A Biomechanical Comparison of Distal Fixation for Bridge Plating in a Distal Radius Fracture Model

被引:17
作者
Alluri, Ram K. [1 ]
Bougioukli, Sofia [1 ]
Stevanovic, Milan [1 ]
Ghiassi, Alidad [1 ]
机构
[1] Univ Southern Calif, Keck Med Ctr, Dept Orthopaed Surg, Los Angeles, CA 90089 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2017年 / 42卷 / 09期
关键词
Biomechanics; bridge plate; distal fixation; radius fracture; VOLAR LOCKING PLATE; EXTERNAL FIXATION; COMPLICATIONS; STABILITY; WRIST;
D O I
10.1016/j.jhsa.2017.05.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To compare the biomechanical properties of second versus third metacarpal distal fixation when using a radiocarpal spanning distraction plate in an unstable distal radius fracture model. Methods Biomechanical evaluation of the radiocarpal spanning distraction plate comparing second versus third metacarpal distal fixation was performed using a standardized model of an unstable wrist fracture in 10 matched-pair cadaveric specimens. Each fixation construct underwent a controlled cyclic loading protocol in flexion and extension. The resultant displacement and stiffness were calculated at the fracture site. After cyclic loading, each specimen was loaded to failure. The stiffness, maximum displacement, and load to failure were compared between the 2 groups. Results Cyclic loading in flexion demonstrated that distal fixation to the third metacarpal resulted in greater stiffness compared with the second metacarpal. There was no significant difference between the 2 groups with regards to maximum displacement at the fracture site in flexion. Cyclic loading in extension demonstrated no significant difference in stiffness or maximum displacement between the 2 groups. The average load to failure was similar for both groups. Conclusions Fixation to the third metacarpal resulted in greater stiffness in flexion. All other biomechanical parameters were similar when comparing distal fixation to the second or third metacarpal in distal radius fractures stabilized with a spanning internal distraction plate. (Copyright (C) 2017 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:748.e1 / 748.e8
页数:8
相关论文
共 18 条
[1]  
Becton J L, 1998, Am J Orthop (Belle Mead NJ), V27, P619
[2]  
Burke E F, 1998, Tech Hand Up Extrem Surg, V2, P248, DOI 10.1097/00130911-199812000-00004
[3]  
Chhabra A, 2001, CLIN ORTHOP RELAT R, P318
[4]   COMPLICATIONS OF COLLES FRACTURES [J].
COONEY, WP ;
DOBYNS, JH ;
LINSCHEID, RL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (04) :613-619
[5]  
Dahl Jason, 2015, Hand (N Y), V10, P657, DOI 10.1007/s11552-015-9762-y
[6]   Bridge plating of distal radius fractures - The Harborview method [J].
Hanel, Douglas P. ;
Lu, Thomas S. ;
Weil, Wayne M. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (445) :91-99
[7]   Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture? a biomechanical study [J].
Kandemir, Utku ;
Matityahu, Amir ;
Desai, Rohan ;
Puttlitz, Christian .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (09) :605-610
[8]   Functional Outcomes Following Bridge Plate Fixation for Distal Radius Fractures [J].
Lauder, Alexander ;
Agnew, Sonya ;
Bakri, Karim ;
Allan, Christopher H. ;
Hanel, Douglas P. ;
Huang, Jerry I. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (08) :1554-1562
[9]   Risk of Tendon Entrapment Under a Dorsal Bridge Plate in a Distal Radius Fracture Model [J].
Lewis, Sarah ;
Mostofi, Amir ;
Stevanovic, Milan ;
Ghiassi, Alidad .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (03) :500-504
[10]   Use of the Hoffman 2 compact external fixator in the treatment of redisplaced unstable distal radial fractures [J].
McQueen, MM ;
Simpson, D ;
Court-Brown, CM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (07) :501-505