On-site analysis of gold, palladium, or platinum in acidic aqueous matrix using liquid electrode plasma-optical emission spectrometry combined with ion-selective preconcentration

被引:18
作者
Barua, Suman [1 ,2 ]
Rahman, Ismail M. M. [3 ]
Miyaguchi, Maho [1 ]
Mashio, Asami S. [4 ]
Maki, Teruya [4 ]
Hasegawa, Hiroshi [4 ]
机构
[1] Kanazawa Univ, Grad Sch Nat Sci & Technol, Kanazawa, Ishikawa 9201192, Japan
[2] Univ Chittagong, Dept Appl Chem & Chem Engn, Chittagong 4331, Bangladesh
[3] Fukushima Univ, Inst Environm Radioact, 1 Kanayagawa, Fukushima, Fukushima 9601296, Japan
[4] Kanazawa Univ, Inst Sci & Engn, Kanazawa, Ishikawa 9201192, Japan
基金
日本学术振兴会;
关键词
Precious metals; Solid-phase extraction; Selective separation; Preconcentration; LEP-OES; On-site analysis; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; COLUMN PRECONCENTRATION; ONLINE PRECONCENTRATION; ENVIRONMENTAL-SAMPLES; PRECIOUS METALS; ICP-MS; RECOVERY; DISCHARGE; SEPARATION;
D O I
10.1016/j.snb.2018.05.132
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A technique for the concurrent on-site quantitative analysis of gold (Au), palladium (Pd), or platinum (Pt) in the aqueous acidic matrix has been proposed. The Au, Pd, or Pt in the matrix was selectively concentrated in macrocycle-equipped solid-phase extraction (SPE) system, followed by analysis of the concentrates in a portable liquid electrode plasma-optical emission spectrometer (LEP-OES). The SPE-retention or recovery behavior towards Au, Pd, or Pt has been optimized for solution pH, sample-loading flow-rates, eluent-type or eluent-volume, and matrix components. The SPE-assisted pre-treatment minimized interfering impacts due to the competing ions in solution and limitations in LEP-OES sensitivity at low Au, Pd, or Pt content in the matrix. The preconcentration factor was 250 for Au, Pd, or Pt. The LEP-OES operating variables such as applied voltage, ontime, off-time, and pulse count for applied voltage have been optimized to obtain distinct peaks in spectra for Au (lambda(max), 274.826 nm), Pd (lambda(max), 267.958 nm), and Pt (lambda(max), 270.240 nm). The limit of detection (3 sigma) for Au, Pd, Pt determination using the technique were found, respectively, as 0.8, 3.1, 57.3 ng mL(-1). The proposed method was applied to the analysis of Au, Pd, or Pt contents in the European Commission Joint Research Center certified reference material of wastewaters (ERM-CA713; recovery by the standard addition method, > 96%), and real aqueous waste from the plating process (recovery, > 95%). A relative standard deviation of <= 5% indicated a good precision in Au, Pd, or Pt analysis using the technique. The LEP-OES data-sets were also comparable with those obtained from the inductively coupled plasma optical emission spectrometric measurements for the same matrix.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 55 条
  • [1] Multi-element determination of Pt, Pd and Ir traces in environmental samples by ICP-MS after pre-concentration
    Alonso Castillo, Manuel L.
    Garcia de Torres, Amparo
    Vereda Alonso, Elisa
    Siles Cordero, Ma Teresa
    Cano Pavon, Jose Manuel
    [J]. TALANTA, 2012, 99 : 853 - 858
  • [2] [Anonymous], 2013, ERMCA713 EUR COMM JO
  • [3] [Anonymous], 2016, MH 5000 MEAS RANGE S
  • [4] [Anonymous], 2016, TECHN NOT MH 5000 US
  • [5] Baltzer N., 2014, PRECIOUS METALS BIOM
  • [6] Recent advances in the determination of the platinum group elements and gold
    Barefoot, RR
    Van Loon, JC
    [J]. TALANTA, 1999, 49 (01) : 1 - 14
  • [7] COEFFICIENT OF DETERMINATION - SOME LIMITATIONS
    BARRETT, JP
    [J]. AMERICAN STATISTICIAN, 1974, 28 (01) : 19 - 20
  • [8] Liquid electrode plasma-optical emission spectrometry combined with solid phase preconcentration for on-site analysis of lead
    Barua, Suman
    Rahman, Ismail M. M.
    Alam, Iftakharul
    Miyaguchi, Maho
    Sawai, Hikaru
    Maki, Teruya
    Hasegawa, Hiroshi
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1060 : 190 - 199
  • [9] On-line preconcentration of palladium(II) using a microcolumn packed with a chelating resin, and its subsequent determination by graphite furnace atomic absorption spectrometry
    Bosch Ojeda, Catalina
    Sanchez Rojas, Fuensanta
    Cano Pavon, Jose Manuel
    [J]. MICROCHIMICA ACTA, 2007, 158 (1-2) : 103 - 110
  • [10] EMISSION STUDIES ON A GLOW-DISCHARGE IN ATMOSPHERIC-PRESSURE AIR USING WATER AS A CATHODE
    CSERFALVI, T
    MEZEI, P
    APAI, P
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (12) : 2184 - 2188