Rod-like CuO nanoparticles/waste masks carbon modified glassy carbon electrode as a voltammetric nanosensor for the sensitive determination of anti-cancer drug pazopanib in biological and pharmaceutical samples

被引:24
|
作者
Bilge, Selva [1 ]
Dogan-Topal, Burcu [2 ]
Atici, Esen Bellur [3 ]
Sinag, Ali [1 ]
Ozkan, Sibel A. [2 ]
机构
[1] Ankara Univ, Fac Sci, Dept Chem, Ankara, Turkey
[2] Ankara Univ, Fac Pharm, Dept Analyt Chem, Ankara, Turkey
[3] DEVA Holding AS, R&D Ctr, Karaagac Mh Fatih Blv 26, TR-59510 Kapakh, Tekirdag, Turkey
关键词
Nanosensor; Electrooxidation; Pazopanib; Hydrothermal carbonization; Waste masks; Rod-like CuO nanoparticles;
D O I
10.1016/j.snb.2021.130109
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, the first voltammetric method is developed for the detection of pazopanib (PZB), a pharmaceutically active ingredient belonging to the tyrosine kinase inhibitor class, using a modified glassy carbon electrode (GCE). Rod-like CuO nanoparticles synthesized by hydrothermal method and finger-like carbon material obtained from hydrothermal carbonization (HTC) of waste masks (M) were used as modification agents. The chemical structure and surface morphology of the synthesized materials were elucidated using various analytical techniques. The results show that carbon material has a core-shell structure, a critical property that increases electrical conductivity. Thus, the effects of both nanoparticles and carbon material on the electrooxidation behavior of pazopanib were investigated and compared. The effect of scan rate, pH, and supporting electrolyte on the voltammetric response of pazopanib was investigated on bare and modified GCE. The possible electrochemical oxidation mechanism was discussed with model drugs on bare GCE. The electrooxidation of PZB was an adsorption-controlled process on modified GCE at pH 7.0 phosphate buffer solution as proved by cyclic voltammetry (CV). All parameters of stripping conditions and square wave voltammetry (SWV) were optimized. The calibration curve was linear in the range of 2.0 x 10-10-1.0 x 10-6 M by adsorptive stripping square wave voltammetry (AdSSWV). The proposed method was used for the quantification of pazopanib in human serum samples and pharmaceutical dosage forms with satisfactory precision and accuracy. The method showed excellent analytical performance at nano- detection levels. Besides, the nanosensor was tested in the presence of some interfering compounds and ions.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Yang, Suling
    Qu, Lingbo
    Yang, Ran
    Li, Jianjun
    Yu, Lanlan
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (07) : 1371 - 1378
  • [2] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Suling Yang
    Lingbo Qu
    Ran Yang
    Jianjun Li
    Lanlan Yu
    Journal of Applied Electrochemistry, 2010, 40 : 1371 - 1378
  • [3] Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of noscapine in biological and pharmaceutical samples
    Rezaei, Behzad
    Zare, S. Zohreh Mirahmadi
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (01): : 292 - 299
  • [4] Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of leucine in biological and pharmaceutical samples
    Rezaei, B.
    Zare, Z. Mirahmadi
    ANALYTICAL LETTERS, 2008, 41 (12) : 2267 - 2286
  • [5] Voltammetric sensor for an anti-cancer drug cisplatin based on bismuth nanoparticles/graphene modified glassy carbon electrode
    Khumngern, Suntisak
    Choosang, Jittima
    Kanatharana, Proespichaya
    Thavarungkul, Panote
    Numnuam, Apon
    TALANTA, 2024, 267
  • [6] Multi-walled carbon nanotube modified glassy carbon electrode as a voltammetric nanosensor for the sensitive determination of anti-viral drug valganciclovir in pharmaceuticals
    Dogan-Topal, Burcu
    Bozal-Palabiyik, Burcin
    Uslu, Bengi
    Ozkan, Sibel A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 841 - 847
  • [7] Electrochemical behavior of an anti-cancer drug at glassy carbon electrode and its determination in pharmaceutical formulations
    Kalanur, Shankara S.
    Seetharamappa, Jaldappagari
    Mamatha, Gangeenahalli P.
    Hadagali, Manjunatha D.
    Kandagal, Pradeep B.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2008, 3 (07): : 756 - 767
  • [8] SnO2 nanoparticles/waste masks carbon hybrid materials for DNA biosensor application on voltammetric detection of anti-cancer drug pazopanib
    Bilge, Selva
    Topal, Burcu Dogan
    Caglayan, Mehmet Gokhan
    Unal, Mehmet Altay
    Nazir, Hasan
    Atici, Esen Bellur
    Sinag, Ali
    Ozkan, Sibel A.
    BIOELECTROCHEMISTRY, 2023, 150
  • [9] Sensitive detection of colchicine at a glassy carbon electrode modified with magnetic ionic liquid/CuO nanoparticles/carbon nanofibers in pharmaceutical and plasma samples
    Afzali, Moslem
    Mostafavi, Ali
    Shamspur, Tayebeh
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (07) : 1753 - 1764
  • [10] Sensitive detection of colchicine at a glassy carbon electrode modified with magnetic ionic liquid/CuO nanoparticles/carbon nanofibers in pharmaceutical and plasma samples
    Moslem Afzali
    Ali Mostafavi
    Tayebeh Shamspur
    Journal of the Iranian Chemical Society, 2020, 17 : 1753 - 1764