Assessment of three-dimensional setup errors in image-guided pelvic radiotherapy for uterine and cervical cancer using kilovoltage cone-beam computed tomography and its effect on planning target volume margins

被引:39
作者
Patni, Nidhi [1 ]
Burela, Nagarjuna [1 ]
Pasricha, Rajesh [2 ]
Goyal, Jaishree [1 ]
Soni, Tej Prakash [1 ]
Kumar, T. Senthil [1 ]
Natarajan, T. [1 ]
机构
[1] Bhagwan Mahaveer Canc Hosp & Res Ctr, Dept Radiat Oncol, JLN Marg, Jaipur, Rajasthan, India
[2] GBH Amer Hosp, Dept Radiat Oncol, Udaipur, Rajasthan, India
关键词
Gynecological malignancy; image guidance; kilovoltage cone-beam computed tomography; margins; setup errors; INTERFRACTIONAL VARIATION; PATIENT SETUP; UP ERRORS; UNCERTAINTIES; ACCURACY; POSITION; IMPACT; TUMOR;
D O I
10.4103/0973-1482.199451
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To achieve the best possible therapeutic ratio using high-precision techniques (image-guided radiation therapy/volumetric modulated arc therapy [IGRT/VMAT]) of external beam radiation therapy in cases of carcinoma cervix using kilovoltage cone-beam computed tomography (kV-CBCT). Materials and Methods: One hundred and five patients of gynecological malignancies who were treated with IGRT (IGRT/VMAT) were included in the study. CBCT was done once a week for intensity-modulated radiation therapy and daily in IGRT/VMAT. These images were registered with the planning CT scan images and translational errors were applied and recorded. In all, 2078 CBCT images were studied. The margins of planning target volume were calculated from the variations in the setup. Results: The setup variation was 5.8, 10.3, and 5.6 mm in anteroposterior, superoinferior, and mediolateral direction. This allowed adequate dose delivery to the clinical target volume and the sparing of organ at risks. Conclusion: Daily kV-CBCT is a satisfactory method of accurate patient positioning in treating gynecological cancers with high-precision techniques. This resulted in avoiding geographic miss.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 20 条
  • [11] Estimation of setup uncertainty using planar and MVCT imaging for gynecologic malignancies
    Santanam, Lakshmi
    Esthappan, Jacqueline
    Mutic, Sasa
    Klein, Eric E.
    Goddu, S. Murty
    Chaudhari, Summer
    Wahab, Sasha
    El Naqa, Issam M.
    Low, Daniel A.
    Grigsby, Perry W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (05): : 1511 - 1517
  • [12] Optimizing image guidance frequency and implications on margins for gynecologic malignancies
    Stromberger, Carmen
    Gruen, Arne
    Wlodarczyk, Waldemar
    Budach, Volker
    Koehler, Christhardt
    Marnitz, Simone
    [J]. RADIATION ONCOLOGY, 2013, 8
  • [13] On-line set-up corrections during radiotherapy of patients with gynecologic tumors
    Stroom, JC
    Olofsen-van Acht, MJJ
    Quint, S
    Seven, M
    De Hoog, M
    Creutzberg, CL
    De Boer, HCJ
    Visser, AG
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (02): : 499 - 506
  • [14] Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report
    Stroom, JC
    Heijmen, BJM
    [J]. RADIOTHERAPY AND ONCOLOGY, 2002, 64 (01) : 75 - 83
  • [15] Conventional, conformal, and intensity-modulated radiation therapy treatment planning of external beam radiotherapy for cervical cancer:: The impact of tumor regression
    van de Bunt, L
    van der Heide, UA
    Ketelaars, M
    de Kort, GAP
    Jürgenliemk-Schulz, IM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (01): : 189 - 196
  • [16] The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    van Herk, M
    Remeijer, P
    Rasch, C
    Lebesque, JV
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04): : 1121 - 1135
  • [17] Errors and margins in radiotherapy
    van Herk, M
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) : 52 - 64
  • [18] Inclusion of geometric uncertainties in treatment plan evaluation
    van Herk, M
    Remeijer, P
    Lebesque, JV
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (05): : 1407 - 1422
  • [19] Interfractional and intrafractional accuracy during radiotherapy of gynecologic carcinomas: A comprehensive evaluation using the exactrac system
    Weiss, E
    Vorwerk, H
    Richter, S
    Hess, CF
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 69 - 79
  • [20] Positioning accuracy during VMAT of gynecologic malignancies and the resulting dosimetric impact by a 6-degree-of-freedom couch in combination with daily kilovoltage cone beam computed tomography
    Yao, Lihong
    Zhu, Lihong
    Wang, Junjie
    Liu, Lu
    Zhou, Shun
    Jiang, ShuKun
    Cao, Qianqian
    Qu, Ang
    Tian, Suqing
    [J]. RADIATION ONCOLOGY, 2015, 10