In vitro evaluation of a rheolytic thrombectomy system for clot removal from five different temporary vena cava filters

被引:5
作者
Buecker, A
Neuerburg, J
SchmitzRode, T
Vorwerk, D
Guenther, RW
机构
[1] Clinic for Diagnostic Radiology, University of Technology Aachen, D-52074 Aachen
关键词
vena cava filters; temporary; thrombectomy; rheolytic; embolism; pulmonary; retrieval of;
D O I
10.1007/s002709900191
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the feasibility of thrombus removal from temporary vena cava filters using a rheolytic thrombectomy device and to assess the embolization rate of this procedure. Methods: Five temporary vena cava filters together with porcine thrombi were placed in a vena cava flow model (semitranslucent silicone tube of 23 mm diameter, pulsatile flow at a mean flow rate of 4 L/min), A rheolytic thrombectomy system (Hydrolyser) was used with a 9 Fr guiding catheter to remove the clots. The effluent was passed through filters of different size and the amount of embolized particles as well as the remaining thrombus were measured. Results: Thrombus removal rates ranged from 85% to 100%. Embolization rates between 47% and 60% were calculated for the different filters. Conclusion: The Hydrolyser is able to remove sufficiently high amounts of thrombus from temporary vena cava filters, However, the amount of embolized particles makes it impossible to utilize this method without special precautions against embolization.
引用
收藏
页码:448 / 451
页数:4
相关论文
共 17 条
[1]   COMPLICATIONS OF VENA-CAVA FILTERS [J].
ATHANASOULIS, CA .
RADIOLOGY, 1993, 188 (03) :614-615
[2]  
BUECKER A, 1996, J VASC INTERV RADIOL, V7, P445
[3]   EXPERIENCE WITH THE AMPLATZ RETRIEVABLE VENA-CAVA FILTER [J].
EPSTEIN, DH ;
DARCY, MD ;
HUNTER, DW ;
COLEMAN, CC ;
TADAVARTHY, SM ;
MURRAY, PD ;
CASTANEDAZUNIGA, WR ;
AMPLATZ, K .
RADIOLOGY, 1989, 172 (01) :105-110
[4]   CURRENT INDICATIONS FOR AND RESULTS OF GREENFIELD FILTER PLACEMENT [J].
GREENFIELD, LJ .
JOURNAL OF VASCULAR SURGERY, 1984, 1 (03) :502-504
[5]  
GUENTHER R W, 1985, Radiology, V156, P315
[6]   Temporary cava filter: Effective prophylaxis of pulmonary embolism in venous thromboses in the region of the pelvic vascular system and of the vena cava inferior? [J].
Kunisch, M ;
Rauber, K ;
Bachmann, G ;
Rau, WS .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 163 (06) :523-526
[7]   PRELIMINARY CLINICAL-EXPERIENCE WITH THE GUNTHER TEMPORARY INFERIOR VENA-CAVA FILTER [J].
MILLWARD, SF ;
BORMANIS, J ;
BURBRIDGE, BE ;
MARKMAN, SJ ;
PETERSON, RA .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (06) :863-868
[8]  
NAGAKAWA N, 1994, J VASC INTERV RADIOL, V5, P507
[9]   NEW RETRIEVABLE PERCUTANEOUS VENA-CAVA FILTER - EXPERIMENTAL IN-VITRO AND IN-VIVO EVALUATION [J].
NEUERBURG, J ;
GUNTHER, RW ;
RASSMUSSEN, E ;
VORWERK, D ;
TONN, K ;
HANDT, S ;
KUPPER, W ;
HANSEN, JV .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1993, 16 (04) :224-229
[10]   DEVELOPMENTS IN INFERIOR VENA-CAVA FILTERS - A EUROPEAN VIEWPOINT [J].
NEUERBURG, J ;
GUNTHER, RW .
SEMINARS IN INTERVENTIONAL RADIOLOGY, 1994, 11 (04) :349-357