Validation of a novel smartphone application-enabled, patient-operated skin barrier device

被引:19
作者
Grinich, Erin E. [1 ]
Shah, Anuja, V [2 ]
Simpson, Eric L. [2 ]
机构
[1] Oregon Hlth & Sci Univ, Sch Med, Portland, OR 97201 USA
[2] Oregon Hlth & Sci Univ, Dept Dermatol, Portland, OR 97201 USA
关键词
atopic dermatitis; barrier; capacitance; device; hydration; transepidermal water loss; TRANSEPIDERMAL WATER-LOSS; ATOPIC-DERMATITIS; RELIABILITY;
D O I
10.1111/srt.12692
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background Transepidermal water loss (TEWL) and surface capacitance measure skin barrier permeability and stratum corneum (SC) hydration, respectively, and are frequently utilized in atopic dermatitis clinical trials. Many barrier devices are costly and often used only in the academic setting. GPSkin is a low-cost, patient-operated device that measures both TEWL and SC hydration. This study aimed to test the reliability of GPSkin and assess its correlation with current industry standards. Materials and Methods GPSkin was compared to the Biox AquaFlux (TEWL) and Courage-Khazaka Corneometer (SC hydration). Participants with healthy skin (n = 50) collected measurements with GPSkin in Trial 1 without any device education and in Trial 2 with additional instruction. In Trial 2, the investigator also performed measurements with GPSkin. Spearman's coefficients (r(s)) were performed to assess device correlation. Intraclass correlation coefficients (ICC) were calculated to determine reliability. Results Overall, GPSkin was moderately correlated with current industry device measurements for TEWL (Trial 1 r(s):0.48; Trial 2 r(s):0.40 participant, 0.34 investigator) and SC hydration (Trial 1 r(s):0.63; Trial 2 r(s):0.45). GPSkin demonstrated "good" test-retest reliability for both TEWL (ICC: 0.89) and SC hydration (ICC: 0.85) measurements when participants were provided with some device education. There was no difference in reliability between participants provided with device education and investigators. Conclusion Based on these findings, we concluded that GPSkin provides reasonably precise and reliable measurements of SC hydration and TEWL as compared to current devices.
引用
收藏
页码:612 / 617
页数:6
相关论文
共 18 条
[1]   Reliability of Repeated Measurements on Post-Burn Scars with Corneometer CM 825® [J].
Anthonissen, M. ;
Daly, D. ;
Peeters, R. ;
Van Brussel, M. ;
Fieuws, S. ;
Moortgat, P. ;
Flour, M. ;
Van den Kerckhove, E. .
SKIN RESEARCH AND TECHNOLOGY, 2015, 21 (03) :302-312
[2]  
AquaFlux B, 2013, BIOX AQUAFLUX COND C
[3]   Evaluation of Immediate and 12-Week Effects of a Smartphone Sun-Safety Mobile Application A Randomized Clinical Trial [J].
Buller, David B. ;
Berwick, Marianne ;
Lantz, Kathy ;
Buller, Mary Klein ;
Shane, James ;
Kane, Ilima ;
Liu, Xia .
JAMA DERMATOLOGY, 2015, 151 (05) :505-512
[4]  
Courage-Khazaka, SCI DEV CORN CM 825
[5]   A functional mechanistic study of the effect of emollients on the structure and function of the skin barrier [J].
Danby, S. G. ;
Chalmers, J. ;
Brown, K. ;
Williams, H. C. ;
Cork, M. J. .
BRITISH JOURNAL OF DERMATOLOGY, 2016, 175 (05) :1011-1019
[6]   The potential of metabolic interventions to enhance transdermal drug delivery [J].
Elias, PM ;
Tsai, J ;
Menon, GK ;
Holleran, WM ;
Feingold, KR .
JOURNAL OF INVESTIGATIVE DERMATOLOGY SYMPOSIUM PROCEEDINGS, 2002, 7 (01) :79-85
[7]   Transepidermal water loss reflects permeability barrier status:: validation in human and rodent in vivo and ex vivo models [J].
Fluhr, Joachim W. ;
Feingold, Kenneth R. ;
Elias, Peter M. .
EXPERIMENTAL DERMATOLOGY, 2006, 15 (07) :483-492
[8]  
GPower, M GPSKIN BARR
[9]   Intrinsically defective skin barrier function in children with atopic dermatitis correlates with disease severity [J].
Gupta, Jayanta ;
Grube, Emilie ;
Ericksen, Mark B. ;
Stevenson, Michelle D. ;
Lucky, Anne W. ;
Sheth, Anita P. ;
Assa'ad, Amal H. ;
Hershey, Gurjit K. Khurana .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2008, 121 (03) :725-730
[10]  
Imhof R. E., 2009, International Journal of Cosmetic Science, V31, P97, DOI 10.1111/j.1468-2494.2008.00476.x