Full scale behavior of a small size vertical axis wind turbine

被引:18
作者
Pagnini, Luisa [1 ]
Piccardo, Giuseppe [1 ]
Repetto, Maria Pia [1 ]
机构
[1] Univ Genoa, DICCA Polytech Sch, Genoa, Italy
关键词
Damping ratio estimates; Experimental power curve; Small size wind turbines; Turbulence effects; Vertical axis wind turbine (VAWT); VAWT identification; POWER CURVE; PITCH-ANGLE; PERFORMANCE; SYSTEM; IDENTIFICATION; PREDICTION; TOWERS; SPEED; VIBRATIONS; FREQUENCY;
D O I
10.1016/j.renene.2018.04.032
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper shows the on-going experimental campaign carried out over a small size vertical axis wind turbine in the facility of the Savona Harbor. Investigations mainly concern two issues: power production assessment and full-scale structural behavior. The first one highlights the importance of a deep knowledge of the local orography and of the wind characteristics (e.g., turbulence intensity); in the absence of reliable wind data it is impossible to properly estimate the performance of the system. The latter allows to identify the possible critical aspects of the structural system (e.g., in terms of resonance conditions) and to investigate the actual dynamic behavior (e.g., in terms of dissipative capacity), necessary for assessing the useful life. The paper points out how these two issues are closely related. Results obtained can provide indications suitable for improving future installations. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:41 / 55
页数:15
相关论文
共 60 条
[1]   Pitch angle control for a small-scale Darrieus vertical axis wind turbine with straight blades (H-Type VAWT) [J].
Abdalrahman, Gebreel ;
Melek, William ;
Lien, Fue-Sang .
RENEWABLE ENERGY, 2017, 114 :1353-1362
[2]   Comparison of Energy Yield of Small Wind Turbines in Low Wind Speed Areas [J].
Ani, Samuel O. ;
Polinder, Henk ;
Ferreira, Jan Abraham .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2013, 4 (01) :42-49
[3]  
[Anonymous], 2016, Global Wind Report: Annual Market Update 2015
[4]  
[Anonymous], 2015, INTRO OPERATIONAL MO, DOI DOI 10.1002/9781118535141
[5]  
[Anonymous], P 5 INT C COMP STOCH
[6]  
[Anonymous], 1999, JOURNALOFVIBRATIONAN
[7]   Evaluation of damping estimates by automated Operational Modal Analysis for offshore wind turbine tower vibrations [J].
Bajric, Anela ;
Hogsberg, Jan ;
Rudinger, Finn .
RENEWABLE ENERGY, 2018, 116 :153-163
[8]   On a self-start Darrieus wind turbine: Blade design and field tests [J].
Batista, N. C. ;
Melicio, R. ;
Mendes, V. M. F. ;
Calderon, M. ;
Ramiro, A. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 52 :508-522
[9]   Analysis of Different Blade Architectures on small VAWT Performance [J].
Battisti, L. ;
Brighenti, A. ;
Benini, E. ;
Castelli, M. Raciti .
SCIENCE OF MAKING TORQUE FROM WIND (TORQUE 2016), 2016, 753
[10]   A Data-Driven Diagnostic Framework for Wind Turbine Structures: A Holistic Approach [J].
Bogoevska, Simona ;
Spiridonakos, Minas ;
Chatzi, Eleni ;
Dumova-Jovanoska, Elena ;
Hoeffer, Rudiger .
SENSORS, 2017, 17 (04)