Ultrasound-guided angioplasty in the treatment of arterio-venous fistula stenosis

被引:0
作者
Mateos Torres, Eduardo [1 ,2 ]
Mellado Joan, Meritxell [1 ,2 ]
Calsina Juscafresa, Laura [1 ]
Ruiz Carmona, Carlos [1 ,2 ]
Clara Velasco, Albert [1 ,2 ]
机构
[1] Hosp Mar, Inst Hosp Mar Invest Med IMIM, Serv Angiol & Cirugia Vasc, Barcelona, Spain
[2] Univ Autonoma Barcelona, Barcelona, Spain
来源
ANGIOLOGIA | 2019年 / 71卷 / 05期
关键词
Surgical arteriovenous shunt; Renal dialysis; Ultrasonography Doppler; Angioplasty; ENDOVASCULAR TREATMENT; VASCULAR ACCESS;
D O I
10.20960/angiologia.00008
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: stenoses in the arterio-venous fistulae (AVF) for hemodialysis are a very common problem and there is a long experience in its treatment by percutaneous angioplasty (PTA). These procedures, however, imply important needs for equipment, exposure to radiation and intravenous contrast that are not beneficial for the patient and make it more complex to perform. This study reviews our initial experience in ultrasound-guided angioplasty. Material and methods: prospective cohort of patients with native AVF dysfunction due to significant venous stenosis, undergoing a PTA ultrasound-guided. Puncture of the AVF, catheterization of the lesion, localization and inflation of the balloon and verification of the result were ultrasound-guided, with only a fistulography performed before and after the dilation. As a control-cases, patients intervened by the usual angiographic method were also collected. Results: of the 51 ATP performed on native AVF between February 2015 and September 2018, 27 were ultrasound-guided (mean age 65.3 years, 63% males). The technical success was 96%. In 26% of the cases, ATP was repeated due to residual stenosis after the angiographic image. There were 7.3% peri-procedural complications. 92% of the AVF were punctured at 24 h. Primary patency rates at 1 month, 6 months and 1 year was 100%, 64.8% and 43.6% and Assisted 100%, 87.2% and 74.8%, respectively. There were no significant differences in the immediate or late results with respect to angioplasty of AVF guided by angiography. Conclusions: ATP-FAV can be safe and effectively performed by Doppler ultrasound guidance. This method simplifies the logistics of the procedure although further improvements are needed to ensure that ultrasound is adequate to ensure the correct patency of the vessel.
引用
收藏
页码:183 / 189
页数:7
相关论文
共 50 条
[31]   Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons [J].
J. García-Medina ;
J. J. García-Alfonso .
CardioVascular and Interventional Radiology, 2017, 40 :750-754
[32]   Comparison of Post-surgical Potency Rates between Failing and Failed Arterio-venous Graft for Hemodialysis with Venous Anastomosis Stenosis [J].
Yun, Sang Chul ;
Song, Dan ;
Moon, Chul .
JOURNAL OF THE KOREAN SURGICAL SOCIETY, 2010, 78 (06) :410-418
[33]   Transluminal percutaneous angioplasty in the treatment of arteriovenous fistula stenosis [J].
Motellon, JL ;
deBustillo, EM ;
Barril, G ;
Tagarro, D ;
Tomero, JAS ;
Bernis, C ;
Alvarez, V ;
Traver, JA .
NEFROLOGIA, 1996, 16 (01) :54-60
[34]   Ultrasound-guided angioplasty of dialysis fistulas in renal transplant patients [J].
Szewczyk, Dariusz ;
Andziak, Piotr ;
Bojakowski, Krzysztof ;
Gora, Rafal ;
Gaciong, Maciej .
VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2019, 14 (04) :532-537
[35]   A new device for ultrasound-guided peripheral venous access [J].
Brugioni, Lucio ;
Barchetti, Marco ;
Tazzioli, Giovanni ;
Gelmini, Roberta ;
Girardis, Massimo ;
Bianchini, Marcello ;
Schepis, Filippo ;
Nicolini, Matteo ;
Pinelli, Giovanni ;
Martella, Pietro ;
Barozzi, Marco ;
Mori, Francesca ;
Scarabottini, Serena ;
Righetti, Andrea ;
Ravazzini, Mirco ;
Bertellini, Elisabetta .
JOURNAL OF VASCULAR ACCESS, 2019, 20 (03) :325-328
[36]   Influence of Wall Compliance on the Flow Patterns in a Patient-Specific Brachio-Cephalic Arterio-Venous Fistula [J].
Alam, Neda ;
Newport, David .
BIOMECHANICS, 2022, 2 (02) :158-173
[37]   Efficacy of ultrasound-guided percutaneous transluminal angioplasty for arteriovenous fistula stenosis or occlusion at juxta-anastomosis: A 3-year follow-up cohort study [J].
Gu, Hui ;
Wan, Ziming ;
Lai, Qi-Quan ;
Zhou, Yu ;
Tu, Bo ;
Hu, Bo ;
Chen, Ling ;
Gao, Xue-Jing .
JOURNAL OF VASCULAR SURGERY, 2021, 74 (01) :217-224
[38]   X-ray-guided and ultrasound-guided percutaneous transluminal angioplasty to treat arteriovenous fistula dysfunction in hemodialysis patients: A retrospective controlled study [J].
Gan, Zhen ;
Zhou, Liang ;
Wu, Xian ;
Gu, Chun-Feng ;
He, Xu ;
Guo, Jin-He .
JOURNAL OF VASCULAR ACCESS, 2023, 24 (02) :222-231
[39]   Safety and efficacy of an innovative external support device for de novo arterio-venous fistula creation: a French bicentric experience [J].
Hauguel, Alexandra ;
Firket, Louis ;
De Blic, Romain ;
Bonnet, Marie ;
Michel, Cassandre ;
Mallios, Alexandros .
JOURNAL OF CARDIOVASCULAR SURGERY, 2025, 66 (01) :30-36
[40]   Predictability and usefulness of intravascular ultrasound-guided angioplasty in patients with femoropopliteal lesions [J].
Jiang, Junhui ;
Xu, Weiguo .
INTERNATIONAL ANGIOLOGY, 2022, 41 (01) :74-81