EFFECT OF METAL SELECTION AND PORCELAIN FIRING ON THE MARGINAL ACCURACY OF TITANIUM-BASED METAL CERAMIC RESTORATIONS

被引:38
作者
Shokry, Tamer E. [1 ]
Attia, Mazen
Mosleh, Ihab [2 ]
Elhosary, Mohamed [1 ]
Hamza, Tamer [1 ]
Shen, Chiayi [3 ]
机构
[1] Al Azhar Univ, Fac Med Dent, Dept Fixed Prosthodont, Cairo, Egypt
[2] Cairo Univ, Fac Oral & Dent Med, Dept Fixed Prosthodont, Cairo, Egypt
[3] Univ Florida, Dept Prosthodont, Gainesville, FL USA
关键词
COMMERCIALLY PURE TITANIUM; FIT; TEMPERATURE; ADAPTATION; DISTORTION; STRESS; CROWNS; ALLOY; CAST;
D O I
10.1016/S0022-3913(09)60216-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Titanium is the most biocompatible metal used For dental casting; however, there is concern about its marginal accuracy after porcelain application since this aspect has direct influence on marginal fit. Purpose. The purpose of this study was to determine the effect that metal selection and the porcelain firing procedure have on the marginal accuracy of metal ceramic prostheses. Material and methods. Cast CPTI, milled CP Ti, cast Ti-6Al-7Nb, and cast Ni-Cr copings (n=5) were fired with compatible porcelains (Triceram for titanium-based metals and VITA VMK 95 for Ni-Cr alloy). The Ni-Cr alloy fired with its porcelain served as the control. Photographs of metal copings placed on a master die were made. Marginal discrepancy was determined on the photographs using an image processing program at 8 predetermined locations before airborne-particle abrasion for porcelain application, after firing of the opaque layer, and after firing of the dentin layer. Repeated-measures 2-way ANOVA was used to investigate the effect of metal selection and firing stage, and paired t tests were used to determine the effect of each firing stage within each material group (alpha=.05). Results. ANOVA showed that both metal selection and firing stage significantly influenced the measured marginal discrepancy (P<.001), and there was interaction between the 2 variables (P<.001). Student-Newman-Keuls multiple comparison tests showed that there were significant differences between any 2 metals compared, at each stage of measurement. Paired t tests showed that significant changes in marginal discrepancy occurred with opaque Firing on milled CP Ti (P=.017) and cast Ti-6Al-7Nb alloy (P=.003). Conclusions. Titanium copings fabricated by CAD/CAM demonstrated the least marginal discrepancy among all groups, while the base metal (Ni-Cr) groups exhibited the most discrepancy of all groups tested. (J Prosthet Dent 2010;103:45-52)
引用
收藏
页码:45 / 52
页数:8
相关论文
共 24 条
[1]  
ADA Council Sci Affairs, 2003, J AM DENT ASSOC, V134, P347
[2]   EFFECT OF INCOMPATIBILITY STRESS ON THE FIT OF METAL-CERAMIC CROWNS [J].
ANUSAVICE, KJ ;
CARROLL, JE .
JOURNAL OF DENTAL RESEARCH, 1987, 66 (08) :1341-1345
[3]   MARGINAL ADAPTATION OF PORCELAIN MARGINS IN CERAMOMETAL RESTORATIONS [J].
ARNOLD, HN ;
AQUILINO, SA .
JOURNAL OF PROSTHETIC DENTISTRY, 1988, 59 (04) :409-417
[4]  
Besimo C, 1997, INT J PROSTHODONT, V10, P541
[5]   Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining [J].
Contreras, EFR ;
Henriques, GEP ;
Giolo, SR ;
Nobilo, MAA .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 88 (05) :467-472
[6]   THE EFFECT OF REPEATED FIRINGS ON THE MARGINS OF NONPRECIOUS CERAMOMETALS [J].
DEDERICH, DN ;
SVARE, CW ;
PETERSON, LC ;
TURNER, KA .
JOURNAL OF PROSTHETIC DENTISTRY, 1984, 51 (05) :628-630
[7]   EFFECT OF METAL DESIGN ON MARGINAL DISTORTION OF METAL-CERAMIC CROWNS [J].
DEHOFF, PH ;
ANUSAVICE, KJ .
JOURNAL OF DENTAL RESEARCH, 1984, 63 (11) :1327-1331
[8]   Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings [J].
Fonseca, JC ;
Henriques, GEP ;
Sobrinho, LC ;
de Góes, MF .
DENTAL MATERIALS, 2003, 19 (07) :686-691
[9]   The effect of mold temperature on castability of CPTi and Ti-6Al-4V castings into phosphate bonded investment materials [J].
Garcia Oliveira, Pedro Cesar ;
Adabo, Gelson Luis ;
Ribeiro, Ricardo Faria ;
Rocha, Sicknan Soares .
DENTAL MATERIALS, 2006, 22 (12) :1098-1102
[10]   Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al4V alloy after different polishing protocols [J].
Guilherme, AS ;
Henriques, GEP ;
Zavanelli, RA ;
Mesquita, MF .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (04) :378-385