The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults

被引:168
作者
Dark, PM
Singer, M
机构
[1] Univ Manchester, Hope Hosp, Dept Intens Care Med, Injury Repair & Rehabil Res Grp, Salford M6 8HD, Lancs, England
[2] UCL, Dept Med, London WC1E 6BT, England
[3] UCL, Wolfson Inst Biomed Res, London WC1E 6BT, England
关键词
cardiac output; trans-esophageal Doppler ultrasonography; esophageal Doppler monitoring;
D O I
10.1007/s00134-004-2430-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine the validity of the esophageal Doppler monitor (EDM) and echo-esophageal Doppler (Echo-ED) in measuring cardiac output in the critically ill. Design: Systematic search of relevant international literature and data synthesis. Search strategy: Literature search (1989-2003) using Ovid interface to Medline, Embase and Cochrane databases aimed at finding studies comparing EDM or Echo-ED cardiac output with that derived from simultaneous pulmonary artery thermodilution (PAC(TD)) with Bland Altman measures of validity. Patients: Critically ill adults in operating departments or intensive care units. Data synthesis: Summary validity measures synthesized from Bland Altman analyses included pooled median bias and the median percentage of clinical agreement (PCA) derived from the limits of agreement. Main results: Eleven validation papers for EDM (21 studies) involving 314 patients and 2,400 paired measurements. The pooled median bias for PAC(TD) versus EDM was 0.19 l/min (range -0.69 to 2.00 l/min) for cardiac output (16 studies), and 0.6% (range 0-2.3%) for changes in cardiac output (5 studies). The pooled median percentage of clinical agreement for PAC(TD) versus EDM was 52% (interquartile range 42-69%) for cardiac output and 86% (interquartile range 55-93%) for changes in cardiac output. These differences in PCA were significant (p=0.03 Mann-Whitney) for bolus PAC(TD) as the clinical "gold standard". We found an insufficient number of studies (2 papers) to assess the validity of Echo-ED. Conclusions:The esophageal Doppler monitor has high validity (no bias and high clinical agreement with pulmonary artery thermodilution) for monitoring changes in cardiac output.
引用
收藏
页码:2060 / 2066
页数:7
相关论文
共 23 条
[1]   Haemodynamic measurements (Continuous cardiac output and systemic vascular resistance) in critically ill patients: Transoesophageal Doppler versus continuous thermodilution [J].
Baillard, C ;
Cohen, Y ;
Fosse, JP ;
Karoubi, P ;
Hoang, P ;
Cupa, M .
ANAESTHESIA AND INTENSIVE CARE, 1999, 27 (01) :33-37
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Minimally invasive hemodynamic monitoring for the intensivist: Current and emerging technology [J].
Chaney, JC ;
Derdak, S .
CRITICAL CARE MEDICINE, 2002, 30 (10) :2338-2345
[4]   Cardiac output during liver transplantation [J].
Colbert, S ;
O'Hanlon, DM ;
Duranteau, J ;
Ecoffey, C .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (02) :133-138
[5]   Measurement of cardiac output after cardiac surgery by a new transesophageal Doppler device [J].
Jaeggi, P ;
Hofer, CK ;
Klaghofer, R ;
Fodor, P ;
Genoni, M ;
Zollinger, A .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (02) :217-220
[6]   A comparison of the use of transoesophageal Doppler and thermodilution techniques for cardiac output determination [J].
Keyl, C ;
Rodig, G ;
Lemberger, P ;
Hobbhahn, J .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1996, 13 (02) :136-142
[7]   CONTINUOUS MEASUREMENT OF CARDIAC-OUTPUT DURING AORTIC CROSS-CLAMPING BY THE ESOPHAGEAL DOPPLER MONITOR ODM-1 [J].
KLOTZ, KF ;
KLINGSIEK, S ;
SINGER, M ;
WENK, H ;
ELEFTHERIADIS, S ;
KUPPE, H ;
SCHMUCKER, P .
BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 (06) :655-660
[8]   The peri-operative use of the oesophageal Doppler monitor in patients undergoing coronary artery revascularisation - A comparison with the continuous cardiac output monitor [J].
Krishnamurthy, B ;
McMurray, TJ ;
McClean, E .
ANAESTHESIA, 1997, 52 (07) :624-629
[9]  
Laupland KB, 2002, CAN J ANAESTH, V49, P393, DOI 10.1007/BF03017329
[10]   Oesophageal Doppler monitoring overestimates cardiac output during lumbar epidural anaesthesia [J].
Leather, HA ;
Wouters, PF .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 86 (06) :794-797