Retinal Nerve Fiber Layer Measurements by Scanning Laser Polarimetry With Enhanced Corneal Compensation in Healthy Subjects

被引:6
作者
Rao, Harsha L. [1 ,2 ]
Venkatesh, Chirravuri R. [1 ]
Vidyasagar, Kelli [1 ]
Yadav, Ravi K. [1 ]
Addepalli, Uday K. [1 ]
Jude, Aarthi [1 ]
Senthil, Sirisha [1 ]
Garudadri, Chandra S. [1 ]
机构
[1] LV Prasad Eye Inst, VST Glaucoma Ctr, Hyderabad 500034, Andhra Pradesh, India
[2] LV Prasad Eye Inst, Ctr Clin Epidemiol & Biostat, Hyderabad 500034, Andhra Pradesh, India
关键词
scanning laser polarimetry; enhanced corneal compensation; predictors; repeatability; ATYPICAL BIREFRINGENCE PATTERN; OPTICAL COHERENCE TOMOGRAPHY; GLAUCOMATOUS EYES; THICKNESS; MYOPIA; DISC;
D O I
10.1097/IJG.0b013e318286ffa5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the (i) effects of biological (age and axial length) and instrument-related [typical scan score (TSS) and corneal birefringence] parameters on the retinal nerve fiber layer (RNFL) measurements and (ii) repeatability of RNFL measurements with the enhanced corneal compensation (ECC) protocol of scanning laser polarimetry (SLP) in healthy subjects. Methods: In a cross-sectional study, 140 eyes of 73 healthy subjects underwent RNFL imaging with the ECC protocol of SLP. Linear mixed modeling methods were used to evaluate the effects of age, axial length, TSS, and corneal birefringence on RNFL measurements. One randomly selected eye of 48 subjects from the cohort underwent 3 serial scans during the same session to determine the repeatability. Results: Age significantly influenced all RNFL measurements. RNFL measurements decreased by 1 mu m for every decade increase in age. TSS affected the overall average RNFL measurement (beta = -0.62, P = 0.003), whereas residual anterior segment retardance affected the superior quadrant measurement (beta = 1.14, P = 0.01). Axial length and corneal birefringence measurements did not influence RNFL measurements. Repeatability, as assessed by the coefficient of variation, ranged between 1.7% for the overall average RNFL measurement and 11.4% for th nerve fiber indicator. Conclusions: Age significantly affected all RNFL measurements with the ECC protocol of SLP, whereas TSS and residual anterior segment retardance affected the overall average and the superior average RNFL measurements, respectively. Axial length and corneal birefringence measurements did not influence any RNFL measurements. RNFL measurements had good intrasession repeatability. These results are important while evaluating the change in structural measurements over time in glaucoma patients.
引用
收藏
页码:589 / 593
页数:5
相关论文
共 24 条
[1]  
[Anonymous], 2007, Linear Mixed Models: A Practical Guide Using Statistical Software
[2]   Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation [J].
Bagga, H ;
Greenfield, DS ;
Feuer, WJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (03) :437-446
[3]  
Bland JM, 1996, BRIT MED J, V313, P744
[4]   Statistics notes: Measurement error proportional to the mean .23. [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7049) :106-106
[5]   The effect of atypical birefringence patterns on glaucoma detection using scanning laser polarimetry with variable corneal compensation [J].
Bowd, Christopher ;
Medeiros, Felipe A. ;
Weinreb, Robert N. ;
Zangwill, Linda M. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) :223-227
[6]   The effect of ageing on retinal nerve fibre layer thickness: an evaluation by scanning laser polarimetry with variable corneal compensation [J].
Da Pozzo, Stefano ;
Iacono, Pierluigi ;
Marchesan, Roberta ;
Minutola, Daniela ;
Ravalico, Giuseppe .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (03) :375-379
[7]   Relation between size of optic disc and thickness of retinal nerve fibre layer in normal subjects [J].
Funaki, S ;
Shirakashi, M ;
Abe, H .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (11) :1242-1245
[8]   The Impact of Retardance Pattern Variability on Nerve Fiber Layer Measurements over Time Using GDx with Variable and Enhanced Corneal Compensation [J].
Grewal, Dilraj S. ;
Sehi, Mitra ;
Cook, Richard J. ;
Greenfield, David S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) :4516-4524
[9]   Diagnostic accuracy of scanning laser polarimetry with enhanced versus variable corneal compensation [J].
Mai, T. A. ;
Reus, N. J. ;
Lemij, H. G. .
OPHTHALMOLOGY, 2007, 114 (11) :1988-1993
[10]   Detection of glaucoma using scanning laser polarimetry with enhanced corneal compensation [J].
Medeiros, Felipe A. ;
Bowd, Christopher ;
Zangwill, Linda M. ;
Patel, Chirag ;
Weinreb, Robert N. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) :3146-3153