A generalized 4D image registration scheme for targeted radionuclide therapy dosimetry

被引:8
|
作者
Papavasileiou, Periklis
Divoli, Antigoni
Hatziioannou, Kostas
Flux, Glenn D.
机构
[1] Papageorgiou Gen Hosp, Dept Phys Med, Thessaloniki 54603, Greece
[2] Inst Canc Res, Joint Dept Phys, Sutton, Surrey, England
[3] Royal Marsden Hosp NHS Fdn Trust, Sutton, Surrey, England
关键词
image registration; radionuclide therapy dosimetry; polynomial fitting;
D O I
10.1089/cbr.2007.310
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
An iterative, generalized four-dimensional (4D) method is presented in this paper that allows simultaneous registration of a series of single-photon emission computed tomography (SPECT) scans acquired in the course of a radionuclide therapy or pretherapy tracer study. The method combines temporal information with voxel-based similarity criteria to carry out simultaneous registration of the SPECT scans. A polynomial function was fitted to the maximum counts of each tumor site over the 4D study. Each tumor site was normalized to its maximum on the reference scan, and a template 4D dataset was generated, employing the polynomial fitting and the normalization map. Then, each 3D scan was registered to the corresponding simulated scan, using a 3D similarity criterion. The correlation coefficient (CC), the mutual information (MI), and the sum-of-absolute differences (SAD) similarity criteria were employed. Simulated data, based on a head-neck I-131-MIBG study, were used to compare the proposed method for 4D registration with sequential 3D registration. Sequential 3D registration resulted in residual registration errors of 3.5 +/- 2.5, 3.2 +/- 2.0, and 7.0 +/- 3.5 mm for the CC, MI, and SAD criteria respectively, whereas the corresponding 4D method gave errors of 2.4 +/- 1.6, 1.9 +/- 1.1, and 5.3 +/- 2.9 mm for the CC, MI, and SAD criteria, respectively. The 4D method was applied to Re-186 HEDP SPECT patient studies and registration was verified by a dual-cursor display tool.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 45 条
  • [1] 4D Medical Image Registration: A Survey
    Girija, J.
    Murthy, G. N. Krishna
    Reddy, P. Chenna
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON INTELLIGENT SUSTAINABLE SYSTEMS (ICISS 2017), 2017, : 539 - 547
  • [2] BIGDOSE: software for 3D personalized targeted radionuclide therapy dosimetry
    Li, Tiantian
    Zhu, Licheng
    Lu, Zhonglin
    Song, Na
    Lin, Ko-Han
    Mok, Greta S. P.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (01) : 160 - 170
  • [3] Evaluation of sequential SPECT and CT for targeted radionuclide therapy dosimetry
    Tiantian Li
    Nien-Yun Wu
    Na Song
    Greta S. P. Mok
    Annals of Nuclear Medicine, 2018, 32 : 34 - 43
  • [4] Evaluation of sequential SPECT and CT for targeted radionuclide therapy dosimetry
    Li, Tiantian
    Wu, Nien-Yun
    Song, Na
    Mok, Greta S. P.
    ANNALS OF NUCLEAR MEDICINE, 2018, 32 (01) : 34 - 43
  • [5] Optimal Landmark Selection for Registration of 4D Confocal Image Stacks in Arabidopsis
    Mkrtchyan, Katya
    Chakraborty, Anirban
    Roy-Chowdhury, Amit K.
    IEEE-ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2017, 14 (02) : 457 - 467
  • [6] Dependence of ventilation image derived from 4D CT on deformable image registration and ventilation algorithms
    Latifi, Kujtim
    Forster, Kenneth M.
    Hoffe, Sarah E.
    Dilling, Thomas J.
    van Elmpt, Wouter
    Dekker, Andre
    Zhang, Geoffrey G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 150 - 162
  • [7] Effective lung ventilation estimation based on 4D CT image registration and supervoxels
    Xue, Peng
    Fu, Yu
    Zhang, Jingyang
    Ma, Lei
    Ren, Meirong
    Zhang, Zhili
    Dong, Enqing
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [8] Creation of 4D imaging data using open source image registration software
    Wong, Kenneth H.
    Ibanez, Luis
    Popa, Teo
    Cleary, Kevin
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [9] Technical Note: Virtual CT for reducing CT dose in targeted radionuclide therapy dosimetry
    Li, Tiantian
    Mok, Greta S. P.
    MEDICAL PHYSICS, 2018, 45 (11) : 5138 - 5144
  • [10] Lung Respiratory Motion Estimation Based on Fast Kalman Filtering and 4D CT Image Registration
    Xue, Peng
    Fu, Yu
    Ji, Huizhong
    Cui, Wentao
    Dong, Enqing
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (06) : 2007 - 2017