Influence of skin colour on diagnostic accuracy of the jaundice meter JM 103 in newborns

被引:24
作者
Samiee-Zafarghandy, S. [1 ,2 ]
Feberova, J. [1 ]
Williams, K. [3 ]
Yasseen, A. S. [3 ]
Perkins, S. L. [4 ]
Lemyre, B. [1 ]
机构
[1] Ottawa Gen Hosp, Dept Obstet Gynecol & Newborn Care, Ottawa, ON K1H 8L6, Canada
[2] McMaster Childrens Hosp, Div Neonatol, Dept Pediat, Hamilton, ON, Canada
[3] Childrens Hosp Eastern Ontario, Clin Res Unit, Ottawa, ON K1H 8L1, Canada
[4] Ottawa Gen Hosp, Dept Pathol & Lab Med, Ottawa, ON K1H 8L6, Canada
来源
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION | 2014年 / 99卷 / 06期
关键词
TRANSCUTANEOUS BILIRUBIN MEASUREMENT; TOTAL SERUM BILIRUBIN; HYPERBILIRUBINEMIA; RISK; TERM;
D O I
10.1136/archdischild-2013-305699
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Aim To assess the diagnostic accuracy of the JM 103 as a screening tool for neonatal jaundice and explore differential effects based on skin colour. Methods We prospectively compared the transcutaneous bilirubin (TcB) and serum bilirubin (TSB) measurements of newborns over a 3 month-period. Skin colour was assigned via reference colour swatches. Diagnostic measures of the TcB/TSB comparison were made and clinically relevant TcB cut-off values were determined for each skin colour group. Results 451 infants (51 light, 326 medium and 74 dark skin colour) were recruited. The association between TcB and TSB was high for all skin colours (r(s)>0.9). The Bland-Altman analysis showed an absolute mean difference between the two measures of 13.3 +/- 26.4 mu mol/L with broad limits of agreement (-39.4-66.0 mu mol/L), with TcB underestimating TSB in light and medium skin colours and overestimating in dark skin colour. Diagnostic measures were also consistently high across skin colours, with no clinically significant differences observed. Conclusions The JM 103 is a useful screening tool to identify infants in need of serum bilirubin, regardless of skin colour. The effect of skin colour on the accuracy of this device at high levels of serum bilirubin could not be assessed fully due to small numbers in the light and dark groups.
引用
收藏
页码:F480 / F484
页数:5
相关论文
共 25 条
  • [1] AAP subcommittee on neonatal hyperbilirubinemia, 2004, PEDIATRICS, V108, P763
  • [2] Guidelines for detection, management and prevention of hyperbilirubinemia in term and late preterm newborn infants (35 or more weeks' gestation) - Summary
    Aziz, Khalid
    Barrington, Keith J.
    Embree, Joanne
    Kirpalani, Haresh
    Sankaran, Koravangattu
    Whyte, Hilary
    Whyte, Robin
    Farine, Dan
    Keegan, David
    Lefebvre, Francine
    McCourt, Catherine
    Premji, Shahirose
    Solimano, Alfonso
    Stark, Ann
    Symington, Amanda
    Barrington, Keith
    Sankaran, Koravangattu
    [J]. PAEDIATRICS & CHILD HEALTH, 2007, 12 (05) : 401 - 407
  • [3] Bhutani-based nomograms for the prediction of significant hyperbilirubinaemia using transcutaneous measurements of bilirubin
    Bental, Y. A.
    Shiff, Y.
    Dorsht, N.
    Litig, E.
    Tuval, L.
    Mimouni, F. B.
    [J]. ACTA PAEDIATRICA, 2009, 98 (12) : 1902 - 1908
  • [4] Predictive ability of a predischarge hour-specific serum bilirubin for subsequent significant hyperbilirubinemia in healthy term and near-term newborns
    Bhutani, VK
    Johnson, L
    Sivieri, EM
    [J]. PEDIATRICS, 1999, 103 (01) : 6 - 14
  • [5] Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia
    Bhutani, VK
    Gourley, GR
    Adler, S
    Kreamer, B
    Dalin, C
    Johnson, LH
    [J]. PEDIATRICS, 2000, 106 (02) : E17
  • [6] Prediction of severe hyperbilirubinaemia using the Bilicheck transcutaneous bilirubinometer
    Boo, Nem-Yun
    Ishak, Shareena
    [J]. JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2007, 43 (04) : 306 - 311
  • [7] Statistical methodology .1. Incorporating the prevalence of disease into the sample size calculation for sensitivity and specificity
    Buderer, NMF
    [J]. ACADEMIC EMERGENCY MEDICINE, 1996, 3 (09) : 895 - 900
  • [8] Transcutaneous bilirubin measurement at the time of hospital discharge in a multiethnic newborn population
    Campbell, Douglas M.
    Danayan, Karoon C.
    McGovern, Valleverdina
    Cheema, Sohail
    Stade, Brenda
    Sgro, Michael
    [J]. PAEDIATRICS & CHILD HEALTH, 2011, 16 (03) : 141 - 145
  • [9] Transcutaneous bilirubinometry: Its role in the assessment of neonatal jaundice
    Dai, J
    Parry, DM
    Krahn, J
    [J]. CLINICAL BIOCHEMISTRY, 1997, 30 (01) : 1 - 9
  • [10] Transcutaneous bilirubinometry in healthy preterm newborns
    Donzelli, G
    Pratesi, S
    [J]. CLINICAL BIOCHEMISTRY, 2000, 33 (06) : 505 - 508