transfemoral transcatheter aortic valve implantation: Difference of valve selection in the real world
    Arai, Takahide
    Lefevre, Thierry
    Hovasse, Thomas
    Morice, Marie-Claude
    Garot, Philippe
    Benamer, Hakim
    Unterseeh, Thierry
    Hayashida, Kentaro
    Watanabe, Yusuke
    Bouvier, Erik
    Cormier, Bertrand
    Chevalier, Bernard
    JOURNAL OF CARDIOLOGY, 2017, 69 (3-4) : 565 - 569
  • [29] Transfemoral Aortic Valve Implantation with the New Edwards Sapien 3 Valve for Treatment of Severe Aortic Stenosis-Impact of Valve Size in a Single Center Experience
    Woehrle, Jochen
    Gonska, Birgid
    Rodewald, Christoph
    Seeger, Julia
    Scharnbeck, Dominik
    Rottbauer, Wolfgang
    PLOS ONE, 2016, 11 (03):
  • [30] Long-term Follow-up After Transcatheter Aortic Valve Implantation for Severe Aortic Stenosis
    Salinas, Pablo
    Moreno, Raul
    Calvo, Luis
    Sanchez-Recalde, Angel
    Jimenez-Valero, Santiago
    Galeote, Guillermo
    Lopez-Fernandez, Teresa
    Ramirez, Ulises
    Riera, Luis
    Plaza, Ignacio
    Moreno, Isidro
    Maria Mesa, Jose
    Luis Lopez-Sendon, Jose
    REVISTA ESPANOLA DE CARDIOLOGIA, 2016, 69 (01): : 37 - 44