Immediate and Long-Term Echocardiographic Findings after Transcatheter Aortic Valve Implantation for the Treatment of Aortic Stenosis: The Cribier-Edwards/Edwards-Sapien Valve Experience

被引:36
|
作者
Bauer, Fabrice [1 ,2 ]
Lemercier, Mathieu [1 ]
Zajarias, Alan
Tron, Christophe
Eltchaninoff, Helene
Cribier, Alain [1 ,2 ]
机构
[1] Rouen Univ Hosp, Div Cardiol, Rouen, France
[2] INSERM, U644, Rouen Med Sch, Res Lab, Rouen, France
关键词
Aortic stenosis; Doppler; Prosthesis; Surgery; Transcatheter heart valve implantation; PERCUTANEOUS BALLOON VALVULOPLASTY; PROSTHETIC HEART-VALVE; FOLLOW-UP; REPLACEMENT; REGURGITATION; IMPROVEMENT; IMPACT;
D O I
10.1016/j.echo.2010.01.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The role of transcatheter aortic valve implantation in the treatment of calcific aortic stenosis is evolving. Immediate and long-term echocardiographic findings are poorly reported. Methods: Eighty-eight patients in whom surgical aortic valve replacement was contraindicated were studied before and 1 and 7 days, 1 month, and 1 and 2 years after the transcatheter procedure by echocardiography for hemodynamic. Transaortic pressure gradient, permeability index, and aortic valve area were measured, and aortic regurgitation was estimated from a multiparametric approach. A subset group of 36 patients (23-mm valve, n = 18; 26-mm valve, n = 18) with optimal ultrasound window were investigated for valve geometry at 7 days. We measured the sphericity index (anteroposterior to sagittal diameter ratio) and the angulation of the prosthesis with the ascending aorta. Results: By analysis of variance, transaortic pressure gradient significantly decreased and aortic valve area increased after the procedure (P < .0001 and P < .0001 respectively). Aortic regurgitation severity tended to decline at follow-up (P = .20) and was unaffected by valve size (P = .35). Leaks were paraprosthetic in 77% of cases, intraprosthetic in 6% of cases, and both in 17% of cases. Overall, the sphericity index was 1.03 +/- 0.07 and the angulation was 2.9 +/- 1.1 degrees. Conclusion: Echocardiography aids in the demonstration of appropriate prosthesis function and positioning after transcatheter aortic valve implantation. (J Am Soc Echocardiogr 2010;23:370-6.)
引用
收藏
页码:370 / 376
页数:7
相关论文
共 50 条
  • [1] Evaluation of the Edwards SAPIEN 3 Transcatheter Valve For Aortic Stenosis
    Htun, Nay M.
    Webb, John G.
    EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (03) : 225 - 232
  • [2] Technique of Transcatheter Aortic Valve Implantation with the Edwards-Sapien® Heart Valve Using the Transfemoral Approach
    Cribier, Alain
    Litzler, Pierre-Yves
    Eltchaninoff, Helene
    Godin, Matthieu
    Tron, Christophe
    Bauer, Fabrice
    Bessou, Jean-Paul
    HERZ, 2009, 34 (05) : 347 - 356
  • [3] Single center experience with transcatheter aortic valve implantation using the Edwards SAPIEN™ Valve
    Nielsen, Hans Henrik Moller
    Thuesen, Leif
    Egeblad, Henrik
    Poulsen, Steen Hvitfeldt
    Klaaborg, Kaj-Erik
    Jakobsen, Carl-Johan
    Andersen, Henning Rud
    Hjortdal, Vibeke Elisabeth
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2011, 45 (05) : 261 - 266
  • [4] Outcomes After Transcatheter Aortic Valve Implantation With Both Edwards-SAPIEN and CoreValve Devices in a Single Center
    Godino, Cosmo
    Maisano, Francesco
    Montorfano, Matteo
    Latib, Azeem
    Chieffo, Alaide
    Michev, Iassen
    Al-Lamee, Rasha
    Bande, Marta
    Mussardo, Marco
    Arioli, Francesco
    Ielasi, Alfonso
    Cioni, Micaela
    Taramasso, Maurizio
    Arendar, Irina
    Grimaldi, Antonio
    Spagnolo, Pietro
    Zangrillo, Alberto
    La Canna, Giovanni
    Alfieri, Ottavio
    Colombo, Antonio
    JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) : 1110 - 1121
  • [5] Transaortic Transcatheter Aortic Valve Implantation Using Edwards SAPIEN Valve: A Novel Approach
    Bapat, Vinayak
    Khawaja, Muhammed Z.
    Attia, Rizwan
    Narayana, Ashok
    Wilson, Karen
    Macgillivray, Kirsty
    Young, Christopher
    Hancock, Jane
    Redwood, Simon
    Thomas, Martyn
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (05) : 733 - 740
  • [6] Transapical-transcatheter aortic valve implantation using the Edwards SAPIEN 3 valve
    Useini, Dritan
    Schlomicher, Markus
    Beluli, Blerta
    Christ, Hildegard
    Ewais, Elias
    Haldenwang, Peter
    Patsalis, Polykarpos
    Moustafine, Vadim
    Bechtel, Matthias
    Strauch, Justus
    JOURNAL OF CARDIOVASCULAR SURGERY, 2021, 62 (06) : 609 - 617
  • [7] The feasibility of transcatheter aortic valve implantation using the Edwards SAPIEN 3 for patients with severe bicuspid aortic stenosis
    Arai, Takahide
    Lefevre, Thierry
    Hovasse, Thomas
    Morice, Marie-Claude
    Romano, Mauro
    Benamer, Hakim
    Garot, Philippe
    Hayashida, Kentaro
    Bouvier, Erik
    Chevalier, Bernard
    JOURNAL OF CARDIOLOGY, 2017, 70 (3-4) : 220 - 224
  • [8] Emergency transfemoral aortic valve-in-valve implantation with the balloon-expandable Edwards-Sapien valve
    Taramasso, Maurizio
    Maisano, Francesco
    Michev, Iassen
    Dorigo, Enrica
    Denti, Paolo
    Covello, Remo Daniel
    Zangrillo, Alberto
    Alfieri, Ottavio
    Colombo, Antonio
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2009, 10 (12) : 936 - 939
  • [9] Short-and long-term need for permanent pacemaker after transcatheter implantation of the Edwards Sapien aortic valve prosthesis
    Moreno, Raul
    Calvo, Luis
    Sanchez-Recalde, Angel
    Galeote, Guillermo
    Jimenez-Valero, Santiago
    Lopez, Teresa
    Plaza, Ignacio
    Gonzalez-Davia, Rosa
    Ramirez, Ulises
    Maria Mesa, Jose
    Moreno-Gomez, Isidro
    Lopez-Sendon, Jose-Luis
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2015, 34 (11) : 665 - 672
  • [10] Edwards SAPIEN™ and Edwards SAPIEN XT™ transcatheter heart valves for the treatment of severe aortic stenosis
    Freeman, Melanie
    Webb, John G.
    EXPERT REVIEW OF MEDICAL DEVICES, 2012, 9 (06) : 563 - 569