Experimental study on dual recirculation of polymer electrolyte membrane fuel cell

被引:40
|
作者
Jiang, Hongliang [1 ,2 ]
Xu, Liangfei [1 ,2 ,3 ]
Fang, Chuan [1 ,2 ]
Zhao, Xingwang [1 ,2 ]
Hu, Zunyan [1 ,2 ]
Li, Jianqiu [1 ,2 ]
Ouyang, Minggao [1 ,2 ]
机构
[1] Tsinghua Univ, State Key Lab Automot Safety & Energy, Beijing 100084, Peoples R China
[2] Collaborat Innovat Ctr Elect Vehicles Beijing, Beijing 100081, Peoples R China
[3] Forschungszentrum Julich, Inst Energy & Climate Res, IEK Electrochem Proc Engn 3, D-52425 Julich, Germany
基金
中国国家自然科学基金;
关键词
Polymer electrolyte membrane fuel cell; Anodic recirculation; Cathodic recirculation; Voltage clamping; Self-humidification; Durability; HYDROGEN FLOW; AIR STREAM; DEGRADATION; SYSTEM; DURABILITY;
D O I
10.1016/j.ijhydene.2017.04.183
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Durability and start-up ability in sub-zero environment are two technical bottlenecks of vehicular polymer electrolyte membrane (PEM) fuel cell systems. With exhaust gas recirculation on the anode and cathode side, the cell voltage at low current density can be reduced, and the membrane can be humidified without external humidifier. They may be helpful to prolong the working lifetime and to promote the start-up ability. This paper presents an experimental study on a PEM fuel cell system with anodic and cathodic recirculation. The system is built up based on a 10 kW fuel cell stack, which consists of 50 cells and has an active area of 261 cm(2). A cathodic recirculation pump and a hydrogen recirculation pump are utilized on the cathode and anode side, respectively. Key parameters, e.g., stack current, stack voltage, cell voltage, air flow, relative humidity on the cathode side, oxygen concentration at the inlet and outlet of the cathode side, are measured. Results show that: 1) with a cathodic recirculation the system gets good self humidification effect, which is similar to that with an external humidifier; 2) with a cathodic recirculation and a reduction of fresh air flux, the cell voltage can be obviously reduced; 3) with an anodic recirculation the cell voltage can also be reduced due to a reduction in the hydrogen partial pressure, the relative humidity on the cathode side is a little smaller than the case with only cathode recirculation. It indicates that, for our stack the cathodic recirculation is effective to clamp cell voltage at low current density, and a self-humidification system is possible with cathodic recirculation. Further study will focus on the dynamic model and control of the dual recirculation fuel cell system. (C) 2017 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:18551 / 18559
页数:9
相关论文
共 50 条
  • [1] Experimental study on the performance improvement of polymer electrolyte membrane fuel cell with dual air supply
    Kang, Dong Gyun
    Shin, Dong Kyu
    Kim, Sunjin
    Kim, Min Soo
    RENEWABLE ENERGY, 2019, 141 : 669 - 677
  • [2] Experimental analysis of an ejector for anode recirculation in a 10 kW polymer electrolyte membrane fuel cell system
    Wang, Xuhui
    Lu, Yikang
    Zhang, Baitao
    Liu, Jinling
    Xu, Sichuan
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (03) : 1925 - 1939
  • [3] Experimental study on the effects of the performance of polymer electrolyte membrane fuel cell
    Kim, Hong Gun
    Kwac, Lee Ku
    Kang, Sung-Soo
    Kang, Young Woo
    ECO-MATERIALS PROCESSING AND DESIGN VIII, 2007, 544-545 : 993 - +
  • [4] Modelling a polymer electrolyte membrane fuel cell system with anodic and cathodic exhaust gas recirculation
    Zhang, Jianhui
    Bastek, Sebastian
    Xu, Liangfei
    Li, Jianqiu
    Hu, Zunyan
    Wang, Yongzhan
    Ouyang, Minggao
    2019 3RD CONFERENCE ON VEHICLE CONTROL AND INTELLIGENCE (CVCI), 2019, : 436 - 441
  • [5] Effect of Hydrogen Recirculation on the Performance of Polymer Electrolyte Membrane Fuel Cell with Dead Ended Mode
    Kim, Junseob
    Kim, Junbom
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2019, 57 (04): : 531 - 538
  • [6] Development of Dual-Cell Structured Polymer Electrolyte Membrane Fuel Cell Stack
    Song, Hwa-Seob
    Hong, Jong-Chul
    Jang, Gyu-Jin
    Son, Hui-Jeong
    Han, Seong-Ho
    JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2013, 10 (04):
  • [7] Composite membrane for polymer electrolyte membrane fuel cell
    Kim, CS
    Yang, TH
    Kwak, SH
    Yoon, KH
    SOLID STATE IONICS: THE SCIENCE AND TECHNOLOGY OF IONS IN MOTION, 2004, : 127 - 134
  • [8] Experimental Study of Polymer Electrolyte Membrane Fuel Cell Performance Under Low Operating Temperatures
    Cha, Dowon
    Kim, Bosung
    Kim, Yongchan
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2014, 38 (08) : 687 - 693
  • [9] Reduction of Hydrogen Transfer by Constrained Control of Anode Hydrogen Recirculation in a Polymer Electrolyte Membrane Fuel Cell
    Ebadighajari, Alireza
    DeVaal, Jake
    Golnaraghi, Farid
    2017 IEEE 56TH ANNUAL CONFERENCE ON DECISION AND CONTROL (CDC), 2017,
  • [10] Self-Humidification of a Polymer Electrolyte Membrane Fuel Cell System With Cathodic Exhaust Gas Recirculation
    Xu, Liangfei
    Fang, Chuan
    Hu, Junming
    Cheng, Siliang
    Li, Jianqiu
    Ouyang, Minggao
    Lehnert, Werner
    JOURNAL OF ELECTROCHEMICAL ENERGY CONVERSION AND STORAGE, 2018, 15 (02)